![Interlogix xgen Скачать руководство пользователя страница 13](http://html.mh-extra.com/html/interlogix/xgen/xgen_installation-and-programming-manual_2077298013.webp)
xGen Installation & Programming Guide
11
NXG-003 xGen Metal Enclosure
A spare metal enclosure is available for those installations where additional xGen
zone and/or output expanders are required or in case a larger backup battery is
required. The xGen NXG-003 metal enclosure includes a tamper switch and one
metal DIN rail. A second metal DIN rail (NXG-003-DIN) can be added if required
but in that case a backup battery of max 12 VDC / 7 Ah will fit the enclosure.
The enclosure should be installed in accordance with EN50131-1 Environmental
Class II to provide operating conditions within:
• Temperature range: -10 to +55°C.
• Humidity range: Average 93% relative humidity, non-condensing
To install a module, release the locking tab(s) and place on the DIN rail then
push the locking tab(s) to secure the module. To remove a module, use a small
flat-blade screwdriver to release the locking tab(s) on the xGen module then
remove from the DIN rail. Refer to module installation manual for further details.
Power Requirements
The xGen intrusion panel family is designed to be used with a 40 VA TD300-
E101F transformer (p/n NXG-003-X) which is included in the xGen panel. This
transformer includes a 500 mA 250 VAC fast blow replaceable fuse on the
terminal block.
Содержание xgen
Страница 1: ...xGen Installation Programming Guide P N 230410 REV A ISS 31AUG15 ...
Страница 25: ...xGen Installation Programming Guide 23 SIA and CID reporting code descriptions ...
Страница 26: ...24 xGen Installation Programming Guide ...
Страница 27: ...xGen Installation Programming Guide 25 ...
Страница 28: ...26 xGen Installation Programming Guide ...
Страница 29: ...xGen Installation Programming Guide 27 ...
Страница 57: ...xGen Installation Programming Guide 55 Programming Guide for xGen ...
Страница 62: ...60 xGen Installation Programming Guide Web Page ...
Страница 77: ...xGen Installation Programming Guide 75 Instructions 1 Go to Zone Type 2 Go to Zone Options ...
Страница 86: ...84 xGen Installation Programming Guide Webpage ...