SECTION 3
Scanner Specifications
SE 1223 Scanner User’s Guide 3-7
d = The housing’s internal optical path (in inches)
from the edge of the housing to the front of the scanner.
A = Scan angle in degrees (53
°
).
So:
L = 1.8 x (D + d) x Tan 26.5
°
)
"
NOTE:
Usable scan length determined by above formula, or 90% of scan
line at any working distance.
The calculation given above is based on good quality sym-
bols in the center of the working range and length of bar
code.
SE 1223 Very High Density (VHD)
Scanner
Table 3-5
SE 1223 VHD Scanner Technical Specifications
Item
Description
Power Requirements
Low Power Current
Motor On Current
Scan Session Current
Motor and Laser On
Surge Current
Max V
cc
Noise Level
5 volt dc
±
10%
65
m
A typ @ 5 V
50 mA typical
100 mA typical
130 mA typical
100 mV point to point
Scan Repetition Rate
36 (± 3)
scans/second (bi-directional)
Laser Power
0.36 mW
± 10%
Scan Angle
3
7
° ±
2
°
Pitch Angle
±6
5
°
from normal straight out