Note the STOP date is the last day the loads will be inactive or
under special program control. The following day the loads will
resume normal scheduling beginning at 12:00 A.M. Press
PROG
to exit the holiday mode after entering the last holiday.
Holiday schedules and dates will remain in timer memory until
deliberately cleared. For those Holidays whose dates vary from
year to year, you must manually revise the start and stop dates (in
SET UP review) annually. Holidays may not be programmed to
end before their start date and must end by Dec. 31. During days
when the timer is following a holiday schedule the “Ref#” LED
will blink to indicate that Holiday scheduling is in effect.
The
OK
key must be pressed after
each complete entry; pressing it
advances you to the next data prompt. The
OK
key is similar to
an Enter key. After okaying a switching time, the timer automa-
tically prompts for the alternate switching activity; i.e. Off after
On, On after Off (except after a pulse or interval entry). Pressing
the
OK
key without making another switching time entry alter-
nates the On/Off prompt, allowing a succession of Off or On
events.
OK
is the
final step
after programming all steps and
enabling circuits for each switching time/type.
CLEAR clears the last digit entered; additional digits are cleared
from the display each time
CLEAR
is pressed. CLEAR is also used
to clear an error code or message and return the display to the
same data that appeared before attempting to OK the data.
While in Review pressing
CLEAR
deletes the displayed data from
the program for the load(s) selected with
Enable
. Press
REV
to
continue Review.
COPY allows you to use the same schedule for groups of days
other than those available on the keypad (WKDYs, WKNDs or
ALL). Simply press
COPY
after entering a schedule for a specific
day, and at the DAY prompt key in the day you wish to copy to,
then press
OK
. You may also copy a day that was previously
programmed by pressing that day’s key, pressing the
OK
key, then
the
COPY
key.
OK
CLEAR
COPY
HELP
8
(Clock adjustment for Daylight Savings Time (DST) is automatic;
see Special Instructions for override if DST adjustment is not
required, such as in Arizona, Hawaii and parts of Indiana.
The clock time will be adjusted by 1 hour on the first Sunday of
April and the last Sunday of October at 2:00 A.M. Due to un-
expected results, it is recommended you do not attempt pro-
gramming from 12:00 midnight to 2:00 A.M. on these two days.)
PROG (Program) and SET UP
return you to the beginning of these
categories. Press
PROG
to select a new day/day group when
programming of a selected day/day group is complete, or to skip
Astro and/or Holiday prompts during SET UP.
REV (Review) allows you to check SET UP or PROGRAM data.
The holidays will review in chronological order regardless of the
order in which they were entered. CLEAR is used during Review to
delete displayed data if changes are required.
The Holiday (HLDY) feature allows the timer to follow special
schedules on selected days or periods of days, based on the date
instead of the usual 7 days of the week. Although Holiday schedules
are normally used to modify or suspend regular weekly switching
activity on actual holidays, the Holiday feature also allows a variety
of special scheduling options that are not satisfied by the 7-day
repeating schedule. See Programming Examples supplement for
details. Each holiday may be one day long or as many days as
necessary. Although each has a reference number (1–99) that you
assign, Holidays occur and review in chronological order, so the
order of the reference numbers does not matter.
HLDY (Holiday) allows you to set up or review Holiday data. If a
holiday is a single day, press
OK
when prompted for the STOP
date, or enter the same date. Holiday scheduling applies to all 4
circuits. If you need to switch loads on a holiday, press
PROGRAM
,
press
HLDY
, enter the reference number 1–99 for that holiday,
then press
OK
. Program the holiday load schedule just as you
would any day or day group. If you do not program switching times
for holidays, the loads will be inactive during the holiday period; all
loads will remain in the state they were at 11:59 PM on the day
preceding the start of the holiday. You may program Off events at
12:00 A.M. on holidays to guarantee loads are off during holidays.
9
Next Generation
PROG
REV
SET UP
HLDY