Intertherm BDELUXE 36 M36HC Скачать руководство пользователя страница 10

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

10

Roof Ridge

120

°

Step 10. Using a FBTM Termination:

1.

 Hold the FBTM over top of last chimney

section (

Figure 30 ).

2.

 Center inner slip section in inner flue pipe-

slip down.

Figure 29

Figure 30

Figure 31

3.

 Center outer locking section over outer flue

pipe. Push down until locking tabs are firmly
engaged.

4.

 Pull up slightly on FBTM to ensure locking

joint has firmly engaged.

Note:

 It is recommended that all exterior ex-

posed metal fireplace components; such as
terminations, flashings, storm collars and/or
flue be painted with a premium quality, high
temperature, rust preventative paint designed
for metal. This is especially important when
installations are made in abnormally adverse or
corrosive environments; such as near lakes,
oceans or in areas with consistently high hu-
midity conditions. Consult the paint manufac-
turers instructions for proper preparation and
application.

TEN FOOT RULE SUMMARY

The minimum chimney height above the roof
and/or to adjacent walls and buildings is speci-
fied by all major building codes.

If the horizontal distance from the peak of the
roof is less then 10', the top of the chimney
must be at least 2' above the peak of the roof.

If the horizontal distance from the chimney
edge to the peak of the roof is more than 10' a
chimney height reference point is established
on the roof surface 10' horizontally from the
chimney edge.  The top of the chimney must be
at least 2' above this reference point. In all
cases, the chimney cannot be less then 3'
above the roof at the edge of the chimney.

The 2' in 10' rule is necessary in the interest of
safety but does not ensure smoke-free opera-
tion. Trees, buildings, adjoining roof lines,
adverse wind conditions, etc., may require a
taller chimney should the fireplace not draft
properly (

Figure 31 ).

Less Than 10'

3'

Min

2' Min.

10'

3'

Min

Locking Band

Mastic

Or Roof

Caulking

FBTM

Termination

Chimney

Figure 27

Step 8.

 The standard FireCraft Technologies'

FTF8 roof flashing assemblies include a storm
collar. Slide the storm collar over outer chim-
ney, rest on flashing spacers and align with top
surface of flashing. Insert tab in slot, pull tight
and bend tab back over slot. Seal storm collar
to outer chimney with roof caulking or mastic
around entire circumference of pipe. Also add
extra roof caulking to the tab/slot area to seal
completely against water penetration (

Figure

28 ). Check all joints very carefully to ensure
no water intrusion can take place.

Figure 28

Note:

 If chimney extends more than 8' above

roof surface, guy wires are also recommended.
Use three (3) guy wires, attach to locking band
assembly, extend and secure to roof in a
triangular pattern (Figure 29 ). Guy wires are
not supplied by the manufacturer.

Step 9.  

FTF locking bands, Model FLB, may be

required if the chimney extends too high above
the roof flashing. As a general rule, if the
chimney extends more than 6' above the roof
flashing, the use of locking bands is advisable
to strengthen the chimney assembly.  Align
the locking band at the chimney joint. Locking
bands wrap around pipe joints equally cover-
ing the joints of both pipe sections. Use the nut
provided and TIGHTEN snugly. Do not over-
tighten as this might damage the chimney
section (

refer to Figure 23 ).

Step 7.

 Secure flashing by nailing along the

perimeter into roof using 8d nails or equivalent
fasteners. If shingled roof, slide upper end and
sides of roof flashing under shingles (trim if
necessary), seal the top and both sides of the
flashing to the roof with roof caulking. Cover
fastener heads with roof caulking (

Figure 27 ).

Содержание BDELUXE 36 M36HC

Страница 1: ...ore beginning your installation Do not alter or modify the fireplace or its components under any circumstances Any modification or alteration of the fireplace system including but not limited to the f...

Страница 2: ...our fireplace DO NOT burn wood products with synthetic binders like plywood Never burn treated construction lumber or scraps These woods burn excessively hot and may contain chemicals used to treat in...

Страница 3: ...nal Fire Protection Standard for chimneys fireplaces and solid fuel burning appliances NFPA 211 and in accordance with codes such as the BOCA Basic National Codes the Standard Me chanicalCodeandtheUni...

Страница 4: ...eight chart WARNING DO NOT PACK OR FILL RE QUIRED AIR SPACES WITH INSULATION OR OTHER MATERIAL NO MATERIAL IS ALLOWED IN THESE AREAS SECURE THE AIRSPACE AROUND THE CHIMNEY WITH THE FIRESTOP THIMBLE BE...

Страница 5: ...ce as illustrated Figures5 6 and 7 The safety strips should overlap for continual coverage of the floor Note Safety strips are not required when fire place rests on a noncombustible surface 1 Position...

Страница 6: ...es 10 through 13 on page 7 IMPORTANT UNDER NO CIRCUMSTANCES CAN THE FIREPLACE TOP SPACERS FIGURE 9 BE REMOVED OR MODIFIED NOR MAY YOU NOTCH THE HEADER TO FIT AROUND OR BE INSTALLED LOWER THAN THE SPAC...

Страница 7: ...m 635 mm Note All framing dimensions calcu lated for 1 2 dry wall at the fireplace face Ifsheathingthechaseorfinish ing with other thickness materials calculations will need to be made Perpendicular t...

Страница 8: ...t directly adjacent to the flange INSTALLING THE CHIMNEY SYSTEM Step 1 Before continuing check the operation of the damper as described on page 4 refer to Figure 2 Step 2 Using standard construction f...

Страница 9: ...agement Check vertical alignment of chimney so that it projects from the roof in true vertical position Locking Tabs Lances Figure 21 Figure 24 Figure 22 FireCraft chimney sections do not need to be s...

Страница 10: ...gs adjoining roof lines adverse wind conditions etc may require a taller chimney should the fireplace not draft properly Figure 31 Less Than 10 3 Min 2 Min 10 3 Min Locking Band Mastic Or Roof Caulkin...

Страница 11: ...ections of chimney may be used between but do not exceed 20 in total length between elbows If sections of pipe exceed 10 between elbows a chimney stabilizer must be used at the midpoint see Figure 33...

Страница 12: ...mber Of FTF8 Height Of Chimney Only Chimney Lengths Chimney Only Inches Feet Inches 12 18 36 48 MM M Height Of Number Of FTF8 Height Of Chimney Only Chimney Lengths Chimney Only Inches Feet Inches 12...

Страница 13: ...0 0 718 1467 29 59 1 0 0 1 1 0 743 1505 31 63 1 0 2 0 1 0 794 1600 32 64 1 0 1 0 0 1 819 1638 34 68 1 0 1 1 1 0 870 1734 35 69 1 0 0 1 0 1 895 1772 37 73 1 0 0 2 1 0 946 1861 38 75 1 0 0 0 2 0 972 190...

Страница 14: ...bow Figure 36 Figure 37 Underside Of Chimney Chimney Section S FTF8 E30 Return Elbow FTF8 30 Offset Elbow B A Part of Offset Return Package Model FTF8 ES30 INSTALLING OFFSETS First review the Offset E...

Страница 15: ...st be caulked where it meets the black metal facing of the fireplace to avoid cold air intrusion Use noncombustible caulking material only on fireplace facing to seal Also the outside air inlet duct s...

Страница 16: ...if needed Figure 43 Figure 43 Note Upper door pivot pins can also be loos ened for adjustment purposes however it is easier to loosen lower pins FIREPLACE FINISHES Mantels and Trim It is sometimes bes...

Страница 17: ...e equal to or greater than R r x TL 1 19 x 1 1 19 If it is desired to elevate a marble hearth exten sion to a level of 5 or more above the floor surface What combination of noncombustible materials ca...

Страница 18: ...aneling or warm brick facings Only noncombustible materials like stone tile brick etc may overlap the black front facing Do not extend these materials beyond the black facing and into the firebox area...

Страница 19: ...NOTE DIAGRAMS ILLUSTRATIONS NOT TO SCALE 19...

Страница 20: ...V B 04 2002 The manufacturer reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products Consult your loc...

Отзывы: