8
3.
Press the ‘Confirm’ button as many times as the number you want
to assign to this Outstation. For example; to programme the Out-
station to be number 11, press the ‘Confirm’ button 11 times. If
you want to programme the Outstation to be number 6, press the
‘Confirm’ button only 6 times. The ‘Standby’ light will then confirm
your programming by flashing the same number times.
4.
If the Outstation has been programmed correctly, you can simply
leave it and move to the next Outstation (whereupon after 30 sec-
onds the ‘Standby’ LED will stop flashing and the Outstation will
then remain programmed accordingly), or press and hold the
’Confirm’ button to re-boot the Outstation, or you can disconnect
the power cable (as in 1. above), wait for the Outstation to fully
power down, then reconnect. The Outstation will then be pro-
grammed to the new assigned number and the Main Unit will be
updated immediately.
5.
If when the Outstation confirms the programming the number is
incorrect and you need to change the number it is programmed to,
simply press the ‘Confirm’ button the required number of times
again and check the number of replayed flashes once more. When
correct, perform the confirmation by following the steps in 4.
above.
Dimming of Outstations
To dim the LEDs on Outstations, hold down the ‘Dimmer’ button on the
Main Unit and press the ‘Standby’ button on the channel assigned to the
Outstation in question. Each press of the ‘Standby’ button dims the LEDs
on the Outstation by 20%. When the illumination level is correct, simply
release all buttons on the Main Unit and the dimming programming is com-
plete. This process needs to be repeated for each additional Outstation
requiring dimming also.
IMPORTANT NOTE:
When enabled, the ‘Dimmer’ button is also a master reset of all cues!
If any cues have already been given (i.e. Standby, Confirmed and/or Go),
these will be cancelled instantly whenever the ‘Dimmer’ button is pressed.