1. Check Sensor

Step 6

Install the adjacent working sensor in the
non working position.

Step 5

Remove the defective sensor by depressing
the phone jack tab and gently pulling the
wire out of the slot

Step 4

Remove the four screws from the
microprocessor and separate lid from the
base

The problem should travel with the nonworking sensor and the adjacent sensor should activate the solenoid valve. Replace the defective sensor with a new
one

If not continue with 4. Check Solenoid Valve

To reinstall, reverse the above process

Step 3

Separate soap shelf halves by raising the
opposite ends and remove them

Step 2

Remove optional soap trays and soap bags
if supplied by manufacturer.

Step 1

Open the water-distribution head by using
the supplied key and turning the two locks
counterclockwise. Gently lift and remove the
cover

 3. Check Sensor

Sanispray

®

 

Individual Sensor Operated

I

NTERSAN

®

 

REPAIR GUIDE

Содержание sanispray

Страница 1: ...SANISPRAY Individual Sensor Operated Repair Guide INTERSAN MANUFACTURING COMPANY 1748 W Fillmore St Phoenix Arizona 85007 Tel 602 254 3101 Fax 602 254 1776...

Страница 2: ...35 seconds the unit should be operational PROBLEM 1 UNIT CONTINUOUSLY BEEPS WHEN ACTIVATED Check and Replace Battery Pack Step 1 Open the water distribution head by using the supplied key and turning...

Страница 3: ...free 3 Supply lines are clean and pressure requirements are within the parameters 4 Thermostatic mixing valve has the correct supply connected to the hot and cold inlets 5 The check valves on the elbo...

Страница 4: ...ssor and separate lid from the base The problem should travel with the nonworking sensor and the adjacent sensor should activate the solenoid valve Replace the defective sensor with a new one If not c...

Страница 5: ...rt on the water part of the valve Insert 4 round head solenoid screws and tighten firmly 4 Check Solenoid Valve Step 3 Remove the solenoid valve leads from the solenoid valve by gently pulling straigh...

Страница 6: ...ssor Step 1 Follow steps 1 2 3 4 from the sensor checking Step 2 Check that all the connections are secure Step 3 Disconnect the battery by depressing the battery terminal lock and gently pulling the...

Страница 7: ...AGNOSTICS HAVE DETERMINED THE NECESSITY TO REPLACE THE MICROPROCESSOR PROBLEM 4 CONTINUOUS WATER FLOW Check Solenoid Valve In some cases the filters may not be enough to eliminate the debris from jamm...

Страница 8: ...f battery connector Date of installation Environment where unit is installed How the unit is used 3 To order replacement parts or to receive parts prices please contact your local rep 4 Use only Inter...

Отзывы: