Intertec Data Systems FL-ExVENT Скачать руководство пользователя страница 3

www.intertec.info

Operating Instructions Filter ventilator FL-ExVENT

COM155769227Ien-4

Page 3 / 8

INTERTEC-Hess GmbH · Raffineriestr. 8 · 93333 Neustadt/Donau · Germany · 

 +49 9445 9532-0 ·   [email protected]

1

Use

The  FL-ExVENT  filter  fan  is  manufactured  according  to
Directive  2014/34/EU  and  is  used  for  the  aeration  and
ventilation  of  housings.  It  consists  of  an  encapsulated
shaded pole motor ExVENT in a stainless steel housing,
or optionally in a GFK housing, which is approved for Ex
zone  1  of  equipment  category  G  in  temperature  class
T4, and an outlet or intake filter.

The fans used have the EU type examination certificate
PTZ  18  ATEX  0050  X  and  the  IECEx  certificate  IECEx
PTZ 18.0012X .

The  motors  used  have  the  EU  type  examination
certificate PTB 10 ATEX 2023 and the IECEx certificate
IECEx PTB 11.0016X .

Siehe 

http://www.intertec.info

2

Explanation of symbols for warnings
and signal words

The  safety  information  warns  the  user  about  risks  and
provide information on how risks can be avoided.

Safety  information  can  be  found  at  the  start  of  the
chapter  before  the  instructions  which  may  lead  to  a
hazardous situation. Additional safety information can be
found at the beginning of this manual.

Safety  instructions  which  must  be  adhered  to  are
highlighted as follows:

 DANGER

DANGER

This sign is warning about an extremely hazardous
situation which, if not heeded, will lead to death or
serious irreversible injury.

 WARNING

WARNING

This sign is warning about a hazardous situation which,
if not heeded, may lead to death or serious irreversible
injury.

 CAUTION

NOTICE

This sign is warning about a hazardous situation which,
if not heeded, may lead to slight, reversible injury.

NOTICE

NOTE

It is essential to pay attention to this safety advice as you
may otherwise incur material damage.

 INFO

Important notes and useful additional information.

3

Safety information

 CAUTION

Risk of injury

There is a risk of injury on rotating and/or hot
components.

4

Technical Data

Rated voltage

max. 230 V AC

Permitted operating voltage

max. 250 V AC

Special voltages with corresponding power adjustment

and component selection are possible

Rated current (in

compliance with VDE 0298)

max 10 A

Rated output

25 W

Protection class

IEC EN 60529

IP55*

Storage temperature

- 60 to + 60°C

Max. permitted operating

ambient temperature

- 40 to + 55°C

Insulation class

H

Temperature class

T4

Motor

ExVENT 30xx L175 PA.

Rated speed

2500 rpm

Air delivery volume

300 cbm/h*

with filter only 150 cbm/h

Installation position

optional

Delivery direction O

blowing out

Delivery direction I

blowing in

Connecting cable

Silicon tube conductor,

resistant to notching and

oil,

3x 1.5 mm², Ø 8.4 mm

Содержание FL-ExVENT

Страница 1: ...Operating Instructions Filter ventilator FL ExVENT COM155769227Ien 4 24 08 2021...

Страница 2: ...o Table of contents 1 Use 3 2 Explanation of symbols for warnings and signal words 3 3 Safety information 3 4 Technical Data 3 5 Installation 4 6 Connection 5 7 Commissioning 5 8 Troubleshooting 5 9 M...

Страница 3: ...must be adhered to are highlighted as follows DANGER DANGER This sign is warning about an extremely hazardous situation which if not heeded will lead to death or serious irreversible injury WARNING W...

Страница 4: ...2 x 252 44 Smooth the edges of the mounting cut out The FL ExVENT is inserted from the outside through the opening The clamping lugs can be perceptibly and audibly clicked into place in all four corne...

Страница 5: ...ent The fuse must be housed in the associated power supply unit or separately upstream The fuse rated current must be the same as or greater than the specified maximum working voltage of the electric...

Страница 6: ...ty fuse is triggered Device must be replaced Auxiliary fan blocked Use spacers to create space Temperature Temperature of suction medium is greater than 60 C thermal safety fuse is triggered The tempe...

Страница 7: ...OTICE Environmental damage may be caused if disposed of incorrectly Electrical scrap and electronics components are subject to hazardous waste treatment and must only be disposed of by certified speci...

Страница 8: ...e legally defined warranties and warranty periods of 24 months are applicable to our scope of supply and services You will find more detailed information in the manufacturer warranty from INTERTEC for...