12
item
Board
inscription
Description of connection
item
Board
inscription
Description of connection
1
2
3
4
5
6
7
8
9
10
11
KH PE
BR PE
NE PE
NE bl
S1 brn
S1 bl
BR brn
BR bl
BR schw
PU bl
PU brn
Protective conductor ball valve
Protective conductor pump controller
Protective conductor mains connection
N- Mains connection 230V~, blue
Selection Switch brown
Selection Switch blue
L1-Pump controller brown
N-Pump controller blue
Pump controller black
N-Pump blue
L1-Pump brown
12
13
14
15
16
17
18
19
20
21
22
SS PE
PU PE
LP PE
NE br
SS brn
SS bl
KH schw
KH grün
KH rt
LP bl
LP brn
Protective conductor floating switch
Protective conductor pump
Protective conductor charge pump
L1-Mains connection 230 V~, brown
Floating switch brown
Floating switch blue
N-Ball valve black
L1-Ball valve green
L1-Ball valve red
N-Charge pump blue
L1-Charge pump brown
Overview of the cable connections
The mode selection switch is wired with a flat pin plug.
Loosen the screws to change the condenser and take off the
cable-end eyelet ring.
Attention:
Do not let the nuts fall down into the inner coil of the motor!
Note:
When connecting a new condenser the polarity is not
important.