Check if:
INTERSAN MANUFACTURING COMPANY
1748 W. Fillmore St. - Phoenix, Arizona 85007 - Tel 602.254.3101 - Fax 602.254.1776 - www.IntersanUS.com
NOTE: THIS INFORMATION IS SUBJECT TO CHANGE WITHOUT FORMAL NOTICE REV1.2
- 5 -
4.3. Replace Solenoid Lead
1. Check Sensor
Step 1
Follow steps 1,2,3 & 4
from the sensor
checking.
Step 3
Remove the screws from the center of the solenoid
valve lead at the solenoid valve. Unplug the solenoid
valve leads from the solenoid valve by gently pulling
straight up with pliers or prying up between the
solenoid valve and the solenoid lead
Step 4
Use caution not to
damage the gasket
between the valve
and the lead.
After the lead is
replaced, reinstall in
reverse order
If the problem is not solved by checking the solenoid valve, check the microprocessor
5. Check the microprocessor
Step 1
Follow steps 1,2,3 & 4
from the sensor
checking.
Step 2
Check that all the connections are secure.
Step 3
Disconnect the battery by depressing the battery
terminal lock and gently pulling the two halves
apart.
Make note that when reinstalling the sensor and
solenoid wires it is imperative that each valve and
sensor is paired up correctly.
Step 2
Unplug the solenoid valve lead
from the microprocessor
4.2. Solenoid Valve Replacement
Step 4
Turn the brass water body counter clockwise
and remove any remaining thread sealant.
After the valve is replaced reinstall in the
reverse order making sure the brass water
body is properly sealed to the manifold.
Step 3
Remove the four screws that travel
thru the coil into the brass water
body.
Step 1
Follow steps 1,2
& 3 from the
solenoid valve
checking (page 3
of the ISO
trouble shooting
guide)
Step 2
Loosen and remove tie nut
that fixes the valve, at the
bottom of the spray
nozzles.