33
6.9 Sludge pump
Article:
Operating voltage:
Dimension:
Max. pressure:
Max. flow rate:
Pipe connection:
Cable length:
Weight:
VIP130/6
230 V AC/ 50 Hz, 4A
Ø165 x 290 mm (0.7 x 11.4 “)
6 m (19.7 ft)
120 L/min (32 GPM)
1 ¼ “, hose bush Ø 25mm (9.8 “)
10 m (32.8 ft)
4 kg (8.8 lbs)
DRENOX 160/8
230 V AC/ 50 Hz, 2.2A
Ø177 x 300 mm (0.7 x 11.8 “)
8 m (26.2 ft)
150 L/min (37 GPM)
1 ¼ “, hose bush
10 m (32.8 ft)
6.5 kg (14.3 lbs)
Installation note:
Connection of sludge pumps to the AQUALOOP controller:
- Cut the plug off the end of the cable
- Strip the protective sheath back from the cut end by 6 cm (2.4 “)
- Strip the green/yellow, blue and brown cables back from their ends by 2 cm (0.8 “)
- Install cables as per the instructions in section 6.1
Содержание AQUALOOP GW 10800
Страница 10: ...9 Tab Official listing https www intewa de en applications rain greywater harvesting greywaterrecycling...
Страница 12: ...11 Fig AQUALOOP System 1200 L day 317 GPD Fig AQUALOOP System 1800 L day 476 GPD...
Страница 13: ...12 Fig AQUALOOP System 3600 L day 952GPD Fig AQUALOOP System 5400 L day 1428 GPD...
Страница 37: ...36 Fig Electrical connection plan upper pump lower pump...
Страница 39: ...38 Fig Control cabinet of multiple membrane station controller...
Страница 42: ...41 7 1 3 Expansion membrane station controller Fig Control cabinet of expansion controller...
Страница 89: ...88 Designed and provided by INTEWA GmbH or to be separately approved alternative...
Страница 90: ...89 INTEWA GmbH Version 1 1 a Subject to technical changes...