Intermec EasyCoder F4 – Installation & Operation Ed. 3
105
Appendix 3
Interfaces
RS-232 Interface
"uart1:"
The EasyCoder F4 has, as standard, two serial communication
interfaces: RS-232 on "uart1:" and USB (see next page).
Protocol
Default setup:
Baud rate:
9600
Char. length
8 bits
Parity:
None
Stop bits:
1
RTS/CTS Disabled
ENQ/ACK: Disabled
XON/XOFF:
Disabled (both ways)
New Line:
CR/LF
To change the serial interface settings, see Chapter 7, “Setting
Up the Printer”.
Interface Cable
Computer end:
DB-9pin or DB-25pin female connector (PC)
Printer end:
DB-25pin male connector
Host
EasyCoder
F4
Host
Signal DB-9
DB-25 Signal DB-25
DB-25
Signal
1 1
1 1 shield
RXD 2 2 TXD 2 3 RXD
TXD 3 3 RXD 3 2 TXD
CTS 8 4 RTS 4 5 CTS
RTS 7 5 CTS 5 4 RTS
6
DSR
6
20
DTR
GND 5 7
Signal
GND
7 7 GND
16
+
5V
1
16
DSR 6 20 DTR 20 6 DSR
22
RI
22
1
/. The ex5V is limited to 200 mA and is automatically
switched off at overload. It is intended to drive for example an external
alphanumeric keyboard connected to the RS-232 port.
Содержание EasyCoder F4
Страница 1: ...EasyCoderF4 BarCodeLabelPrinter Installation Operation P N 1 960467 02 Edition 3 September 2000 ...
Страница 117: ...Intermec EasyCoder F4 Installation Operation Ed 3 116 Appendix 4 EasySet Bar Code Wand Setup Contrast ...
Страница 118: ...Intermec EasyCoder F4 Installation Operation Ed 3 117 Appendix 4 EasySet Bar Code Wand Setup Media Width Test Labels ...
Страница 119: ...Intermec EasyCoder F4 Installation Operation Ed 3 118 Appendix 4 EasySet Bar Code Wand Setup Media Length ...
Страница 120: ...Intermec EasyCoder F4 Installation Operation Ed 3 119 Appendix 4 EasySet Bar Code Wand Setup Print Speed Media Type ...
Страница 127: ...Intermec EasyCoder F4 Installation Operation Ed 3 126 Notes ...