Intersan Wallgate Thrii Скачать руководство пользователя страница 22

Thrii 

Installation

 

 

 

Page 

22

 of 

23

 

All information including dimensions, changes in design and material are subject 
to manufacturer’s change without formal notice and without obligation. Intersan 
assumes no responsibility for use of superseded or voided information. Verify all 
rough-in information before installation. It is the responsibility of the installer to 
conform with local and national codes.

 

Intersan Manufacturing Company 

1748 West Fillmore St., Phoenix, AZ 85007 

Phone: 800-999-3101 Fax: 602-254-1776 

intersanUS.com 

THRII-inst-Rev1 

by 

6.

 

For further adjustments repeat steps 1 to 5, or to exit the programming mode momentarily press the Menu 
Select button. A 20 second period of inactivity will automatically exit the programming mode and revert to 
displaying the time.  
 

Instructions can be downloaded from the Wallgate web site or contact Intersan to:  

 

 

Restore the unit to factory default settings. 

 

 

Instructions to change the cycle sequence of soap – water – hand dryer. 

 

 
 
 
 
 

8.

 

Care, Routine maintenance, Service & Repair  

The Thrii Hand wash dryer unit is well designed and manufactured from high quality materials. If you install, operate and 
maintain them according to the instructions given in this manual, the unit will give reliable and efficient service. If you 
need any further information or advice, please contact Wallgate Customer Services.  
 

8.1.

 

Routine maintenance  

 

The following routine regular maintenance in between service intervals will help to prevent premature parts failure:  
 

 

Flush the soap pump system with warm water to remove congealed soap within the pump, tube & soap nozzle.  

 

Clean the external surfaces of the soap nozzle to remove congealed soap.  

 

De-scale the water spray nozzle.  

 

Clean the lens on the infra-red hand sensor.  

 

Clean the waste outlets on the basin bowl and flush out / clean the waste sump.  

 

Clean & de-scale the wash bowl.  

 

Check the unit functions of soap, water and dryer dispensing are operating correctly. Any malfunction must be 
reported so that service repair work can be arranged to avoid further potential damage to the unit.  

 

Switch OFF the electrical power to the unit in the event of a serious fault or if the unit fails to operate. 

 

 
 

8.2.

 

Service and Repair  

 

Any service or repair work must be done by a qualified engineer. During the warranty period, the service or repair must 
only be done by an Intersan engineer or appointed service agent. Refer to the Wallgate Limited Terms and Conditions for 
warranty information.

 

Service warning indicator: 

The LCD display shown on fig 18 will show “Ser” when a recommended service is required or 

alternatively it is recommended that the unit is serviced every 56000 cycles or a minimum of once per annum.  

 

Service warning indicator reset: 

Press & hold buttons 2 & 4 together for 4 seconds. 

 
Any service or repair work must be done by a qualified engineer. During the warranty period, the service or repair must 
only be done by a Wallgate engineer or appointed service agent. Refer to the Wallgate terms and conditions for warranty 
information.  

 

Содержание Wallgate Thrii

Страница 1: ...with local and national codes Intersan Manufacturing Company 1748 West Fillmore St Phoenix AZ 85007 Phone 800 999 3101 Fax 602 254 1776 intersanUS com THRII inst Rev1 by Installation Instructions for...

Страница 2: ...by unqualified personnel No part of this publication and the information contained may be reproduced transmitted stored in a retrieval system used or disclosed wholly or partly without prior written p...

Страница 3: ...t is not necessarily in sequential order 2 6 Menu items Menu items submenu items and settings where available are given in bold 3 Glossary The glossary lists all words abbreviations and technical term...

Страница 4: ...92 lbs 5 73 lbs 48 06 lbs Dimensions Width Height Depth 17 3 4 31 1 4 12 1 4 17 3 4 34 1 4 12 1 4 9 7 8 behind the panel on all models Water Supply Minimum pressure Maximum rating Inlet connection si...

Страница 5: ...peration It is available in a solid surface or stainless steel grade 304 material The unit should only be installed in a frost free environment to avoid damage All models are identical with the except...

Страница 6: ...Manufacturing Company 1748 West Fillmore St Phoenix AZ 85007 Phone 800 999 3101 Fax 602 254 1776 intersanUS com THRII inst Rev1 by Item No Description Item No Description 1 Fascia 13 Hinge 2 Containe...

Страница 7: ...aste connector 1 Waste pipe 1 1 4 1 1 2 adapter pipe 1 Fascia lock key 1 Mains electrical plug and lead 6 1 2 ft length 1 User instruction label 1 Set of mounting brackets and fixings 1 Fascia 1 Engin...

Страница 8: ...accessible without requiring the fascia of the Thrii unit to be opened first Be sure to turn off the circuit breaker before working on or installing the Thrii unit Provide a cold water supply mounted...

Страница 9: ...ut obligation Intersan assumes no responsibility for use of superseded or voided information Verify all rough in information before installation It is the responsibility of the installer to conform wi...

Страница 10: ...out obligation Intersan assumes no responsibility for use of superseded or voided information Verify all rough in information before installation It is the responsibility of the installer to conform w...

Страница 11: ...superseded or voided information Verify all rough in information before installation It is the responsibility of the installer to conform with local and national codes Intersan Manufacturing Company...

Страница 12: ...etween the frame and the wall that may not be covered by the fascia 7 Install the waste connector to the frame as shown in figure below along with the pipe adapter which then is terminated to the deep...

Страница 13: ...cia so they are fully extended Position the fascia assembly so the two hinges are suspended next to the hinge side lock plates mounted on the support frame Have one person hold the fascia so it is sus...

Страница 14: ...the fascia and the wall along the hinged edge and adjust the hinges as appropriate to ensure an even fit using the adjustment screw on the hinges see figure below Do not over tighten as this may resul...

Страница 15: ...Intersan Manufacturing Company 1748 West Fillmore St Phoenix AZ 85007 Phone 800 999 3101 Fax 602 254 1776 intersanUS com THRII inst Rev1 by 6 5 Engine installation 1 Remove the engine cover retaining...

Страница 16: ...to the Thrii All electrical work must be carried out by a qualified electrician and should be installed in accordance with the current national regional and local regulations GFCI protection is likely...

Страница 17: ...7 Commissioning for use To commission the Wallgate Thrii 1 Ensure the engine cover is securely fitted and the electrical plug is fully pushed in 2 Fully open the water supply valve to the unit Check t...

Страница 18: ...container figure b and replace with the push fit cap pre connected to the soap tube figure c pushing fully into place ensuring no leaks 9 Press the soap prime switch located at the rear of the engine...

Страница 19: ...ensure that a copy of the instruction manual or leaflet the instruction label and the fascia lock key are passed to the customer 7 Program settings The Wallgate Thrii operational program is supplied f...

Страница 20: ...ntrols to set the required soap option are located on engine unit To change the settings the unit must be powered up There are 2 controls that need to be altered 1 At the window to the left of the mai...

Страница 21: ...on to select the desired setting this is confirmed by an illuminated LED and a five second fan cycle Note Lowering the fan speed will take longer to dry the hands 7 2 Advanced adjustment The unit is s...

Страница 22: ...ntenance in between service intervals will help to prevent premature parts failure Flush the soap pump system with warm water to remove congealed soap within the pump tube soap nozzle Clean the extern...

Страница 23: ...x AZ 85007 Phone 800 999 3101 Fax 602 254 1776 intersanUS com THRII inst Rev1 by Risk of electric shock serious injury or death Only qualified personnel should remove the cover of the engine unit when...

Отзывы: