Operating Instructions Filter ventilator FL-ExVENT

COM155769227Ien-4

Page 5 / 8

INTERTEC-Hess GmbH · Raffineriestr. 8 · 93333 Neustadt/Donau · Germany · 

 +49 9445 9532-0 ·   [email protected]

Air flow blowing out

Illustration 3: 

FL-ExVENT side view blowing out

br=brown bl=blue gn/ye=green/yellow

Ex terminal box

br

bl

gn/ye

ExVENT 30xx

PA

Illustration 4: 

ExVENT 30xx circuit diagram

6

Connection

 INFO

The device may only be connected up and secured by a
trained person, taking into account the "rated voltage"
and "rated current" specified on the nameplate.

A  fuse  corresponding  to  its  rated  voltage  (max.  3  x  IB
according to lEC 60127-2-1) or a motor protection switch
with  short-circuit  and  thermal  instantaneous  release
(setting  to  rated  current)  must  be  upstream  of  each
electric  motor.  In  the  case  of  very  low  rated  currents  of
the electric motor, the fuse with the lowest current value
according to the specified IEC-standard is sufficient. The
fuse must be housed in the associated power supply unit
or  separately  upstream.  The  fuse  rated  current  must  be
the  same  as  or  greater  than  the  specified  maximum
working  voltage  of  the  electric  motor.  The  breaking
capacity of the fuse link must be the same as or greater
than  the  maximum  short-circuit  current  expected  at  the
place of installation (normally 1500 A). A connection box
with a melting fuse can be used for example.

Additional  equipotential  bonding  is  required.  The
terminal  block  designated  for  this  purpose  has  the
ground sign.

7

Commissioning

If  the  electric  motor  was  installed  according  to  the
guidelines  specified  under  section  Installation  and
section 

Connection  [

}

Page  5]

  and  it  is  guaranteed  that

no  foreign  bodies  can  reach  the  rotating  components,
then the electric motor can be switched on.

A  thermal  safety  fuse  is  integrated  that  disconnects  the
motor from the mains for reasons of explosion protection
in  the  event  of  external  heating  or  blockage.  This  also
occurs  if  these  installation  instructions  are  not  complied
with.

We  recommend  a  thermostat  upstream  at  temperatures
ranging from 40°C.

8

Troubleshooting

Содержание FL-ExVENT

Страница 1: ...Operating Instructions Filter ventilator FL ExVENT COM155769227Ien 4 24 08 2021...

Страница 2: ...o Table of contents 1 Use 3 2 Explanation of symbols for warnings and signal words 3 3 Safety information 3 4 Technical Data 3 5 Installation 4 6 Connection 5 7 Commissioning 5 8 Troubleshooting 5 9 M...

Страница 3: ...must be adhered to are highlighted as follows DANGER DANGER This sign is warning about an extremely hazardous situation which if not heeded will lead to death or serious irreversible injury WARNING W...

Страница 4: ...2 x 252 44 Smooth the edges of the mounting cut out The FL ExVENT is inserted from the outside through the opening The clamping lugs can be perceptibly and audibly clicked into place in all four corne...

Страница 5: ...ent The fuse must be housed in the associated power supply unit or separately upstream The fuse rated current must be the same as or greater than the specified maximum working voltage of the electric...

Страница 6: ...ty fuse is triggered Device must be replaced Auxiliary fan blocked Use spacers to create space Temperature Temperature of suction medium is greater than 60 C thermal safety fuse is triggered The tempe...

Страница 7: ...OTICE Environmental damage may be caused if disposed of incorrectly Electrical scrap and electronics components are subject to hazardous waste treatment and must only be disposed of by certified speci...

Страница 8: ...e legally defined warranties and warranty periods of 24 months are applicable to our scope of supply and services You will find more detailed information in the manufacturer warranty from INTERTEC for...

Отзывы: