Intertherm BM42HCD-BL Скачать руководство пользователя страница 13

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

13

Figure 34

A

1

C

1

B

1

B

2

C

2

A

2

A

1

C

1

B

1

B

2

C

2

A

2

Figure 35

Chimney

Section

Joints

No. 8 x 1/2" SMS

Screws Required At

Ever

y Joint Past 6'

No Screws Required In

Joints For First 6' of Offset

4'

6'

A

B

FTF8-ES30

Number of FTF8

A

B

Offset

Height

Offset/Return

FTF8-S4

Chimney Sections

Offset

Height

(Inches)

(Inches)

Elbow Set

Stabilizer

12"

18"

36"

48"

(mm)

(mm)

4

15

³⁄₄

1

0

0

0

0

0

102

400

9

24

¹⁄₂

1

0

1

0

0

0

229

622

12

29

³⁄₄

1

0

0

1

0

0

305

756

14

¹⁄₄

33

¹⁄₂

1

0

2

0

0

0

362

851

17

¹⁄₄

38

¹⁄₂

1

0

1

1

0

0

438

978

20

¹⁄₄

43

³⁄₄

1

0

0

2

0

0

514

1111

21

45

¹⁄₄

1

0

0

0

1

0

533

1149

22

¹⁄₄

47

¹⁄₂

1

0

2

1

0

0

565

1207

25

¹⁄₄

52

¹⁄₂

1

0

1

2

0

0

641

1334

26

¹⁄₄

54

¹⁄₄

1

0

1

0

1

0

667

1378

27

55

³⁄₄

1

0

0

0

0

1

686

1416

28

¹⁄₄

57

³⁄₄

1

0

0

3

0

0

718

1467

29

¹⁄₄

59

¹⁄₄

1

0

0

1

1

0

743

1505

31

¹⁄₄

63

1

0

2

0

1

0

794

1600

32

¹⁄₄

64

¹⁄₂

1

0

1

0

0

1

819

1638

34

¹⁄₄

68

¹⁄₄

1

0

1

1

1

0

870

1734

35

¹⁄₄

69

³⁄₄

1

0

0

1

0

1

895

1772

37

¹⁄₄

73

¹⁄₄

1

0

0

2

1

0

946

1861

38

¹⁄₄

75

1

0

0

0

2

0

972

1905

39

¹⁄₄

77

1

0

2

1

1

0

997

1956

41

¹⁄₂

80

¹⁄₂

1

0

1

4

0

0

1054

2045

43

¹⁄₄

83

³⁄₄

1

0

1

0

2

0

1099

2127

44

¹⁄₄

85

¹⁄₄

1

0

0

0

1

1

1124

2165

45

¹⁄₄

87

¹⁄₂

1

0

0

3

1

0

1149

2223

46

¹⁄₄

89

1

0

0

1

2

0

1175

2261

48

¹⁄₄

91

¹⁄₂

1

0

2

0

2

0

1226

2324

49

¹⁄₄

94

¹⁄₄

1

0

1

0

1

1

1251

2394

50

¹⁄₄

95

³⁄₄

1

0

0

0

0

2

1276

2432

51

¹⁄₄

97

³⁄₄

1

0

1

1

2

0

1302

2483

54

¹⁄₄

103

1

0

0

2

2

0

1378

2616

55

¹⁄₄

104

¹⁄₂

1

0

1

0

0

2

1403

2654

56

¹⁄₂

106

¹⁄₂

1

0

2

1

2

0

1435

2705

58

¹⁄₄

109

³⁄₄

1

0

0

1

0

2

1480

2788

62

¹⁄₂

116

³⁄₄

1

1

1

0

3

0

1588

2965

65

¹⁄₂

122

1

1

0

1

3

0

1664

3099

67

³⁄₄

125

¹⁄₂

1

1

2

0

3

0

1721

3188

69

¹⁄₂

128

³⁄₄

1

1

0

0

1

2

1765

3270

70

³⁄₄

130

³⁄₄

1

1

1

1

3

0

1797

3321

73

³⁄₄

136

1

1

0

2

3

0

1873

3454

75

¹⁄₂

139

1

1

0

0

0

3

1918

3531

79

³⁄₄

146

¹⁄₄

1

1

1

0

4

0

2026

3715

80

³⁄₄

148

1

1

1

0

0

3

2051

3759

82

³⁄₄

151

¹⁄₂

1

1

0

1

4

0

2102

3848

83

¹⁄₂

153

1

1

0

1

0

3

2121

3886

FTF8 OFFSET ELEVATION CHART

Содержание BM42HCD-BL

Страница 1: ...tion Do not alter or modify the fireplace or its components under any circumstances Any modification or alteration of the fireplace system including but not limited to the fireplace chimney components...

Страница 2: ...our fireplace DO NOT burn wood products with synthetic binders like plywood Never burn treated construction lumber or scraps These woods burn excessively hot and may contain chemicals used to treat in...

Страница 3: ...ional Fire Protection Standard for chimneys fireplaces and solid fuel burning appliances NFPA 211 and in accordance with codes such as the BOCA Basic National Codes the Standard Me chanicalCodeandtheU...

Страница 4: ...nimum system height chart WARNING DO NOT PACK OR FILL RE QUIRED AIR SPACES WITH INSULATION OR OTHER MATERIAL NO MATERIAL IS ALLOWED IN THESE AREAS SECURE THE AIRSPACE AROUND THE CHIMNEY WITH THE FIRES...

Страница 5: ...place as illustrated Figures5 6 and 7 The safety strips should overlap for continual coverage of the floor Note Safety strips are not required when fire place rests on a noncombustible surface 1 Posit...

Страница 6: ...covering such as drywall is to be attached to the rear wall then the 21 549 mm must be measured from the drywall surface It is important that this dimension be 21 549 mm or greater If the appliance is...

Страница 7: ...n J D A E F Back Wall of Chase Enclosure Including Finising Materials if any Rough Framing Face Unfinished Shown Framing Dimensions A 46 1175 mm B 43 1105 mm C 33 838 mm D 17 445 mm E 76 1937 mm F 38...

Страница 8: ...osition appropriate thimble firestop spacer combination at ceiling and nail tempo rarily with two 2 8d nails or equivalent fasten ers seeFigures19 20and21 Useonefastener onoppositesidestoholdthimble f...

Страница 9: ...roof in true vertical position Locking Tabs Lances WARNING DO NOT ALLOW INSULATING MATERIALS TO BE BLOWN INTO THE SPACE INSIDE THE THIMBLE AND THE CHIMNEY TO DO SO COULD RESULT IN A FIRE HAZARD Figure...

Страница 10: ...ngs adjoining roof lines adverse wind conditions etc may require a taller chimney should the fireplace not draft properly Figure 31 Less Than 10 3 Min 2 Min 10 3 Min Locking Band Mastic Or Roof Caulki...

Страница 11: ...ections of chimney may be used between but do not exceed 20 in total length between elbows If sections of pipe exceed 10 between elbows a chimney stabilizer must be used at the midpoint see Figure 33...

Страница 12: ...mber Of FTF8 Height Of Chimney Only Chimney Lengths Chimney Only Inches Feet Inches 12 18 36 48 MM M Height Of Number Of FTF8 Height Of Chimney Only Chimney Lengths Chimney Only Inches Feet Inches 12...

Страница 13: ...0 0 718 1467 29 59 1 0 0 1 1 0 743 1505 31 63 1 0 2 0 1 0 794 1600 32 64 1 0 1 0 0 1 819 1638 34 68 1 0 1 1 1 0 870 1734 35 69 1 0 0 1 0 1 895 1772 37 73 1 0 0 2 1 0 946 1861 38 75 1 0 0 0 2 0 972 190...

Страница 14: ...himney Section S FTF8 E30 Return Elbow FTF8 30 Offset Elbow B A Part of Offset Return Package Model FTF8 ES30 INSTALLING OFFSETS First review the Offset Elevation Chart and Figure 37 for reference Ste...

Страница 15: ...be caulked where it meets the black metal facing of the fireplace to avoid cold air intrusion Use noncombustible caulking material only on fireplace facing to seal Also the outside air inlet duct shou...

Страница 16: ...o frame your fireplace after it is positioned and the chimney is in stalled Frame enclosure for chimney and fire place with materials of suitable grade and size asdictatedbytheprevailingconstructionss...

Страница 17: ...e equal to or greater than R r x TL 1 19 x 1 1 19 If it is desired to elevate a marble hearth exten sion to a level of 5 or more above the floor surface What combination of noncombustible materials ca...

Страница 18: ...le brick etc may overlap the black front facing Do not extend these materials beyond the black facing and into the firebox area Be sure not to interfere with the installation and operation of glass do...

Страница 19: ...NS NOT TO SCALE 19 Termination 90L81 FBTM Forced Air Blower Kit 36L32 BFK36 Stabilizer 63L25 FTF8 S4 Firestop Spacer 30 63L30 F8FS30 Firestop Spacer Flat 63L29 F8FS INSTALLATION COMPONENTS Cold Climat...

Страница 20: ...V A 01 2003 The manufacturer reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products Consult your loc...