INTERNAL WIRING

TROUBLE SHOOTING

NOTES AND SPECIFICATIONS

SYMPTOM

CAUSE(S)

CORRECTIVE ACTION

1. Pump will not turn ON/OFF or

1a. Air hose disconnected.

Check hose connections.

operate on low speed only.

1b. Defective air button.

Replace air button - see note 1.

1c. Water in air hose.

Blow-out air hose - see note 2.

1d. Defective pulse switch.

Replace pulse switch - see note 2.

1e. Defective relay.

Replace relay - see note 3.

1f. Air button is too far.

Install larger air button.

2. Timer is not turning Pump

2a. Defective timer.

Replace timer.

ON/OFF for daily filtration.

2b. Defective relay.

Replace relay.

2c. Timer is set to permanent

Set timer to AUTO.

ON/OFF.

2d. No program in timer’s memory.

Set program - see instructions.

2e. Dead memory hold-up battery .      Replace battery.

3. Pump turns ON/OFF by itself.

3a. Defective pulse switch

Replace pulse switch.

3b. Water in air hose

Blow-out air hose - see note 2.

3c. Changing air pressure in air hose

Reroute air hose.

1. An air button with ruptured seal or bellows inside, will 

not produce sufficient air pressure to operate the 
momentary air switch and could lead to total 
break-down.

2. Water in air hose will damage the pulse switch and it is 

caused by a faulty air button (see note 1above) or 
condensation. In either case, it must be drained and the 
cause found and corrected. To reduce condensation,
protect the air hose from exposure to direct sun, ice or 
frequent temperature fluctuations.

3. A defective relay is either due to contact or coil failure. 

Contact failure is caused by over-load or cross-wiring 
and coil failure is caused by 240 volt connected across 
the 120 volt coil or permanently applied 120 volt. (The 
relay is designed for intermittent duty only). 
Permanently applied 120 volt could be the result of 
water in the air hose (see note 2 above) or spa cover 
placed over (and depressing) the air button. In any case,
the cause must be found, corrected and the relay replaced.

3

PULSE

SWITCH

#1

PULSE

SWITCH

#2

MEMORY

HOLD-UP
BATTERY

TIMER

LINE

NEUTRAL

120 V

SUPPLY

WHITE

BLACK

RED

YELLOW

RED

YELLOW 

BLUE

BLACK

GREY

(LOW SPEED)

BLUE (HIGH SPEED) BROWN (FREEZE PROT

.)

AUX.

BLOWER PUMP

RELAY

#2

RELAY

#1

STEPPER RELAY

Содержание RC2403RT

Страница 1: ...eed the maximum ratings of individual components wiring devices and current carrying capacity of conductors 4 For Control grounding bonding installing and the wiring of underwater lights refer to Article 680 of the National Electrical Code or Article 68 of the Canadian Electrical Code 5 The Control should not operate any equipment which would cause bodily injury or property damage should it be act...

Страница 2: ...clear entire memory press key Hold down the CLOCK key while pressing either the HOUR or MINUTE keys Continue pressing until the desired number is shown Then simply lift finger off the CLOCK key to set To Set Program ON OFF times Press TIMER key once to enter into program mode Display will show 1 ON Press the HOUR key and then the MINUTE key to select the desired first ON time Press TIMER key once ...

Страница 3: ... seal or bellows inside will not produce sufficient air pressure to operate the momentary air switch and could lead to total break down 2 Water in air hose will damage the pulse switch and it is caused by a faulty air button see note 1above or condensation In either case it must be drained and the cause found and corrected To reduce condensation protect the air hose from exposure to direct sun ice...

Страница 4: ... WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY MODIFIED TO EXIST ONLY AS CONTAINED IN THIS LIMITED WARRANTY AND SHALL BE OF THE SAME DURATION AS THE WARRANTY PERIOD STATED ABOVE This warranty service is available by either a returning the product to the dealer from whom the unit was purchased or b mailing postage prepaid to the nearest authorized service center listed Please be sure to w...

Отзывы: