TruPortal IP-based Single Door Controller Quick Reference
9
Specifications
Regulatory Information
Contact Information
Customer support:
© 30OCT13 United Technologies Corporation
Interlogix is part of UTC Climate, Controls & Security, a unit of
United Technologies Corporation. All rights reserved.
Document number: 460939301C - October 2013
Dimensions (Height ×
Width × Depth)
10.15 in. x 9.15 in. x 3.04 in.
(258 mm x 232 mm x 77 mm)
Operating
environment
temperature
[1]
1. +32° to +120° F (0° to +49° C)
+35 to +122° F (+2 to +50° C)
Humidity range
[2]
2. Up to 85% non-condensing
5 to 95% non-condensing
Thermal air cooling
At least 6 in. (15.2 cm) of clearance is required on all
four sides of the enclosure.
Power input
requirements
IEEE802.3af 16 watt Class 0 Mode A and B PoE/
PSE) on Standard Category 5 (CAT 5) Ethernet cable
Note:
By Ethernet standards, the maximum cable
length is limited to 328 ft. (100 m) between the PoE
source and the IPSDC.
-or-
Auxiliary 24 VDC 1 A local supply (24 watts).
IPSDC to reader
cabling
Reader voltage: 12 VDC
Note:
If the cable distance is greater than 500 feet
(152.4 m), but less than or equal to 2000 feet
(609.6m) and/or the current per reader is greater than
150 mA, use 20 AWG shielded cable.
If the cable distance is less than 500 feet (152.4 m),
use 22 AWG shielded cable.
Recommended:
Use 20 AWG shielded cable to wire
reader, DOs, and DIs. Use plenum-rated cable for
applications where cable will run above a false (i.e.,
suspended) ceiling in the air circulation space.
Recommended:
Alpha Xtra Guard1 foil shield cable,
non-plenum-rated, or Belden-series security and
alarm cable (commercial applications shielded),
plenum-rated.
Readers
Maximum number of readers supported: 2
Reader technology supported: Wiegand
Output devices maximum ratings: Door DO (Reader
LED) = 20.mA @ 12 VDC maximum; Door strike
(DO) relay = 2 A @ 28 VDC or 30 VAC maximum
Strikes
Maximum current: 390 mA per strike output. See
Table 2 on page 2 for recommended strike models
and associated power requirements.
Network
requirements
Although IPSDCs are equipped with a fallback mode,
they should be placed on a network with an adequate
reliability rate. (A network reliability rate of 99.98
percent is typical for mission-critical operations.)
If a typical Mean Time To Repair (MTTR) goal is one
hour, then using the 99.98% reliability rate equates to
a mean network reliability, or Mean Time Between
Failure (MTBF), goal of approximately 5,000 hours (or
1hr/.0002). In other words, the network that the
IPSDC is being placed on (from the door controller to
the System Controller), should not fail more often than
once every 5,000 hours (or approximately 208 days)
on average.
UL evaluation for UL-Listed Installations:
Manufacturer Interlogix
Headquarters and Regulatory responsibility:
Interlogix
3211 Progress Dr.
Lincolnton, NC 28092 USA
EU authorized manufacturing representative:
UTC Climate, Controls & Security B.V.,
Kelvinstraat 7, 6003 DH Weert,
The Netherlands
Year of
manufacture
The first two digits of the product serial number (located
on the product identification label) are the year of
manufacture.
North American
standards
UL 294
FCC
compliance
This device complies with part 15 of the FCC Rules.
Operation is subject to the following two conditions: (1)
This device may not cause harmful interference, and (2)
this device must accept any interference received,
including interference that may cause undesired
operation.
Environmental
Class
UL: Indoor dry
Certification
European Union
directives
We declare under our sole responsibility that this product
is in conformity with Directive 1999/5/EC (R&TTE), 2004/
108/EC (EMC), 2006/95/EC (LVD), and 93/68/EEC
(Marking) based on test results using harmonized
standards in accordance with the Directives mentioned.