INSTALLATION
This Control can operate either a 120 volt or 240 volt, single or two speed pump, together with an air
blower and an auxiliary equipment (booster pump, light etc.).
1. Follow wiring diagram on Page 4 and prepare your
installation layout. Make sure only copper (solid or
stranded) conductors are used, properly sized and suitable
for the installation. Each piece of equipment must be
grounded properly. IMPORTANT: NEUTRAL MUST
ALWAYS BE CONNECTED TO THE WHITE LEAD
OF THE CONTROL.
2. Hang Control on a flat vertical surface or other
support, using hardware suitable for the purpose.
3. Prepare the necessary conduit runs, including ones for
the air hoses. Terminate them at both ends and pull-in
the conductors as specified by the installation layout.
4. Follow wiring diagram, make LINE and LOAD
connections as shown on page 4.
Make sure the installation is securely grounded and
bonded, if required.
5. Make air hose connections. Follow instructions provided
with air buttons.
6. Check wiring, tightness of connections and grounding.
Close wiring compartment and test installation.
7. Set timer, see instructions below.
SETTING / OPERATING INSTRUCTIONS
2
Indicator LED “ON”
when connected to
power source and
contacts are closed
Display
Reset port
to cancel all
prior settings
ON/AUTO/OFF
Select Key
Function Keys
Programming Instructions
To Set or Change the Time of Day: To clear entire
memory, press key. Hold down the CLOCK key
while pressing either the HOUR or MINUTE keys.
Continue pressing until the desired number is shown.
Then simply lift finger off the CLOCK key to set.
To Set Program (ON/OFF times): Press TIMER key
once to enter into program mode. Display will show
"1 ON-- --". Press the HOUR key and then the
MINUTE key to select the desired first ON time. Press
TIMER key once. Display will show "1 OFF -- --".
Repeat previous step to select the desired first OFF
time. Repeat the entire sequence to complete up to
eight total ON/OFF times as desired. When program-
ming is done, press the CLOCK key then the SELECT
key repeatedly until the indicator bar is above the word
"AUTO".
To Review Program: Press TIMER key repeatedly.
When done, press CLOCK key to return to the time
of day.
To Cancel/Change Part of the Program: Press Timer
key repeatedly until the particular ON or OFF time
appears. Set new ON or OFF time.
To Override the Automatic Operation one time:
Press OVR. key.
NOTE: Timer will resume automatic operation with
the next opposite setpoint.
To Override Automatic Operation Permanently:
Press SELECT key to move indicator bar to the
desired ON or OFF position. Note: Timer will not
resume automatic operation until indicator bar is
repositioned above the word AUTO.
TO OPERATE EQUIPMENT, press air button #1 at
spa side to turn ON/OFF jets and blower in the follow-
ing sequence:
SEQUENCE
JETS
BLOWER
1*
OFF
OFF
2
ON
OFF
3
ON
ON
4
OFF
ON
*Home position; automatic ON/OFF operation as set by
the timer.
Press air button #2 to operate auxiliary equipment.