background image

Specification: 120 Volt, 11 Amp 50/60Hz, Weight 8 lb

: d

Recessed into Wood Surface Installation:

Parts List:

Depending on model

Paper Template # W601 or # B040

Note:

We recommend that vacuum cleaner be mounted against one side of a 2X4 wall stud.

2 dry-wall anchors, 1 red push pin

Paper templates: #W601( #B040), #W600

4 painted screws

3 wire connectors with CM & F units only

2 high filtration bags

Disconnect all electrical power to the wall area before installing!

Do not drill near studs where electrical cable may be secured to studs adjacent to receptacles.

#Y05

CM120 in-wall installation

CM120 (removed cord) and F120 recessed installation only

etaching the power cord from your CM120 vacuum

WARNING: Electrical connections should be made by a qualified electrician

a)

Open the 2-3/4 x 1-3/8 side cover ( lower right side of unit) and pull the wires through the opening.

b)

Disconnect the wire connectors that are attached to the cord and also pull the green ground wire out. Leave

wires as long as possible.

c)

around the electric cord

and remove the cord.

d)

You are now ready for the in-wall installation.

(see Fig.: B)

(see Fig.: B)

Open the Romex clamp

at the bottom side of the unit

GROUNDING INSTRUCTIONS for CM120 and F120 ONLY, WHEN PERMANENTLY WIRED
This appliance must be connected to a grounded metal, permanent wiring system; or an
equipment-grounding conductor must be run with the circuit conductors and connected

to the equipment-grounding terminal or lead on the appliance.

WARNING:

The four mounting holes in the outer corners of the flange of the Vacuum Cleaner must be drilled
from the back of the unit with a 3/16” drill bit when the unit is to be recessed into a wall.

Step 2.

Step 3.

Step 4.

-

.

Step 5.

Step 6.

Step 7.

a

Step 8.

Step 9.

To reach with the vacuum hose as far as possible, choose a wall or surface that is centrally located and has an
electrical outlet or switch from a 16 amp circuit breaker. Make sure the wall is hollow and there are no pipes or
other obstructions in the section you choose.

Locate a space between the mounting stud and the next stud over. Make sure an electrical outlet box, a switch or

wires from a circuit breaker cable are between the studs and easy to reach from the vacuum cleaners access hole.

Tape the template against the wall at a comfortable operating height (or a minimum of 6 inches off the floor) either

at the edge of the 2X4 (use the vertical cut-out line from the template and align with the edge of the 2X4) or
somewhere in between the studs.

Refer to the paper template #W601 or B040 for the cut out

Use only 2 of the 4 anchors when installing against a 2X4. Use all 4 anchors when installing somewhere between

the studs.

Install 14 or 16 gage AWG, 300V minimum Romex cable (use wires rated for at least 95C) from the electrical power
supply and pull the power cable through the wall cut-out.

Same procedure as above, but do not use the drywall anchors. Pre-drill the 4 outer holes 3/32 dia. and secure
vacuum cleaner with the 4 painted screws.

Recessed Installation into ½ inch thick Drywall:

TIP:

Step 1

b

d

black to black white to white

green

bare ground conductor

e

Drywall installation: with a 3” dia. hole saw, cut a hole first and check for obstructions! It is easier to

re-plaster the 3” dry-wall slug than a large cut-out if you do encounter an obstruction.

The vacuum cleaner can be mounted to the side of a 2X4 wall stud or in between 2 studs. No electrical

switches or outlet should be on the installation side when mounted to a 2X4.

After inserting the anchors insert the red key-pin and push hard to toggle the anchor open behind the

dry-wall, remove red key.

) Open the 2 3/4" x 1 3/8" side cover and pull the 3 inside wires through the opening.

) Insert your 120 volt power supply cable through the Romex clamp and out of the side opening.

) With 3 wire nuts connect

,

and

to

wires.

) Tighten the Romex clamp and replace the side cover.

Slide the unit, bottom first, into the opening and secure with the four painted screws. If installed against a 2X4

use 2 screws for the 2X4 and 2 screws for the 2 anchors. Do not over-tighten.

Check to be sure dust bag and motor filter (under dust bag) are in place.

4

Содержание CM-120

Страница 1: ...anual must be read and understood before installation adjustment service or maintenance is performed This unit should be installed by a qualified technician Modification of this product can be extreme...

Страница 2: ...ned without damage to the unit For service call your local authorized service dealer or InterVac Design s Customer Care Center SAVE THESE INSTRUCTIONS 2 LIMITED WARRANTY LIMITS AND EXCLUSIONS InterVac...

Страница 3: ...bove the floor Carefully remove template from the wall and place it into the operating manual for future references Attach the enclosed 8 screws to the wall as marked on the template Keep the screw he...

Страница 4: ...tions in the section you choose Locate a space between the mounting stud and the next stud over Make sure an electrical outlet box a switch or wires from a circuit breaker cable are between the studs...

Страница 5: ...leaner push the switch to the O position 1 Remove door and dust bag 2 Reach into the cavity towards the bottom of the vacuum cleaner and remove the motor filter 3 Replace the filter with a new filter...

Страница 6: ...ust filter should be checked and washed lift the hose up on both ends and dispense some liquid detergent into both ends with a garden hose holding both ends still up fill with water shake hose up and...

Страница 7: ...erves the right to make improvements and modifications without notice DUST BAGS PART Y05 5 5 pack high filtration bags for Models H F CM PART Y06 5 5 pack high filtration bags for Models RM RMG PART Y...

Страница 8: ...10...

Отзывы: