1.        Safety 

Read the following safety information carefully before attempting 

to operate or service the meter. 

Use  the  meter  only  as  specified  in  this  manual;  otherwise,  the 

protection provided by the meter may be impaired. 

 

Environment conditions: 

RH≤90

%(

Non-Condensation

 

Operating Temperature: -20

℃~

60

 

Storage Temperature: -20

℃~

60

   

 

Maintenance   

Repairs  or  servicing  not  covered  in  this  manual  should  only  be 

performed by qualified personnel. 

Wipe  the  unit  with  a  dry  soft  cloth.  Do  not  use  abrasives  or 

solvents on this instrument. 

 

Safety Symbol 

  Comply with EMC 

Содержание ILT10C

Страница 1: ...ILT10C User s Manual Professional Light Meter Please read this user s manual thoroughly before using this unit and keep it properly for your future reference ...

Страница 2: ...Contents 1 Safety 1 2 Application 2 3 Features 3 4 Specifications 4 5 Meter Description 5 6 LCD Display Description 6 7 Operation Instruction 7 8 Notes 9 9 Accessories 9 ...

Страница 3: ...rotection provided by the meter may be impaired Environment conditions RH 90 Non Condensation Operating Temperature 20 60 Storage Temperature 20 60 Maintenance Repairs or servicing not covered in this manual should only be performed by qualified personnel Wipe the unit with a dry soft cloth Do not use abrasives or solvents on this instrument Safety Symbol Comply with EMC ...

Страница 4: ...ation This Light Meter is designed to meet the measurement requirements of safety Engineers Health Industrial safety offices and light quality control in various environments like factory school construction etc ...

Страница 5: ...r spectral relative efficiency Automatically revise parameters for un standard illumination Short rise and fall times Selectable measuring units Lux or Fc Meter automatically shuts down after approx 15 minutes of inactivity MAX MIN record Large LCD display Peak hold 4 level selectable measurement ranges Automatic measurement Low battery indication ...

Страница 6: ...ral accuracy CIE Vλ function f1 6 f2 2 Accuracy 3 rdg 0 5 f s 10 000Lux 4 rdg 10dgts 10 000Lux Sampling rate 2 times per second Photo detector Silicon photo diode with spectral response filter Power supply One 9V battery 006P NEDA1604 or IEC6F22 Photo detector Lead Length approx 2 5m Battery life at least 30 hours Operating conditions 20 60 10 RH 90 RH Storage conditions 20 60 10 RH 75 RH Dimensio...

Страница 7: ...5 5 Meter Description Photo Sensor LCD display Lux Fc selection key MAX MIN key Range level selection key Backlight HOLD key Power ON OFF key Battery Cover ...

Страница 8: ...scription Low range indication icon MAX icon MIN icon Over range indication icon Range indication Analog bar graph indication Lux Fc record Low battery icon Auto range icon Hold icon LUX icon Fc icon Auto power off icon ...

Страница 9: ...the backlit will be on off it will automatically turn off after approx 30 seconds of inactivity 3 Data Hold Press key one time HOLD icon will appear on the LCD which indicates the data is freezed To release the held reading press the key again 4 Fc Lux Selection Press the key to select Fc units or Lux units 5 MAX MIN In the measurement mode press key one time MAX icon will appear on the LCD to vie...

Страница 10: ...reading Press this key once more to exit the MAX MIN mode Press key for 3 seconds above re start to calculate the maximum minimum 6 Range selection Press key to select the range level there are four selectable levels 0 400Lux 400 4kLux 4k 40kLux 40k 400kLux AUTO 0 400kLux ...

Страница 11: ...socket before measurement 3 When manual range is needed press LEVEL key to select the desired range if UNDER or OVER icon appears on the LCD which indicates incorrect range and need to select again 4 Remove the battery when the meter is to be stored for long periods of time to avoid battery leakage 9 Accessories User s manual Photo detector 9V battery ...

Страница 12: ......