www.irf.com
Page 20 of 34
IRAUDAMP10 REV
1.1
Selectable Dead-time
The dead-time of the IRS2052 is set based on the voltage applied to the DT pin. Fig 18 lists the
suggested component value for each programmable dead-time between 45 and 105 ns.
All the IRAUDAMP10 models use DT1 (45ns) dead-time.
Dead-time Mode
R1
R2
DT/SD Voltage
DT1 <10k Open Vcc
DT2
5.6k
4.7k
0.46 x Vcc
DT3
8.2k
3.3k
0.29 x Vcc
DT4 Open <10k COM
Recommended Resistor Values for Dead Time Selection
Vcc
0.57xVcc
0.36xVcc
0.23xVcc
105nS
85nS
65nS
45nS
V
DT
Dead-time
Vcc
COM
DT
>0.5mA
R1
R2
IRS2052M
Fig 18 Dead-time Settings vs. V
DT
Voltage