![Intertec Data Systems ISOPASS Скачать руководство пользователя страница 4](http://html1.mh-extra.com/html/intertec-data-systems/isopass/isopass_quick-start-manual_2080660004.webp)
www.intertec.info
Mounting Instructions Insulation adapter ISOPASS
Page 4 / 6
KMI111379595Ien-1
INTERTEC-Hess GmbH · Raffineriestr. 8 · 93333 Neustadt/Donau · Germany ·
+49 9445 9532-0 · [email protected]
Addition D = suitable for DIABOX protective boxes
Insulation
Protective box
ISOPASS
Sheet metal jacket for
insulation
WDD 16/20
Impulse line
Electrical
trace heating cable
Illustration 1:
ISOPASS sectional View
5
Installation accessories
The following are included in the standard delivery:
Piece
Name
2
Moulded part made from rigid integral poly-
urethane foam
2
Clamp made from VA spring wire
2
Bracket made from VA sheet metal
4
Plastic bolt M6 with nut
If one of the components listed here is not included in
the standard delivery, then please contact the manufac-
turer.
Illustration 2:
ISOPASS installation kit
6
Installing at the Bottom of Housings
The two half-shells made from rigid integral polyurethane
foam are placed around the impulse line. The thin-wall
covering of the adapter is cut out to fit the diameter of
the pipe. Both halves are held together laterally with the
two clamps made from Cr-Ni steel. The insulation ad-
apter is attached to the protective enclosure/box with the
two brackets and the plastic bolts for firm fastening.
The insulator can then link up with the conical stub of the
ISOPASS.
Illustration 3:
Installation example at the bottom of the housing
7
Installation on insulated Housings
If the insulation adapter is installed on non-insulated
standard boxes, please follow the installation instructions
under
Installing at the Bottom of Housings [
or
Installing at the Side or at the Top of the Housing [
Page 4]
In the case of foam-filled boxes such as INTERTEC DI-
ABOX or INTERTEC MULTIBOX, there are thicker wall
thicknesses. To attach the insulation adapter with the
plastic bolts M6, you must first cut holes at the desig-
nated positions using a screw tap M6.
For installing on INTERTEC protective enclosure, M6 in-
sert nuts (Art. No. NNMA-M6.3-5) with a specially adap-
ted GFK adapter plate instead of the plastic bolts must
be ordered separately. Both articles must be ordered
separately.
8
Installing at the Side or at the Top of
the Housing
Additional necessary accessories (not included in
the standard delivery): silicon sealing compound