 4.3. Replace Solenoid Lead

1. Check Sensor

Step 1

Follow steps 1,2,3 & 4
from the sensor
checking.

Step 3

Remove the screws from the center of the solenoid
valve lead at the solenoid valve. Unplug the solenoid
valve leads from the solenoid valve by gently pulling
straight up with pliers or prying up between the
solenoid valve and the solenoid lead

Step 4

Use caution not to
damage the gasket
between the valve
and the lead.

After the lead is
replaced, reinstall in
reverse order

If the problem is not solved by checking the solenoid valve, check the microprocessor

5. Check the microprocessor

Step 1

Follow steps 1,2,3 & 4
from the sensor
checking.

Step 2

Check that all the connections are secure.

Step 3

Disconnect the battery by depressing the battery
terminal lock and gently pulling the two halves
apart.

Make note that when reinstalling the sensor and
solenoid wires it is imperative that each valve and
sensor is paired up correctly.

Step 2

Unplug the  solenoid valve lead
from the microprocessor

 4.2. Solenoid Valve Replacement

Step 4

Turn the brass water body counter clockwise
and remove any remaining thread sealant.
After the valve is replaced reinstall in the
reverse order making sure the brass water
body is properly sealed to the manifold.

Step 3

Remove the four screws that travel
thru the coil into the brass water
body.

Step 1

Follow steps 1,2
& 3 from the
solenoid valve
checking (page 3
of the ISO
trouble shooting
guide)

Step 2

Loosen and remove tie nut
that fixes the valve, at the
bottom of the spray
nozzles.

Sanispray

®

 

Individual Sensor Operated

I

NTERSAN

®

 

REPAIR GUIDE

Содержание sanispray

Страница 1: ...SANISPRAY Individual Sensor Operated Repair Guide INTERSAN MANUFACTURING COMPANY 1748 W Fillmore St Phoenix Arizona 85007 Tel 602 254 3101 Fax 602 254 1776...

Страница 2: ...35 seconds the unit should be operational PROBLEM 1 UNIT CONTINUOUSLY BEEPS WHEN ACTIVATED Check and Replace Battery Pack Step 1 Open the water distribution head by using the supplied key and turning...

Страница 3: ...free 3 Supply lines are clean and pressure requirements are within the parameters 4 Thermostatic mixing valve has the correct supply connected to the hot and cold inlets 5 The check valves on the elbo...

Страница 4: ...ssor and separate lid from the base The problem should travel with the nonworking sensor and the adjacent sensor should activate the solenoid valve Replace the defective sensor with a new one If not c...

Страница 5: ...rt on the water part of the valve Insert 4 round head solenoid screws and tighten firmly 4 Check Solenoid Valve Step 3 Remove the solenoid valve leads from the solenoid valve by gently pulling straigh...

Страница 6: ...ssor Step 1 Follow steps 1 2 3 4 from the sensor checking Step 2 Check that all the connections are secure Step 3 Disconnect the battery by depressing the battery terminal lock and gently pulling the...

Страница 7: ...AGNOSTICS HAVE DETERMINED THE NECESSITY TO REPLACE THE MICROPROCESSOR PROBLEM 4 CONTINUOUS WATER FLOW Check Solenoid Valve In some cases the filters may not be enough to eliminate the debris from jamm...

Страница 8: ...f battery connector Date of installation Environment where unit is installed How the unit is used 3 To order replacement parts or to receive parts prices please contact your local rep 4 Use only Inter...

Отзывы: