Page 11 of
85
2.2 Maintenance
Safety
!!! WARNING !!!
COMPRESSED GAS IS A HIGHLY
DANGEROUS SUBSTANCE.
BEFORE DISMANTING ANY PART OF
THE COMPRESSOR, ENSURE THAT THE
UNIT IS COMPLETELY DEPRESSURED
2.2.1. Maintenance and repair may be carried out only on the shutdown and
entirely vented compressor unit. If necessary isolate all storage
systems and blow-down all condensate traps and heat exchanger
collectors. Open all manual drain valves.
2.2.2. Isolate the equipment electrically by pad-locking the main switch in the
"OFF" position and fixing a corresponding warning sign.
2.2.3. Only use original spare parts and recommended products for
maintenance and repair works on the compressor unit.
2.2.4. Never do work that will produce heat, like welding near oil or gas
systems. Before working on oil or gas tanks empty them and clean
them carefully eg. by a steam jet or purge with nitrogen.
2.2.5. During maintenance and repair work observe strict cleanliness. Keep
impurities away, by covering dismounted parts and free openings with
a clean rag, paper or adhesive tape.
2.2.6. After having finished the works be sure that no tools, loose parts or
cleaning rags have been left on or in the compressor unit, or near the
engine air cleaner.
2.2.7. Do not use easily flammable solving agents for cleaning of parts, until
the unit has cooled thoroughly. After the use of solving agents
carefully rinse the parts and clean them with compressed air.
2.2.8. Be very careful, use eye protection, when working with compressed air
for cleaning equipment.
2.2.9. After modification or repair work on pressure vessels and safety
equipment, such as relief valves, all work must be tested and accepted
by the inspection authority concerned.
2.2.10. The switchboard may be opened only by qualified and authorized
persons. Even if the main switch is set to the "OFF" position, the poles
of the switch and feed cables of the terminal strip are alive. Therefore
do not touch anything on the switchboard, and do not carry out work,
with the mains current supply is not disconnected. Before starting
work check if the system is entirely free of power.
Intermech Ltd.
BBR-6015-2 Compressor Service Manual
Содержание BBR-6015-2
Страница 2: ...REVISIONS RECORD Revision Date Changes Additions Issued 1 March 2006 New edition...
Страница 33: ...Page 33 of 85 4 2 3 Oil Pump Assembly Drawing CRA 357 Intermech Ltd BBR 6015 2 Compressor Service Manual...
Страница 35: ...Page 35 of 85 4 2 5 Oil Pump Relief Valve Drawing CRA 333 Intermech Ltd BBR 6015 2 Compressor Service Manual...
Страница 41: ...Page 41 of 85 4 3 2 Rhino Crankcase Drawing CRA 3602 Intermech Ltd BBR 6015 2 Compressor Service Manual...
Страница 67: ...Page 67 of 85 4 8 4 Cylinder Head Assembly Drawing HEA 6000 Intermech Ltd BBR 6015 2 Compressor Service Manual...
Страница 75: ...Page 75 of 85 4 9 4 Piston Rod Assembly Drawing ROPA 3280 Intermech Ltd BBR 6015 2 Compressor Service Manual...