Section 7, Plumbing the System  

7-8 

 

The Hurricane

®

 Chinook Heating System 

It is recommended to contact the vehicle/engine manufacturer prior 
to proceeding with the engine plumbing installation. 

Prior  to  operating  the  engine  pre-heat  pump,  the  engine  coolant 
loop must be connected to the Hurricane

®

 Chinook and the coolant 

line  purged  of  air.  Do  not  run  the  engine  pre-heat  pump  without 
fluid or the pump will be damaged. 

 

 

Figure 7-5  Engine Heat / Pre-heat System Plumbing

 

 

7.7  Procedure for Filling/Purging the 

Hurricane

®

 Chinook Heating System 

 

Do  not  operate  the  Hurricane

®

  Chinook  Heating  System  until 

the  proper  water/anti-freeze  heat  transfer  fluid  solution  has 
been added to the Hurricane

®

 Chinook Heating System and all 

trapped  air  has  been  bled.  An  inadequate  mixture  of  heat 
transfer fluid could cause system circulation problems, potential 
heating system damage and/or personal injury. 

WARNING 

Содержание Hurricane Chinook Heating System

Страница 1: ...ricane Chinook Heating System has been designed to meet ABYC standards for installation in yachts This section covers critical information you need to know before beginning the installation including...

Страница 2: ...l information for a proper installation A properly installed Hurricane Chinook Heating System is essential for several reasons To ensure that you and or your customers receive satisfactory results and...

Страница 3: ...its integral fluid distribution pumps the Hurricane Chinook Heating System has the ability to circulate the heat transfer fluid to all space heating areas It can also provide a supply of potable hot w...

Страница 4: ...rning a wide variety of diesel based fuels CSA UL certified for diesel 1 and 2 Exhaust has minimal smoke and smell Fan assisted sealed combustion chamber is designed to use outside combustion air Low...

Страница 5: ...ors to keep in mind when planning and carrying out the installation are Mounting location restrictions for the Hurricane Chinook Heating System and exhaust outlet to reduce noise vibration heat loss e...

Страница 6: ...anty You will need the following equipment and tools to install the heating system not supplied This list does not include optional equipment and accessories Standard tools normally available in a wel...

Страница 7: ...he heating zones 1 6 Testing and Inspection After all components have been properly installed according to standard practices ABYC A 7 standards and the recommendations of this Installation and Operat...

Страница 8: ...Section 1 Overview 1 8 The Hurricane Chinook Heating System...

Страница 9: ...ne Chinook Heating System Hurricane Chinook Heating System weight when full 163 lbs Ventilation requirements Exhaust outlet location and maximum acceptable length including all 90 degree bends Refer t...

Страница 10: ...e outside case of the Hurricane Chinook Heating System The serial number identifies the model type through the first series of letters and numbers 2 3 Your Mounting Location Your mounting location sho...

Страница 11: ...ake connections The following are the minimum required clearances 12 top clearance 12 front clearance 0 clearance to all other Hurricane Chinook surfaces Allow 1 clearance on the left and right side f...

Страница 12: ...be unduly affected by vibration and jarring from rough roads Ensure that the exhaust tubing can be properly and safely routed to the outside The maximum exhaust run for the system is 12 including 90 d...

Страница 13: ...Mount the Zone Control Box containing the Zone Control Board vertically close to the Hurricane Chinook Allow sufficient room to access the internal fuses as well as to view the display LED s on the fr...

Страница 14: ...g Panel Mounting Procedure The Touchscreen Remote Control Panel is mounted inside the yacht in an easy to access location An opening for the remote panel must be cut in a wall location or a mounting p...

Страница 15: ...e drawn directly from the outside without coming in contact with air that can infiltrate the living areas See section 3 3 Never place any exhaust parts close to combustible material or through a combu...

Страница 16: ...rface of the thru hull and the surface to which it is mounted and the thru hull is centered within the mounting hole A dual thru hull must be oriented such that the fresh air inlet hole on the side of...

Страница 17: ...h an exhaust sealing compound to ensure the connection is tight and leak free All other exhaust connection must be made the same way Make sure the sealing compound does not restrict the exhaust flow T...

Страница 18: ...ur mounting location accommodates the use of the fresh air inlet saddle pipe Make sure the temperature rise of any combustible material surrounding the exhaust parts does not exceed 50 C 90 F when the...

Страница 19: ...ng to this fitting 6 Connect the fresh air inlet tubing to the saddle pipe on the thru hull Make sure the run of this tubing is as short as possible to provide good air flow Use a 32 gear clamp to att...

Страница 20: ...Section 3 Installing the Exhaust System 3 6 The Hurricane Chinook Heating System Figure 3 1 Installing the Exhaust System...

Страница 21: ...Heating System is not rated for use in an explosive environment Never share the fuel supply to the Hurricane Chinook Heating System with any other fuel burning device 4 2 Fuel System Installation The...

Страница 22: ...leaks after installation and also periodically as part of normal maintenance A primary UL and or CSA approved fuel oil filter not provided must be installed inline on the fuel supply hose between the...

Страница 23: ...tting on the main fuel tank 3 Connect the fuel return line to the fuel return fitting on the main fuel tank NOTICE The fuel return line from the heater may be connected to a common return line Make su...

Страница 24: ...Section 4 Installing the Fuel System 4 4 The Oasis Chinook Heating System...

Страница 25: ...ommended this switch be installed with this fan For best results the fans should be mounted as close to the floor as possible Some have a built in aquastat optional temperature sensing switch which tu...

Страница 26: ...ll not run the fans unless the coolant inside the Hurricane Chinook tank is above 120F However during the initial startup the coolant in the lines will be lower than 120F until it has had a chance to...

Страница 27: ...t heat for the installed heater unit Fan Guards to protect the fan blades from damage recommended for fans installed in storage areas or other accessible areas where something could contact the fan bl...

Страница 28: ...ose the mounting locations of your fans Locate the fans to evenly heat the specific zone Provision must be made to protect potable water lines from freezing Install fan at floor level or very near flo...

Страница 29: ...wire these up to the Zone Control Board in Section 6 Wiring The Electrical System 4 The Zone Control Board can control up to 5 zones The cabin fan 1 lead orange can supply up to a maximum of 10 Amps...

Страница 30: ...Section 5 Installing Fan Heaters 5 6 The Hurricane Chinook Heating System Figure 5 2 Mounting a Low Profile Cabin Fan Figure 5 3 Installing a Relay for Additional Fan Amperage...

Страница 31: ...eater Hurricane Chinook Remote Operating Panel Hurricane Chinook Zone Control Board Thermostats Cabin Fans To review the wiring for the Hurricane Chinook Heating System refer to the wiring diagram sho...

Страница 32: ...d Green White Black White Black Black 110 VAC Battery _ Master Disconnect 25A Fuse 20A Fuse Battery _ Cabin Fans Thermostats Thermostat 1 White Thermostat 2 Yellow Thermostat 3 Pink Thermostat 4 Tan T...

Страница 33: ...ower system is required for safe trouble free operation 6 3 Hurricane Chinook 120 VAC The Hurricane Chinook Heating System is equipped with two 1500 watt 120 VAC 60 Hz immersion elements The connectio...

Страница 34: ...ntrol Board connects to the thermostats and cabin fans through a 14 pin plug with butt connect leads Cabin Fan leads refer to Fig 6 1 for system wiring information The positive red lead from each cabi...

Страница 35: ...which is the only space heating pump in this system This will result in cold air blowing from the fans when only zones 3 4 or 5 are calling for heat See Section 8 Fig 8 6 for zone board jumper locatio...

Страница 36: ...Section 6 Wiring the Electrical System 6 6 The Hurricane Chinook Heating System...

Страница 37: ...a leak in the heat exchanger which could be caused if the fresh water in the system is allowed to freeze For an efficient Hurricane Chinook Heating System operation you must Minimize heat loss from th...

Страница 38: ...EX Refer to Figure 7 3 for connecting PEX tubing to the 3 4 hose barb connections All fittings except the Heat Loop return fitting on the Hurricane Chinook require two wrenches when tightening One wre...

Страница 39: ...Section 7 Plumbing the System International Thermal Research 7 3 Figure 7 1 Hurricane Chinook Overview Figure 7 2 Plumbing Hurricane Chinook for 5 Zones...

Страница 40: ...e preceding fan The temperature difference will be larger if the fan has a higher BTU output The Hurricane Chinook should be filled and flushed prior to operation to remove any foreign debris Use heav...

Страница 41: ...rs the bottom of the heating core and exits from the top This helps keep air from being trapped in the cabin fan core Ensure proper direction of flow See Figure 7 1 for the location of the fittings En...

Страница 42: ...orresponding PEX fittings on top of the heater These connections are crimped using appropriate pex clamps The maximum potable water supply pressure to the heater is 150 PSI 10 bar The Hot water Outlet...

Страница 43: ...hose is used 1 2 to 1 2 or 1 2 to 3 4 barb fittings can be used to make the connection to the engine See Sec 8 Fig 8 3 for location of the mixing valve If the optional engine pre heat function is req...

Страница 44: ...un the engine pre heat pump without fluid or the pump will be damaged Figure 7 5 Engine Heat Pre heat System Plumbing 7 7 Procedure for Filling Purging the Hurricane Chinook Heating System 1 Do not op...

Страница 45: ...the end of the suction hose from the pump into a reservoir of 50 50 heat transfer fluid propylene glycol based coolant and water Open the ball valve attached to the barbed fitting and turn ON the pump...

Страница 46: ...OFF the Bypass Switch on the Zone Control Board This Bypass Switch should remain off during normal operation It is only used to fill and purge the system The shut off valve on the filler hose must be...

Страница 47: ...ransfer fluid to provide a source of heat for all hydronic space heating needs Through the use of its integral distribution pumps the Hurricane Chinook Heating System has the ability to circulate the...

Страница 48: ...steel burner and a 7 US gallon welded and insulated stainless steel coolant tank The coolant tank is designed to minimize heat loss and optimize heat recovery Domestic water flow switch for quick res...

Страница 49: ...tion and diagnostic information 8 2 Operating Instructions for the Hurricane Chinook Heating System The Hurricane Chinook Heating System must be installed and connections made in accordance with the r...

Страница 50: ...pushed ON power LED will turn ON to turn the DC electrical power to the main control board ON and is required to be left ON whenever heat is required The Zone Control board Figure 8 4 will be powered...

Страница 51: ...burner will continue to operate until the coolant in the Hurricane Chinook reaches the set cycling temperature at which point the diesel burner will shut OFF If the system coolant should cool down bel...

Страница 52: ...Heat Source Available Any thermostat connected to the Zone Control Board calling for heat will cause the cabin fan controlled by that thermostat and coolant circulation loop pump to activate The cabin...

Страница 53: ...etween 75F 24 C min and 145F 63 C max The mixing valve will compensate for temperature variations of incoming supply water and maintain the temperature to which it is set However in some cases the tem...

Страница 54: ...8 Activating Engine Heat Pre heat Burner and or AC Heat On Pre heating the engine optional In order to use the engine pre heat feature and optional externally mounted pump must be installed see fig 7...

Страница 55: ...and or the AC elements will remain off if enough heat is provided by the engine If the heat transferred from the engine is not sufficient to meet the space heating and potable hot water demand the bu...

Страница 56: ...the up arrow button is pushed a second time 3 0KW will be displayed indicating the current draw associated with two 120 VAC elements The electrical symbol will illuminate when AC power is available a...

Страница 57: ...n turns ON when the power to the control board is ON Bypass Button The bypass button is for authorized service personnel only Reset Button The reset button when pressed resets the control board Power...

Страница 58: ...1 2 3 4 and 5 Thermostats and Potable Water It also contains nine matched pairings of red green LED s for Zone 1 2 3 4 and 5 Fans Summer Loop Heat Loop 1 Heat Loop 2 and Engine Pre heat Pump For the Z...

Страница 59: ...the Summer Pump and circulate hot coolant from the heater through the section of the heat exchanger that transfers heat to the engine coolant At the same time the engine pre heat pump will turn ON an...

Страница 60: ...e red LED turns ON if a fuse has been blown When the series jumper on the Zone Control board see sec 8 11 is in the correct default position both Heat Loop 1 and Heat Loop 2 green LED s will turn ON w...

Страница 61: ...ies jumper Figure 8 6 Zone Control Board Jumper s location 8 13 Maintenance Customer Monthly Maintenance Check the following and correct as required Coolant hoses and fittings for leaks and integrity...

Страница 62: ...heir remaining service life ending without any apparent visual signs or operating symptoms The major components such as the air compressor fuel pump fuel nozzle and combustion air fan should be examin...

Страница 63: ...damage the internal parts including the heat exchanger For winterization it is recommended that the potable water system be flushed with winterizing antifreeze that is safe for use in the potable wat...

Страница 64: ...circuit breakers tripped Burner Starts but Flame Faults Fuel nozzle plugged or dirty Fuel supply present and adequate Air intake or exhaust not blocked or obstructed Air in fuel line white smoke from...

Страница 65: ...ecords It will be a valuable reference if you need warranty repairs in the future Limited Warranty The following warranties are in lieu of all other warranties and conditions ITR makes no other warran...

Страница 66: ...Not Covered Under Warranty Warranty will be voided or not extended in the following circumstances Owner fails to notify ITR or the authorized ITR dealer from which the Product was originally purchased...

Страница 67: ...blem have the following information ready at hand model number and serial number of the Product a detailed description of the problem your Installation Manual and Owner s Manual Depending on your loca...

Страница 68: ...Telephone Email Service Service information given over the telephone by fax or by email is given only in good faith as an accommodation to the customer Such information should not be relied upon with...