Programming Options Chart

If the pre-programmed default values must be changed or additional functions are desired, the following
options may be programmed.

 

Enter programming mode

Press: 99 

#

 (master code)

*

The master default code is 1234 and the 212iLM must be in programming to make any changes.

 

Changing the master code

Press: 1 # (new code)

*

(repeat code)

*

 

Change the main relay activation time:

Press: (relay time) # 1 # (mastercode)

*

(repeat code)

*

All main relay times are entered in a 2-digit format.  For example: 08 for eight seconds.

Example:  Master code with an 8 second relay time: Press: (08) 

#

 1 

#

 1234 

*

 1234 

*

 

Add

 

or change

 

user codes

Press: (user location) # (new code)

*

(repeat code)

*

Codes entered in this fashion will hold the same relay time that the master code is programmed with.  If the
relay time is changed after all other programming is done, the codes will not follow the master code for time.
You will have to either change time manually or reset defaults and reprogram.  User locations are explained in
Section 5.

 

Add a user to latch the main relay:

Press: (00) # (user location) # (new code)

*

(repeatcode)

*

 

Add a user with a different output time on the main relay:  Press: (relay time) # (user location) # (new

code)

*

(repeat code)

*

Example:  User code with a 8 second relay time Press: (08) 

#

 2 

#

 1234 

*

 1234 

*

 

Turn audible keypress feedback ON

Press: 30 #  0 # 1 #  

*

  

*

 

Turn audible keypress feedback OFF

Press

30

 

#

  

0

 

#

 

0

 

#  

*

  

*

 

Turn visual keypress feedback ON

Press

30

 

#

  

1

 

#

 

1

 

#  

*

  

*

 

Turn visual keypress feedback OFF

Press

30

 

#

  

1

 

#

 

0

 

#  

*

  

*

 

To enable keypad illumination:

Press: 30 # 3 # 1 #  

*

  

*

 

To disable keypad illumination:

Press: 30 # 3 # 0 #  

*

  

*

 

To

 

enable keypad dimming:

Press: 30 # 4 # 1 # 

*

 

*

 

To disable keypad dimming:

Press: 30 # 4 # 0 # 

*

 

*

 

To enable the doorbell function:

Press: 30 # 5 # 1 #  

*

  

*

 

To disable the doorbell function:

Press: 30 # 5 # 0 # 

*

  

*

 

To set the length of time for the bell for continuous operation:

Press

32

 

# 0

 

#

 

0

 

#   

*

  

*

 

To set the length of time for the bell for timed operation

Press: 32 # 0 # (time) #   

*

  

*

 

Turn Auto-Entry ON (eliminates using the star key after a code)

Press

30

 

#

  

2

 

#

 

1

 

#  

*

  

*

 

Turn Auto-Entry OFF

Press

30

 

#

  

2

 

#

 

0

 

#  

*

  

*

 

Erase entire keypad memory and reset defaults:

Press

46

 

#

  

00000

 

#

 

00000

 

#  

*

  

*

For a detailed explanation of each option please refer to prior pages 7-11.

Содержание 212iLM Mullion

Страница 1: ...ontinuous v Designed for Heavy Traffic Application greater than 1 million cycles v Surface Mount v Indoor outdoor Applications v Fully encapsulated Installation q Section 1 Unpacking and checking the...

Страница 2: ...ng for the wire splices a ruler or measuring tape silicone to seal any holes and possibly some electrical tape to hold the wires together or the template in place q Section 2 Mounting the 212iLM Mulli...

Страница 3: ...lue common wire from the 212iLM Mullion harness to the Red wire on the 212iLM Mullion harness and to positive voltage coming from the power supply Step 2 Connect the White Yellow wire normally closed...

Страница 4: ...ss of the 212iLM Mullion Step 1 Splice together the Blue common Relay wire from the 212iLM Mullion harness to the Red wire on the 212iLM Mullion harness and to positive voltage coming from the power s...

Страница 5: ...common wire from the 212iLM harness to the Positive voltage on the lock power supply Step 5 Connect the Negative voltage coming from the lock power supply to the Negative connection on the Electric S...

Страница 6: ...the external relay Step 1 Connect the White with Black trace wire on the 212iLM Mullion harness to the common connection on the REX device Step 2 Splice a wire to the Black negative wire on the 212iLM...

Страница 7: ...ing mode has been exited The red LED should now be on Perform the Self Test by pressing 7890 123456 The LED s will cycle from Green to Yellow to Red and then the sounder will beep three times Press 12...

Страница 8: ...n comes with the factory programmed Master code of 1234 This may be changed to any code that has 1 to 6 digits in length The 212iLM Mullion also comes set from the factory with a 5 second relay activa...

Страница 9: ...is entered to close the relay Enter Programming Mode 99 Master code Next enter the relay time of 00 followed by the key Next enter the user location 2 3 4 etc followed by the key Now enter the new cod...

Страница 10: ...ess Command number 30 followed by the key Next press 1 for the visual feed back option followed by the key Next press 0 to Disable or 1 to Enable the visual option followed by the key Next press the k...

Страница 11: ...ng Mode 99 Master code Next press Command number 32 followed by the key Next press 0 for the doorbell option followed by the key Next press 0 for continuous Or enter a time of 1 trough 99 for timed ou...

Страница 12: ...lts When this command has been done successfully the 212iLM Master code will return to the default of 1234 and the main relay will activate for 05 seconds The 212iLM Mullion has to be in programming m...

Страница 13: ...nd reprogram User locations are explained in Section 5 Add a user to latch the main relay Press 00 user location new code repeatcode Add a user with a different output time on the main relay Press rel...

Страница 14: ...d of 35 Volts you must reduce the voltage to under 29 Volts Situation 3 The Master code is not allowing access to the programming mode Reason There are a few reasons that this situation could occur Th...

Страница 15: ...sent to IEI s facility freight and insurance charges prepaid after obtaining IEI s Return Merchandise Authorization IEI WILL not be liable to the purchaser or any one else for incidental or consequen...

Страница 16: ...6051344 Rev 1 0 Page 16 of 17 NOTES IEI suggests that you make a record of your installation for future reference...

Страница 17: ...6 1 4 Diameter of the mounting holes is 11 64 Diameter of the wiring holes is 7 8 This product is designed as a surface mountable product The access hole for the wires is determined by the amount of...

Отзывы: