Roof Ridge

120

°

Step 10. Using a FBTM Termination:

1.

 Hold the FBTM over top of last chimney

section (

Figure 30 ).

2.

 Center inner slip section in inner flue pipe-

slip down.

Figure 29

Figure 30

Figure 31

3.

 Center outer locking section over outer flue

pipe. Push down until locking tabs are firmly
engaged.

4.

 Pull up slightly on FBTM to ensure locking

joint has firmly engaged.

Note:

 It is recommended that all exterior ex-

posed metal fireplace components; such as
terminations, flashings, storm collars and/or
flue be painted with a premium quality, high
temperature, rust preventative paint designed
for metal. This is especially important when
installations are made in abnormally adverse or
corrosive environments; such as near lakes,
oceans or in areas with consistently high hu-
midity conditions. Consult the paint manufac-
turers instructions for proper preparation and
application.

TEN FOOT RULE SUMMARY

The minimum chimney height above the roof
and/or to adjacent walls and buildings is speci-
fied by all major building codes.

If the horizontal distance from the peak of the
roof is less then 10', the top of the chimney
must be at least 2' above the peak of the roof.

If the horizontal distance from the chimney
edge to the peak of the roof is more than 10' a
chimney height reference point is established
on the roof surface 10' horizontally from the
chimney edge.  The top of the chimney must be
at least 2' above this reference point. In all
cases, the chimney cannot be less then 3'
above the roof at the edge of the chimney.

The 2' in 10' rule is necessary in the interest of
safety but does not ensure smoke-free opera-
tion. Trees, buildings, adjoining roof lines,
adverse wind conditions, etc., may require a
taller chimney should the fireplace not draft
properly (

Figure 31 ).

Less Than 10'

3'

Min

2' Min.

10'

3'

Min

Locking Band

Mastic

Or Roof

Caulking

CTD

Termination

Chimney

Figure 27

Step 8.

 The standard FireCraft Technologies'

FTF8 roof flashing assemblies include a storm
collar. Slide the storm collar over outer chim-
ney, rest on flashing spacers and align with top
surface of flashing. Insert tab in slot, pull tight
and bend tab back over slot. Seal storm collar
to outer chimney with roof caulking or mastic
around entire circumference of pipe. Also add
extra roof caulking to the tab/slot area to seal
completely against water penetration (

Figure

28 ). Check all joints very carefully to ensure
no water intrusion can take place.

Figure 28

Note:

 If chimney extends more than 8' above

roof surface, guy wires are also recommended.
Use three (3) guy wires, attach to locking band
assembly, extend and secure to roof in a
triangular pattern (Figure 29 ). Guy wires are
not supplied by the manufacturer.

Step 9.  

FTF locking bands, Model FLB, may be

required if the chimney extends too high above
the roof flashing. As a general rule, if the
chimney extends more than 6' above the roof
flashing, the use of locking bands is advisable
to strengthen the chimney assembly.  Align
the locking band at the chimney joint. Locking
bands wrap around pipe joints equally cover-
ing the joints of both pipe sections. Use the nut
provided and TIGHTEN snugly. Do not over-
tighten as this might damage the chimney
section (

refer to Figure 23 ).

Step 7.

 Secure flashing by nailing along the

perimeter into roof using 8d nails or equivalent
fasteners. If shingled roof, slide upper end and
sides of roof flashing under shingles (trim if
necessary), seal the top and both sides of the
flashing to the roof with roof caulking. Cover
fastener heads with roof caulking (

Figure 27 ).

Содержание BM42HCD-BL

Страница 1: ...tion Do not alter or modify the fireplace or its components under any circumstances Any modification or alteration of the fireplace system including but not limited to the fireplace chimney components...

Страница 2: ...our fireplace DO NOT burn wood products with synthetic binders like plywood Never burn treated construction lumber or scraps These woods burn excessively hot and may contain chemicals used to treat in...

Страница 3: ...ional Fire Protection Standard for chimneys fireplaces and solid fuel burning appliances NFPA 211 and in accordance with codes such as the BOCA Basic National Codes the Standard Me chanicalCodeandtheU...

Страница 4: ...nimum system height chart WARNING DO NOT PACK OR FILL RE QUIRED AIR SPACES WITH INSULATION OR OTHER MATERIAL NO MATERIAL IS ALLOWED IN THESE AREAS SECURE THE AIRSPACE AROUND THE CHIMNEY WITH THE FIRES...

Страница 5: ...place as illustrated Figures5 6 and 7 The safety strips should overlap for continual coverage of the floor Note Safety strips are not required when fire place rests on a noncombustible surface 1 Posit...

Страница 6: ...covering such as drywall is to be attached to the rear wall then the 21 549 mm must be measured from the drywall surface It is important that this dimension be 21 549 mm or greater If the appliance is...

Страница 7: ...n J D A E F Back Wall of Chase Enclosure Including Finising Materials if any Rough Framing Face Unfinished Shown Framing Dimensions A 46 1175 mm B 43 1105 mm C 33 838 mm D 17 445 mm E 76 1937 mm F 38...

Страница 8: ...osition appropriate thimble firestop spacer combination at ceiling and nail tempo rarily with two 2 8d nails or equivalent fasten ers seeFigures19 20and21 Useonefastener onoppositesidestoholdthimble f...

Страница 9: ...roof in true vertical position Locking Tabs Lances WARNING DO NOT ALLOW INSULATING MATERIALS TO BE BLOWN INTO THE SPACE INSIDE THE THIMBLE AND THE CHIMNEY TO DO SO COULD RESULT IN A FIRE HAZARD Figure...

Страница 10: ...ngs adjoining roof lines adverse wind conditions etc may require a taller chimney should the fireplace not draft properly Figure 31 Less Than 10 3 Min 2 Min 10 3 Min Locking Band Mastic Or Roof Caulki...

Страница 11: ...ections of chimney may be used between but do not exceed 20 in total length between elbows If sections of pipe exceed 10 between elbows a chimney stabilizer must be used at the midpoint see Figure 33...

Страница 12: ...mber Of FTF8 Height Of Chimney Only Chimney Lengths Chimney Only Inches Feet Inches 12 18 36 48 MM M Height Of Number Of FTF8 Height Of Chimney Only Chimney Lengths Chimney Only Inches Feet Inches 12...

Страница 13: ...0 0 718 1467 29 59 1 0 0 1 1 0 743 1505 31 63 1 0 2 0 1 0 794 1600 32 64 1 0 1 0 0 1 819 1638 34 68 1 0 1 1 1 0 870 1734 35 69 1 0 0 1 0 1 895 1772 37 73 1 0 0 2 1 0 946 1861 38 75 1 0 0 0 2 0 972 190...

Страница 14: ...himney Section S FTF8 E30 Return Elbow FTF8 30 Offset Elbow B A Part of Offset Return Package Model FTF8 ES30 INSTALLING OFFSETS First review the Offset Elevation Chart and Figure 37 for reference Ste...

Страница 15: ...be caulked where it meets the black metal facing of the fireplace to avoid cold air intrusion Use noncombustible caulking material only on fireplace facing to seal Also the outside air inlet duct shou...

Страница 16: ...o frame your fireplace after it is positioned and the chimney is in stalled Frame enclosure for chimney and fire place with materials of suitable grade and size asdictatedbytheprevailingconstructionss...

Страница 17: ...e equal to or greater than R r x TL 1 19 x 1 1 19 If it is desired to elevate a marble hearth exten sion to a level of 5 or more above the floor surface What combination of noncombustible materials ca...

Страница 18: ...le brick etc may overlap the black front facing Do not extend these materials beyond the black facing and into the firebox area Be sure not to interfere with the installation and operation of glass do...

Страница 19: ...NS NOT TO SCALE 19 Termination 90L81 FBTM Forced Air Blower Kit 36L32 BFK36 Stabilizer 63L25 FTF8 S4 Firestop Spacer 30 63L30 F8FS30 Firestop Spacer Flat 63L29 F8FS INSTALLATION COMPONENTS Cold Climat...

Страница 20: ...V A 01 2003 The manufacturer reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products Consult your loc...

Отзывы: