2
IF4 865-868 MHz Reader Quick Start Guide
Packing List
Check to ensure that you receive these items:
S
Intermec
R
IF4 865-868 MHz Reader
S
Compliance Insert
S
Warranty Card
Host Communication
Host communication comes through the 9-pin female D-sub
connector. RS-232 standards are supported as ordered from the
factory or service center.
S
The maximum data rate is 115.2K baud, with 8 data bits, no
parity bit, and 1 stop bit.
S
The maximum RS-232 distance from the reader to the host,
modem, or other physical controller interface is 50 feet (15.2
meters).
RS-232 Connections
Pin Number
Definition
2
TXD (Transmit Data) to the host
3
RXD (Receive Data) from the host
5
Ground
7
CTS (Clear to Send) from the host
8
RTS (Request to Send) to the host
Power Requirements
Power comes in from 8 to 10 volts DC. Your 865-868 MHz
Reader uses less than 2.4 amps. Intermec supplies 9 volts DC at
2.4 amps from Intermec power supply, p/n: 851-067-002.
User I/O
A general purpose I/O (Input/Output) connector provides sig-
nal lines in and out of the reader allowing monitoring and/or
control of external devices or functions.
The connector for this is a 13-pin female circular DIN. The
mating male connector you need for mating with this is an In-
termec p/n: 351-184-001.
Содержание IF4
Страница 1: ...Quick Start Guide IF4 865 868 MHz Reader...