Numbers in [brackets] are for 50 Hz international systems. 

7

Installer’s Guide

4.  

Apply transitions or spacer as required to clear flue 

piping and to ensure the opening of the air cleaner 

matches the opening in the furnace.  

    Position the air cleaner on the return opening of the 

furnace with the air cleaner cabinet gasket against the 

furnace.  Check that the front of the air cleaner cabinet 

is facing the front of the furnace.

5.   Align the rear of the air cleaner flush with the rear of 

the indoor unit.

6.   Align the sides of the cabinet with the sides of the unit. 

7.   The front of the cabinet will NOT align flush with the 

front of the unit.

8.   Securely fasten the unit using the self-tapping sheet 

metal screws provided. See Figure 14.

9.   Reinstall the FIELD CHARGER and lock into place by 

bending one locking tab on the cabinet. See Figure 

16.

10.  Reinstall the PRE-FILTER and COLLECTION CELLS.
11.  Each COLLECTION CELL must be oriented with the 

handles toward the front.

12.  The door can be installed in 

either direction

. See 

Door Operation Section C..

NOTE:  The door has a safety switch to ensure power 

is interrupted when the door is removed. This switch 

is open when the door is removed from the cabinet. 

When the door is properly installed, an actuator tab 

located in the cabinet will close the switch, allowing 

power to the electronics.

13. 

Remove stickers (two stickers both are 5.5" x 7.5") 

from the packet and attach to furnace, air handler, or 

ductwork in a location visible to the homeowner.

14.  Demonstrate Maintenance (Section H) and Door 

 

Operation (Section C) to the homeowner.

SIDE RETURN FURNACE INSTALLATION

 

14.5" & 17.5"  MODELS ONLY

NOTE:  The 21" and  24 1/2" air cleaner cabinet 

heights require a transition between the air cleaner 

cabinet and the  Furnace in side return applications.
NOTE:  Do not install the air cleaner cabinet on the 

side of an air handler.
NOTE:  It is recommended that sheet metal turn

-

ing vanes be installed inside an elbow on ductwork 

attached to the entering airstream side of the air 

cleaner.  See Figure 9 on Page 4. 

1.   See door operation Section C. Remove the PRE-

FILTER, FIELD CHARGER, and both COLLECTION 

CELLS. Set the components aside until the cabinet 

is installed and the indoor unit is in place.

2.   Install the self-adhesive gasket material on the 

side of the air cleaner cabinet flange that will mate 

with the indoor unit. This flange has a double set of 

holes. See Figure 19

.

3.   On a protective pad, lay the indoor unit on its side.  

Position the furnace with the return air side of the 

cabinet facing up. 

4.   Align the bottom of the air cleaner cabinet 1/4" 

ABOVE the bottom of the furnace and flush with the 

rear of the furnace.

Figure 19 Side Installation Details

5.   Mark the inside of the opening in the air cleaner 

cabinet on the side of the furnace using the inside 

edge of the air cleaner cabinet as a guide. Remove 

the cabinet and cut the opening in the side of the 

furnace.

NOTE: Do not use the standard furnace

 indents for the 

opening. The opening for the air cleaner must be larger 

than the standard furnace opening. Install transition as 

required for air cleaner opening to match furnace opening 

as described below.

6.   Position the air cleaner on the return opening of the in-

door unit with the air cleaner cabinet gasket against the 

indoor unit. Check that the front of the air cleaner cabinet 

is facing the  front of the indoor unit.

7.   Align the rear of the air cleaner flush with the rear of the 

indoor unit.

8.   Align the sides of the cabinet with the sides of the unit. 

9.   The front of the cabinet will NOT align flush with the front 

of the unit.

10.  Securely fasten the unit using the self-tapping sheet 

metal screws provided. See Figure 19.

11.  Reinstall the FIELD CHARGER and lock into place by 

bending one locking tab on the cabinet. See Figure 16.

12.  Reinstall the PRE-FILTER and COLLECTION CELLS.

13.  Each cell must be oriented with the handles toward the 

front.

14.  The door can be installed in 

either direction

. See 

Door Operation Section C.

NOTE:  The door has a safety switch to ensure 

power is interrupted when the door is removed. 

This switch is open when the door is removed from 

the cabinet. When the door is properly installed, 

an actuator tab located in the cabinet will close the 

switch, allowing power to the electronics.

15. Remove stickers (two stickers both are 5.5" x 7.5") 

from the packet and attach to the furnace, air han-

dler, or ductwork in a location visible to the home-

owner.

16. Demonstrate Maintenance (Section H) and Door 

Operation (Section C) to the homeowner.

Use inner

mounting holes
for Side Installation

Install gasket material.

Cut to length required.

      

Содержание EFD145DLFR000 Series

Страница 1: ...t comply with NATIONAL STATE AND LOCAL CODES IMPORTANT This Document is customer property and is to remain with this unit Please return to service information pack upon completion of work Installation...

Страница 2: ...heck carefully for any shipping damage This must be reported to and claims made against the trans portation company immediately Check to be sure all major components are in the unit Any missing parts...

Страница 3: ...air cleaner to air handler furnace or ductwork please keep screws out of the circled areas The door attaches to the slots in the location Figure 7 Avoiding Screw Interference Supply Plenum Furnace or...

Страница 4: ...ions are preferred for greatest efficiency Four inches per linear foot approximately 20 angle should be allowed space permitting 9 Seal all joints in the return air system to prevent dust from enterin...

Страница 5: ...R FIELD CHARGER and both COLLECTION CELLS Set the components aside until the cabinet is installed and the indoor unit is in place 2 Install the self adhesive gasket material on the side of the air cle...

Страница 6: ...n the side of the air cleaner cabinet flange that will mate with the indoor unit This flange has a double set of holes See Figure 14 UPFLOW AIR HANDLER APPLICATIONS ONLY 9 Position the baffle onto the...

Страница 7: ...the indoor unit is in place 2 Install the self adhesive gasket material on the side of the air cleaner cabinet flange that will mate with the indoor unit This flange has a double set of holes See Fig...

Страница 8: ...E Wiring penetration must be sealed NOTE For non Trane American Standard Heating Air Conditioning systems order a 120 VAC to 24 VAC transformer KIT BAYTRANS12024 to provide 24 volt power only to the a...

Страница 9: ...ndler Figure 20A Wiring Diagram for 24 V Mode NOTE The Black wire must be con nected to chassis ground to ensure proper operation The represents an alpha character BAYTRANS12024 Transformer BLUE GREEN...

Страница 10: ...power going into the air handler 2 On the communicating systems air handler remove the blower access panel 3 Remove the communicating control box cover 4 Locate the red jumper wire which is attached f...

Страница 11: ...ISCONNECT POWER BEFORE SERVICING COULD RESULT IN DEATH OR SERIOUS INJURY ELECTRICAL CONNECTIONS TO A STANDARD 24 VOLT AIR HANDLER Field wiring O R B YI W1 YO Y2 BK G W2 W3 In Out O R B YI W1 YO G W2 W...

Страница 12: ...wire from the air cleaner wire harness to earth ground by attaching the wire to a grounded screw that is connected to the metal air handler chassis or control plate assembly 7 The Green and White wir...

Страница 13: ...quick connect terminal to the blue wire and the green wire 9 Attach the blue wire from the air cleaner wiring harness to the open tab on the piggyback terminal supplied in the BAYACCECOMM101 Attach pi...

Страница 14: ...with the air cleaner onto the IFC platform where the 35VA transformer was previously located Use the sheet metal screws supplied with the air cleaner to mount the 50VA transformer Reconnect the 115V...

Страница 15: ...and RH together Oil burner primary TT contacts must be isolated using field supplied relay RLY00925 or equivalent NOTE 3 The black wire Bk from ACCE unit must be connected to chassis ground to ensure...

Страница 16: ...e the wiring diagrams for information on how to attach the wires in a two whole house air cleaner system The figure on the top of page 16 shows the wiring hookup for two whole house air cleaners attac...

Страница 17: ...ems 17 Installer s Guide FIELD SUPPLIED 50 VA TRANSFORMER FIELD SUPPLIED 75 VA TRANSFORMER ELECTRICAL CONNECTIONS FOR DUAL WHOLE HOUSE AIR CLEANERS AND FURNACE IN CONVENTIONAL 24V MODE ELECTRICAL CONN...

Страница 18: ...IELD CHARGER in the SET UP mode NOTE There is a 10 12 minute delay after the indoor fan operates before the air cleaner starts to operate each time the power to the air cleaner is turned off on This c...

Страница 19: ...ER is to capture large particles before they enter the COLLECTION CELLS which allows the collection cells to work more efficiently 1 Turn the air conditioning system off at the Comfort Control thermos...

Страница 20: ...a vacuum hose vacuum in even strokes across the length of the PRE FILTER After vacuuming the entire PRE FILTER using even strokes going in one direction repeat the process using even strokes going in...

Страница 21: ...R CLEANER 1 Replace the PRE FILTER into the air cleaner Ensure that the AIRFLOW indicator arrow on the PREFILTER is pointing in the same direction as the AIRFLOW indicator arrow on the air cleaner cab...

Страница 22: ...ell Identification Alternate Cleaning option for homeowners with 200 or 200 1 COLLECTION CELLS ONLY Vacuuming the PRE FILTER and COLLECTION CELLS restores them to a high efficiency However some enviro...

Страница 23: ...and hold the RESET key until the COLLECTION CELL LED turns off 1 to 2 seconds If two air cleaners are connected on the same system reset all timers on both air cleaners at the same time to the same se...

Страница 24: ...de View AIRFLOW 27 DEPTH CABINET ADD DOOR DEPTH FOR TOTAL OUTLINE DRAWING FOR UPFLOW FURNACES Dimensions all dimensions in inches I OUTLINE DRAWINGS UPFLOW FURNACE MODEL NUMBERS ifD Air Cleaner A B mu...

Страница 25: ...D DOOR DEPTH FOR TOTAL Dimensions all dimensions in inches OUTLINE DRAWING FOR DOWNFLOW FURNACES DOWNFLOW FURNACE MODEL NUMBERS ifD Air Cleaner A B multiple piece cabinet B one piece cabinet EFD17DCLF...

Страница 26: ...EPTH CABINET ADD DOOR DEPTH FOR TOTAL OUTLINE DRAWING FOR AIR HANDLERS AIR HANDLER MODEL NUMBERS ifD Air Cleaner A B multiple piece cabinet B one piece cabinet EFD175CLAH000E 17 5 14 9 15 EFD215CLAH00...

Страница 27: ...FD175DLFR000 0 05 0 08 0 12 0 17 0 22 0 28 0 34 EFD210DLFR000 0 04 0 06 0 09 0 12 0 15 0 20 0 24 0 29 0 34 EFD245DLFR000 0 03 0 04 0 06 0 09 0 12 0 15 0 19 0 22 0 26 EFD17DDLFR000 0 07 0 11 0 18 0 25...

Страница 28: ...idential applications For more information please visit www trane com or www americanstandardair com The manufacturer has a policy of continuous data improvement and it reserves the right to change de...

Отзывы: