Intertherm BDELUXE 36 M36HC Скачать руководство пользователя страница 18

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

18

Termination

90L81

FBTM

Forced Air Blower Kit

36L32

BFK36

63L10

FTF8-12

63L13

FTF8-18

63L14

FTF8-36

Chimney Section

63L15

FTF8-48

Storm Collar
12 Pack

94L77

FSC

0-6/12

63L38

F8F6

Flashing

6/12-12/12

63L39

F8F12

Locking Band

63L60

FLB

Shipping Weight

175 lbs.

INSTALLATION COMPONENTS

The following items are available for use in the
installation of this appliance.

Thimble Extension 26"

91L46

F8-TE26

Stabilizer

63L25

FTF8-S4

Firestop Spacer (30

°

)

63L30

F8FS30

Firestop Spacer (Flat)

63L29

F8FS

Offset/ Return
Package (30

°

)

63L22

FTF8-ES30

FINISH TO YOUR TASTE

There are a wide variety of “finished looks” for
these fireplaces, from formal wall decor with
elaborate mantels to rustic wood paneling or
warm brick facings.

Only noncombustible materials like stone, tile,
brick, etc., may overlap the black front facing.
Do not extend these materials beyond the black
facing and into the firebox area. Be sure not to
interfere with the installation and operation of
glass doors or block the upper or lower grilles.
Seal all joints between the black facing and wall
surrounds to prevent air intrusion. Use non-
combustible caulking material only to seal the
black metal facing to the surround material on
the finished wall.

Combustible materials may project beyond the
sides of the fireplace opening as long as they
are kept within the shaded areas illustrated in
Figure 48.

Figure 48

12"

Min. Distance To

Unprotected Side Wall

7"

45

°

Combustible

Materials

Allowed In

Shaded Area

“Safe Zone”

7"

1"

Min. Distance To

Protected Side Wall

Fireplace

12"

Adjustable Firestop/Thimble

HO325

FM8-AT1

Adjustable Chimney Pipe Kits

HO323

FM8-PK1

Содержание BDELUXE 36 M36HC

Страница 1: ...ore beginning your installation Do not alter or modify the fireplace or its components under any circumstances Any modification or alteration of the fireplace system including but not limited to the f...

Страница 2: ...our fireplace DO NOT burn wood products with synthetic binders like plywood Never burn treated construction lumber or scraps These woods burn excessively hot and may contain chemicals used to treat in...

Страница 3: ...nal Fire Protection Standard for chimneys fireplaces and solid fuel burning appliances NFPA 211 and in accordance with codes such as the BOCA Basic National Codes the Standard Me chanicalCodeandtheUni...

Страница 4: ...eight chart WARNING DO NOT PACK OR FILL RE QUIRED AIR SPACES WITH INSULATION OR OTHER MATERIAL NO MATERIAL IS ALLOWED IN THESE AREAS SECURE THE AIRSPACE AROUND THE CHIMNEY WITH THE FIRESTOP THIMBLE BE...

Страница 5: ...ce as illustrated Figures5 6 and 7 The safety strips should overlap for continual coverage of the floor Note Safety strips are not required when fire place rests on a noncombustible surface 1 Position...

Страница 6: ...es 10 through 13 on page 7 IMPORTANT UNDER NO CIRCUMSTANCES CAN THE FIREPLACE TOP SPACERS FIGURE 9 BE REMOVED OR MODIFIED NOR MAY YOU NOTCH THE HEADER TO FIT AROUND OR BE INSTALLED LOWER THAN THE SPAC...

Страница 7: ...m 635 mm Note All framing dimensions calcu lated for 1 2 dry wall at the fireplace face Ifsheathingthechaseorfinish ing with other thickness materials calculations will need to be made Perpendicular t...

Страница 8: ...t directly adjacent to the flange INSTALLING THE CHIMNEY SYSTEM Step 1 Before continuing check the operation of the damper as described on page 4 refer to Figure 2 Step 2 Using standard construction f...

Страница 9: ...agement Check vertical alignment of chimney so that it projects from the roof in true vertical position Locking Tabs Lances Figure 21 Figure 24 Figure 22 FireCraft chimney sections do not need to be s...

Страница 10: ...gs adjoining roof lines adverse wind conditions etc may require a taller chimney should the fireplace not draft properly Figure 31 Less Than 10 3 Min 2 Min 10 3 Min Locking Band Mastic Or Roof Caulkin...

Страница 11: ...ections of chimney may be used between but do not exceed 20 in total length between elbows If sections of pipe exceed 10 between elbows a chimney stabilizer must be used at the midpoint see Figure 33...

Страница 12: ...mber Of FTF8 Height Of Chimney Only Chimney Lengths Chimney Only Inches Feet Inches 12 18 36 48 MM M Height Of Number Of FTF8 Height Of Chimney Only Chimney Lengths Chimney Only Inches Feet Inches 12...

Страница 13: ...0 0 718 1467 29 59 1 0 0 1 1 0 743 1505 31 63 1 0 2 0 1 0 794 1600 32 64 1 0 1 0 0 1 819 1638 34 68 1 0 1 1 1 0 870 1734 35 69 1 0 0 1 0 1 895 1772 37 73 1 0 0 2 1 0 946 1861 38 75 1 0 0 0 2 0 972 190...

Страница 14: ...bow Figure 36 Figure 37 Underside Of Chimney Chimney Section S FTF8 E30 Return Elbow FTF8 30 Offset Elbow B A Part of Offset Return Package Model FTF8 ES30 INSTALLING OFFSETS First review the Offset E...

Страница 15: ...st be caulked where it meets the black metal facing of the fireplace to avoid cold air intrusion Use noncombustible caulking material only on fireplace facing to seal Also the outside air inlet duct s...

Страница 16: ...if needed Figure 43 Figure 43 Note Upper door pivot pins can also be loos ened for adjustment purposes however it is easier to loosen lower pins FIREPLACE FINISHES Mantels and Trim It is sometimes bes...

Страница 17: ...e equal to or greater than R r x TL 1 19 x 1 1 19 If it is desired to elevate a marble hearth exten sion to a level of 5 or more above the floor surface What combination of noncombustible materials ca...

Страница 18: ...aneling or warm brick facings Only noncombustible materials like stone tile brick etc may overlap the black front facing Do not extend these materials beyond the black facing and into the firebox area...

Страница 19: ...NOTE DIAGRAMS ILLUSTRATIONS NOT TO SCALE 19...

Страница 20: ...V B 04 2002 The manufacturer reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products Consult your loc...

Отзывы: