44
7.
Error handling
In case of an error, there are three possible states:
a) The LED STATUS 1 is permanently off.
b) The LED ERROR is permanently on.
c) The LED STATUS 1 is permanently off and the LED ERROR is permanently on.
The first measure could be a re-start of the unit by either switching the AC power off
and ( after a few seconds ) on again, or by triggering a re-start through the
web-interface, or the front panel keyboard ( refer to section 6.1 Via front panel
keyboard). If the error persists, the configuration should be checked for
unreasonable parameters, like the ASI-transport stream bit rate being too low or
much too high, or an unsupported MPEG2/4-encoding bit rate.