background image

INSTALLATION

This Control can operate either a 120 volt or 240 volt, single or two speed pump, together with an air
blower and an auxiliary equipment (booster pump, light etc.).

1. Follow wiring diagram on Page 4 and prepare your 

installation layout. Make sure only copper (solid or
stranded) conductors are used, properly sized and suitable 
for the installation. Each piece of equipment must be
grounded properly. IMPORTANT: NEUTRAL MUST
ALWAYS BE CONNECTED TO THE WHITE LEAD
OF THE CONTROL.

2. Hang Control on a flat vertical surface or other 

support, using hardware suitable for the purpose. 

3. Prepare the necessary conduit runs, including ones for 

the air hoses. Terminate them at both ends and pull-in 
the conductors as specified by the installation layout.

4. Follow wiring diagram, make LINE and LOAD

connections as shown on page 4.
Make sure the installation is securely grounded and 
bonded, if required.

5. Make air hose connections. Follow instructions provided

with air buttons.

6. Check wiring, tightness of connections and grounding.

Close wiring compartment and test installation.

7. Set timer, see instructions below.

SETTING / OPERATING INSTRUCTIONS

2

Indicator LED “ON”
when connected to
power source and
contacts are closed

Display

Reset port 

to cancel all 

prior settings

ON/AUTO/OFF

Select Key

Function Keys

Programming Instructions

To Set or Change the Time of Day: To clear entire
memory, press      key. Hold down the CLOCK key
while pressing either the HOUR or MINUTE keys.
Continue pressing until the desired number is shown.
Then simply lift finger off the CLOCK key to set.

To Set Program (ON/OFF times): Press TIMER key
once to enter into program mode. Display will show 
"1 ON-- --". Press the HOUR key and then the
MINUTE key to select the desired first ON time. Press
TIMER key once. Display will show "1 OFF -- --".
Repeat previous step to select the desired first OFF
time. Repeat the entire sequence to complete up to
eight total ON/OFF times as desired. When program-
ming is done, press the CLOCK key then the SELECT
key repeatedly until the indicator bar is above the word
"AUTO".

To Review Program: Press TIMER key repeatedly.
When done, press CLOCK key to return to the time
of day.

To Cancel/Change Part of the Program: Press Timer
key repeatedly until the particular ON or OFF time
appears. Set new ON or OFF time.

To Override the Automatic Operation one time:
Press OVR. key. 

NOTE: Timer will resume automatic operation with

the next opposite setpoint.

To Override Automatic Operation Permanently:
Press SELECT key to move indicator bar to the
desired ON or OFF position. Note: Timer will not

resume automatic operation until indicator bar is

repositioned above the word AUTO.

TO OPERATE EQUIPMENT, press air button #1 at
spa side to turn ON/OFF jets and blower in the follow-
ing sequence:

SEQUENCE

JETS

BLOWER

1*

OFF

OFF

2

ON

OFF

3

ON

ON

4

OFF

ON

*Home position; automatic ON/OFF operation as set by
the timer.
Press air button #2 to operate auxiliary equipment.

 

Содержание RC2403RT

Страница 1: ...eed the maximum ratings of individual components wiring devices and current carrying capacity of conductors 4 For Control grounding bonding installing and the wiring of underwater lights refer to Article 680 of the National Electrical Code or Article 68 of the Canadian Electrical Code 5 The Control should not operate any equipment which would cause bodily injury or property damage should it be act...

Страница 2: ...clear entire memory press key Hold down the CLOCK key while pressing either the HOUR or MINUTE keys Continue pressing until the desired number is shown Then simply lift finger off the CLOCK key to set To Set Program ON OFF times Press TIMER key once to enter into program mode Display will show 1 ON Press the HOUR key and then the MINUTE key to select the desired first ON time Press TIMER key once ...

Страница 3: ... seal or bellows inside will not produce sufficient air pressure to operate the momentary air switch and could lead to total break down 2 Water in air hose will damage the pulse switch and it is caused by a faulty air button see note 1above or condensation In either case it must be drained and the cause found and corrected To reduce condensation protect the air hose from exposure to direct sun ice...

Страница 4: ... WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY MODIFIED TO EXIST ONLY AS CONTAINED IN THIS LIMITED WARRANTY AND SHALL BE OF THE SAME DURATION AS THE WARRANTY PERIOD STATED ABOVE This warranty service is available by either a returning the product to the dealer from whom the unit was purchased or b mailing postage prepaid to the nearest authorized service center listed Please be sure to w...

Отзывы: