www.irf.com
Page 15 of 34
IRAUDAMP10 REV
1.1
Short Circuit Protection Response
Figs 14-15 show over current protection reaction time of the IRAUDAMP10 in a short circuit event.
As soon as the IRS2052M detects an over current condition, it shuts down PWM.
After one
second, the IRS2052M tries to resume the PWM. If the short circuit persists, the IRS2052M
repeats try and fail sequences until the short circuit is removed.
Short Circuit in Positive and Negative Load Current
Fig 14 Positive and Negative OCP Waveforms
.
OCP Waveforms Showing CSD Trip and Hiccup
Fig 15 OCP Response with Continuous Short Circuit
Load current
CSD pin
VS pin
Load current
CSD pin
VS pin
Load current
CSD pin
Load current
VS pin
CSD pin
VS pin
Load current
VS pin
Load current
VS pin
Positive OCP
Negative OCP