36
NOTE:
If you need more programming assistance, request form
#158ET9311, Programming Examples, which contains step-by-
step instructions for several complex programs.
ERROR MESSAGES
Pressing
HELP
when an error code is displayed will cause an error
message and recommended action to scroll on display. Press any
key to stop message and restore pre-error display.
ERR 01
Too many keys pressed or
HELP
key not pressed first
ERR 02
Numeric entry not applicable
ERR 03
AM - PM
key entry not applicable
ERR 04
Clock time not setup
ERR 05
Clock date not setup
ERR 06
ASTRO
not setup
ERR 07
HOLIDAY
not setup
ERR 08
OVERRIDE
not setup
ERR 09
ASTRO
entry not applicable
ERR 10
COPY
key not applicable
ERR 11
Unable to clear a set point in week long review mode –
set points may only be cleared from an individual
day’s program
ERR 12
Internal calculation error – may not be recoverable –
reset the time switch
ERR 13
Day groups may not be copied to or from
ERR 14
No
ON
or
OFF
time entry is allowed when entering an
Astro Set Point
ERR 15
A day may not be copied to itself or to a day which has
already been programmed.
ERR 16
February 29th is only permitted in leap year
ERR 17
No circuit selected–select a circuit using the circuit
enable switches
ERR 18
Astro entry is out of limits–
SUNRISE
must be before
noon and
SUNSET
must be after noon.
SUNSET
must
not be within 5 hours of
SUNRISE
.
Problem
Solution(s)
Switch On/
•
After any Pulse or Interval entry, the Switch
Off Display
On or Switch Off LED does not alternate,
Doesn’t
since most Pulse or Interval applications
Alternate
require only ON or OFF. Press
OK
without a
During
time entry to alternate the Switch On/Off
Programming
display if required.
Some •
All review should be done with only one circuit
Switching
enabled at a time. If more than one is enabled,
Times Don’t
only events common to the circuits selected
Show During
will show during review. To see all possible
Review
scheduled events, the
week long
review should
be used. Events programmed via Day Group
or Copy Day methods will not show when
reviewing individual days or vice versa.
Difficulty in
•
When using pulsed output for switching a
Programming/
latching relay or contactor without “self-
Reviewing On/
clearing” contacts, one circuit is dedicated to
Off Latching
the load Turn On Pulse and another to the
Pulse
Turn Off Pulse. The pulses are created by
or
turning the respective circuits On momentarily
Output to
(1 to 2 sec.). Therefore all events must be
Latching
programmed and will review as On Pulses.
Contactor
The On time(s) of the controlled load will be
Remains On
shown as On Pulses for one circuit and the Off
After an Off
time(s) will review as On Pulses for the other
Pulse
circuit.
Note: Using the manual On/Off keys to
switch this type of contactor On or Off may not
provide the expected result and may cause damage
to the contactor coil. For this application external
Momentary Pushbutton may be added for both
circuits or the circuits may be programmed for
override pulses. Refer to the Programming
Examples booklet for more information.
Next Generation