SELECTING THE FAN SPEED

AUTO

FAN

OPER

ºF

ºC

HOUR
ON/OFF

   

:

Low / Med / High

indicator

AUTO

A09649

The fan speed can be selected by pressing the “FAN”

button.

Fan Speeds: Low

Medium

High

NOTE: 

When the unit is on, the fan will run continuously in

cooling or heating.  When in heating, there might be
situations  where the fan will slow down or shut off to

prevent cold blow.

TURBO MODE: 

(Only available on sizes 9K to 24K)

The desired setpoint, either in heating or cooling, can be

achieved faster if TURBO mode is used.  After selecting the

“HEAT” or “COOL” mode button, push the “TURBO” button.

This will force the unit to run at super high speed.  When

the setpoint is satisfied, push the “TURBO” button again.

The unit will run at the selected fan speed.
When TURBO mode is running, the following is displayed

on the remote control:

OPER

º

F

º

C

HOUR
ON/OFF

   

:

TURBO

ICON

A09636

Displaying Setpoint or Room Temperatures on Front

Panel:

 (Only available on sizes 9K to 24K)

The setpoint temperature or room temperature can be

displayed on the front panel.  Only setpoint temperature is

displayed on the remote.

º

F

º

C

HOUR
ON/OFF

   

:

Room
Temperature
Symbol

A09638

When the “TEMP” button is pushed once, the temperature

indicator (without thermometer) is displayed.  This indicates

that the setpoint temperature is displayed on the front panel.

When the “TEMP” button is pushed a second time, a

thermometer is displayed inside the temperature indicator.

This indicates that the room temperature is displayed on the

front panel.

NOTE: 

If any other button is pushed on remote control, the

temperature will return to the setpoint temperature. Outdoor
air temperature is not available.

Using Dry Coil Function (X

Fan):

When operating in humid areas, hi

wall units have a DRY

COIL function that will allow the indoor fan to run for a

pre

determined amount of time (10 minutes) after the unit

is turned off 

(cooling or dry modes)

 to ensure that

additional moisture is removed from coil.  Push the “X

FAN”

button to enable this feature.   This will be displayed on

remote control.

OPER

º

F

º

C

HOUR
ON/OFF

   

:

Remote
Dry Coil
Display

Remote
Dry Coil
Display

Size 9K to 24K

Size 30K & 36K

A09637

To deactivate this feature, push the “X

FAN” button again.

Selecting the Horizontal Direction Louver

Position

When the unit is turned on, the louvers default to the cooling

or heating position.
If the louver position is not providing adequate comfort due

to room layout or where people are gathered, two options

are available to correct the situation:

Size 9K to 24K Systems
Setting the louvers in a stationary position 

(other than default for heating and cooling):

The stationary position can be one of five (5) default

positions.
To change the louver position, press the 

 “SWING“

button once.  The 

 icon is displayed on the remote.

OPER

ºF

ºC

HOUR
ON/OFF

   

:

Swing Icon

A09640

When the 

 is displayed, the louver will swing

continuously between positions 1 and 5 as shown below.

Содержание DLC4A

Страница 1: ...ormation Manual carefully before installing and using this appliance and keep this manual for future reference For your convenience please record the model and serial numbers of your new equipment in the spaces provided This information along with the installation data and dealer contact information will be helpful should your system require maintenance or service UNIT INFORMATION Model __________...

Страница 2: ...s product WARNING GENERAL The high wall fan coil unit provides quiet maximum comfort In addition to cooling and or heating the high wall fan coil unit matched with an outdoor condensing unit will filter and dehumidify the air in the room to provide maximum comfort IMPORTANT The high wall fan coil unit should be installed by authorized personnel only using approved tubing and accessories If technic...

Страница 3: ...r Outdoor Unit A08294a 1 Front Panel Frame 2 Display Panel 3 Front Panel 4 Air Filter 5 Horizontal Airflow Louver 6 Manual Adjustable Vertical Airflow Louver 7 Remote Control 8 Room Temperature Sensor 9 Inter Connecting Tubing 10 Control and Power Wiring to Indoor Unit 11 Service Valves 1 2 3 4 5 6 7 8 9 10 11 ...

Страница 4: ... Button to Turn ON or OFF Display on Front Panel 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Remote Control Size 30 36 1 Remote Control Display 2 ON OFF Button 3 MODE Button 4 Setpoint Timer Up and Down Buttons 5 Fan Speed 6 Horizontal Louver Swing Button 7 Left Right Louver Swing Button Not available with these models 8 HEALTH SAVE Button Not available with these models 9 Dry Coil Button 10 Temperature Butt...

Страница 5: ...TURE DISPLAY Temperature setting from 61_F 16_C to 86_F 30_C will be displayed If FAN mode is selected there will be no temperature displayed 7 CLOCK DISPLAY Indicates the current time 0 to 24 hours 8 CLOCK INDICATOR Displayed with time and is not displayed when setting ON OFF timer 9 TIMER ON TIMER OFF DISPLAY ON is displayed if TIMER ON is set OFF is displayed if TIMER OFF is set ON OFF displaye...

Страница 6: ...nt operation mode AUTO COOL DRY FAN ONLY or HEAT 5 SLEEP DISPLAY Indicates unit is running in SLEEP mode 6 TEMPERATURE DISPLAY Temperature setting from 61_F 16_C to 86_F 30_C will be displayed If FAN mode is selected there will be no temperature displayed 7 Left Right Louver Swing Not available on these models 8 Health Save Not available on these models 9 SETTING ON OFF TIMES 0 5 to 24 hours 10 TU...

Страница 7: ...only from remote control to fan coil The remote control can perform the following basic functions S Turn the system ON and OFF S Select operating mode S Adjust room air temperature set point and fan speed S Adjust airflow direction Refer to the Remote Control Function section for detailed description of all the capabilities of the remote control Battery Installation Two AAA 1 5 v alkaline batterie...

Страница 8: ...t will confirm receipt of a command by sounding an audible beep 1 Turn the unit on by pushing the ON OFF button 2 Select the desired mode by pushing the mode button Size 9K to 24K Size 30K to 36K Only for heating and cooling units Only for heating and cooling units A08301 3 Select the temperature set point by pointing the control toward the unit and pressing the or buttons until the desired temper...

Страница 9: ...nt and time OPER will disappear NOTE If the On Off button is pressed too soon after a stop the compressor will not start for 3 minutes due to the inherent protection against frequent compressor cycling When turning the unit ON and OFF the Timer and Sleep functions will be cancelled SELECTING THE OPERATING MODE Use the MODE button to select one of the available modes Size 9K to 24K A09641 A09628b S...

Страница 10: ...n the TEMP button is pushed a second time a thermometer is displayed inside the temperature indicator This indicates that the room temperature is displayed on the front panel NOTE If any other button is pushed on remote control the temperature will return to the setpoint temperature Outdoor air temperature is not available Using Dry Coil Function X Fan When operating in humid areas hi wall units h...

Страница 11: ...e user to select the swing or a stationary position To change the louver position press the SWING button once The icon will be displayed on the remote Swing Icon Size 30K 36K The louver will swing continuously If the SWING button is pushed again the louver will stop in its present position If the user prefers to select swing with 5 preset stationary positions follow the instructions below S Turn O...

Страница 12: ... only OPER ºF ºC HOUR OFF Only OFF is displayed A09642 This function will allow the unit to stop automatically at the set time The timer can be set while the unit is on or while it is off To set the TIMER OFF function perform the following 1 Push the TIMER OFF button once 2 The clock indicator and time will not be displayed OFF will be flashing 3 Push the or button within 5 seconds until the desir...

Страница 13: ... the indoor unit front panel ON or OFF The remote control will display the Light Icon as shown below Light Icon Size 30K 36K Size 9K to 24K Light Icon Time Delay If the On Off button is pressed too soon after a stop the compressor will not start for 3 minutes due to the inherent protection against frequent compressor cycling The unit will only emit an audible beep when the signals are received cor...

Страница 14: ...ilure to follow this caution may result in equipment damage When cleaning the front panel do not use water hotter than 105_F 40 56_C and do not pour water onto the fan coil Do not use abrasive or petroleum based cleaners as they may damage the front panel CAUTION Indoor Unit Front Panel To clean the front panel on the indoor unit wipe the outside with a soft dry cloth If necessary a mild liquid de...

Страница 15: ...einsert plug Restart unit Water leaks into room from Indoor unit Condensing water has overflowed Check indoor condensing drain or call your representative Unit System Does Not Work To protect the unit upon an immediate restart after a stop the system controller will delay the unit for 3 minutes before allowing the unit to start back up The circuit breaker has tripped or a fuse has blown Power fail...

Отзывы: