Intertec Data Systems ISOPASS Скачать руководство пользователя страница 4

www.intertec.info

Mounting Instructions Insulation adapter ISOPASS

Page 4 / 6

KMI111379595Ien-1

INTERTEC-Hess GmbH · Raffineriestr. 8 · 93333 Neustadt/Donau · Germany · 

 +49 9445 9532-0 ·   [email protected]

Addition D = suitable for DIABOX protective boxes

Insulation

Protective box

ISOPASS

Sheet metal jacket for

insulation

WDD 16/20

Impulse line

Electrical

trace heating cable

Illustration 1: 

ISOPASS sectional View

5

Installation accessories

The following are included in the standard delivery:

Piece

Name

2

Moulded part made from rigid integral poly-

urethane foam

2

Clamp made from VA spring wire

2

Bracket made from VA sheet metal

4

Plastic bolt M6 with nut

If  one  of  the  components  listed  here  is  not  included  in
the standard delivery, then please contact the manufac-
turer.

Illustration 2: 

ISOPASS installation kit

6

Installing at the Bottom of Housings

The two half-shells made from rigid integral polyurethane
foam  are  placed  around  the  impulse  line.  The  thin-wall
covering  of  the  adapter  is  cut  out  to  fit  the  diameter  of
the pipe. Both halves are held together laterally with the
two  clamps  made  from  Cr-Ni  steel.  The  insulation  ad-
apter is attached to the protective enclosure/box with the
two brackets and the plastic bolts for firm fastening.

The insulator can then link up with the conical stub of the
ISOPASS.

Illustration 3: 

Installation example at the bottom of the housing

7

Installation on insulated Housings

If  the  insulation  adapter  is  installed  on  non-insulated
standard boxes, please follow the installation instructions
under 

Installing  at  the  Bottom  of  Housings  [

}

Page  4]

or 

Installing  at  the  Side  or  at  the  Top  of  the  Housing  [

}

Page 4]

.

In the case of foam-filled boxes such as INTERTEC DI-
ABOX  or  INTERTEC  MULTIBOX,  there  are  thicker  wall
thicknesses.  To  attach  the  insulation  adapter  with  the
plastic  bolts  M6,  you  must  first  cut  holes  at  the  desig-
nated positions using a screw tap M6.

For installing on INTERTEC protective enclosure, M6 in-
sert nuts (Art. No. NNMA-M6.3-5) with a specially adap-
ted  GFK  adapter  plate  instead  of  the  plastic  bolts  must
be  ordered  separately.  Both  articles  must  be  ordered
separately.

8

Installing at the Side or at the Top of
the Housing

Additional  necessary  accessories  (not  included  in
the standard delivery): silicon sealing compound

Отзывы: