7
4)
SUMMER SEASON
Make sure the fuel oil valve is closed when the boiler
is not used for long period of time.
5)
START-UP AT THE BEGINNING OF
THE HEATING SEASON
1. Clean the chimney, the connecting flue pipes and
the boiler. Follow steps in section 3, paragraph 6
to proceed;
2. Replace the oil filter;
3. Have the burner electrodes cleaned along with the
burner retention head and change the nozzle;
4. Check the operation of the high temperature
control limit;
5. Check the operation of the circulating pump.
PART 3
MAINTENANCE
1)
MAINTENANCE
The area around the boiler must be kept free of
combustibles, excessive dust and humidity, and highly
flammable products. Fresh air openings to the boiler
and the boiler room must be kept clear. Repair any
water and oil leaks without delay.
2)
NOZZLE
A dirty or clogged nozzle can prevent ignition or cause
odours. It must be replaced.
3)
FUEL TANK
Regularly check the level in the fuel tank. Should the
tank run dry, the fuel lines will have to be bled before
restarting the burner.
4)
OIL FILTER
Replace the oil filter at the beginning of the heating
season.
5)
BURNER AND CIRCULATING PUMP
MOTORS
Motors should be lubricated at least once a year
(except life time lubricated motors), with 2 to 3 drops
of SAE 20 non-detergent oil, put in the appropriate
access.
6)
CLEANING THE BOILER
1. Put the main switch “OFF” before any cleaning
works;
2. Remove and clean the connecting flue pipe and,
sweep and check the chimney;
3. Remove the smoke box and the fire tube baffles
and, with the help of a 2 inches diameter steel
brush, clean the fire tubes;
4. Remove the burner and clean the combustion
chamber. Take care to not damage the ceramic
bottom pad;
5. Examine the cleaned surfaces for corrosion and
correct the cause, if need;
6. Reinstall all components in their original position
and re-adjust the unit.
7)
BOILER PURGE
It is recommended to purge the boiler about 1 minute
at least once a year, to evacuate mud and sediments
accumulated at the bottom of the boiler.
Proceed as follows :
1. Let the boiler cool down;
2. Hook-up a garden hose from the drain valve to an
open bucket;
3. Open the drain valve until the water is clear.
8)
SPARE PARTS
It is always recommend to replace a defective part by
a genuine part, available at your supplier.