FOR OUTDOOR USE ONLY
NOT FOR USE IN HAZARDOUS ATMOSPHERES
IMPORTANT: Read instruction sheet carefully before installing fixture.
Retain instructions for future reference.
ELECTRICAL REQUIREMENTS
A qualified electrician should complete all required wiring. This fixture is for use with 120V AC only and must be properly
grounded for safety. A mounting suitable for outdoor use and rated for wet locations is required. Follow all applicable
electrical codes and regulations.
WARNING: Electric shock hazard
Disconnect power at circuit breaker or fuse box before installing or servicing light.
WARNING: Fire hazard
USE MIN 60ºC SUPPLY CONDUCTORS.
CONNECT TO SUPPLY IN EXTERNAL JUNCTION BOX ONLY.
Lamp and housing become very hot during use.
Ensure free air circulation around unit to dissipate heat.
Avoid enclosed locations and locations where flammable debris (leaves, cut grass, etc.) might collect.
Avoid locations where humans or animals might accidentally touch fixture.
WARNING: Explosion hazard
Never operate light without securing the lens door. When light is operating, the gas in the lamp inner arc tube
is at high pressure.
Never operate light if the fixture lens or outer glass envelope of the lamp is broken or missing.
WARNING: Explosion hazard
Wear safety glasses and gloves when handling lamp, High Pressure Sodium outer envelope is under vacuum
and could implode.
MOUNTING & WIRING
1. Screw the threaded mounting arm of the fixture into 1/2” NPS mounting hole on mounting device.
Tighten locknut to secure fixture. See Figure 1.
CAUTION: Mount the fixture so lamp is horizontal. (See Figure 2)
Figure 2
Install with lamp horizontal.
Mounting
Arm Bolt
Locknut
Figure 1
Lens
Door
Clip
Lampholder
Reflector
Hinge
HID Flood Light - FL Series
INSTALLATION INSTRUCTIONS
Lamp Types: High Pressure Sodium 35 Watt, 50 Watt, & 70 Watt
Models: FL035HPS, FL050HPS, & FL070HPS