HD653-2c CP VARITHERM …BI 

page  2/ 3 

 

 

6 Options 

AM 

Failure alarm opening at < 5 °C 

3M 

Connection cable 10’/ 3 m long 

120V 

Nominal voltage 120V AC 

240-265V 

Nominal voltage 240-265V AC 

MB 

Stainless steel mounting bracket (bow-type) 

MW 

Stainless steel mounting brackets 

7 Installation 

Trouble-free installation, e.g. on a mounting plate or the 
INTERTEC mounting system (C-rails) in the instrument 
enclosures or protective cabinets, is possible. 
During installation, attention should be paid to the following: 

  Follow the installation and operating instructions supplied 

with the VARITHERM heater. 

  The fins must be positioned vertically 

  Please note minimum clearances to the enclosure, as per 

7.1 and 7.2 

  For temperature maintenance install the TAE thermostat 

on the heater, see 7.2 

  The label must be clearly legible 

7.1 

For North America with conduit 

Horizontal installation (recommended) 

 

Vertical Installation 

 

7.2 

IEC/ ATEX, with external TAE 

 

Horizontal Installation 

 

 
Vertical Installation 

 

 

Note:

 The convection is about 20% less at vertical installation. 

Due to earlier switching of the thermostat the effective heating 
power may be lower. 

 

The brackets in zinc coated steel and fixing bolts illustrated 
above are included with the heater. 
Furthermore, a short threaded rod for mounting the TAE 
thermostat on the heater is supplied with the TAE. 

min. 
1”/30mm

 

 min.

2”/50 mm

TS

min.  
1”/30 mm 

min. 
2”/50 mm 

TS

TAE

TAE