Partition 1
Figure 10: Wiring a speaker to a PIV module (partition 1)
Not Used
Hardwire Interior
Speaker (60-528)
Speaker
Panel
Terminals
Phone Interface/Voice
Module Terminal Strip 1
Phone Interface/Voice
Module Terminal Strip 2
All other partitions
Figure 11: Wiring a speaker to the PIV module (all other partitions)
Not Used
Hardwire Interior
Speaker (60-528)
Phone Interface/Voice
Module Terminal Strip 1
Phone Interface/Voice
Module Terminal Strip 2
Setting the Module Unit Number
In order to ensure proper communication, each panel-
connected bus module must have a different unit number.
Concord (v2.0-later), Concord 4, and Concord
Express (v4) Panels
For Concord (v2.0-later), Concord 4, and Concord Express
(v4) panels, unit numbers are automatically learned by the
panel after the system receives power. If using one module per
partition, the panel automatically assigns each module a
partition number.
Concord Panels (v1.0–1.6)
A module can be set to any unit number (0-15) using the
module DIP switches. If no other bus modules are installed in a
system, the default setting (0) can be used.
If using one module per partition, the lower unit number is
assigned to Partition 1; the higher unit number is assigned to
Partition 2.
Note
: Because unit numbers for Concord RF receivers are
factory set to 15, do not use this unit number setting.
Setting DIP Switches
On the module, locate the DIP switches (see Figure 1 on page
1). Next, set the desired unit number from 0 to 15 (see
Figure 12 below) before you turn the power on.
Note
: DIP switches 1–4 are not used and must be set to OFF.
Figure 12: Unit number DIP switch settings
ADDRESS 0
1 2 3 4 5 6 7 8
ON
ADDRESS 1
1 2 3 4 5 6 7 8
ON
ADDRESS 2
1 2 3 4 5 6 7 8
ON
ADDRESS 3
1 2 3 4 5 6 7 8
ON
ADDRESS 4
1 2 3 4 5 6 7 8
ON
ADDRESS 5
1 2 3 4 5 6 7 8
ON
ADDRESS 6
1 2 3 4 5 6 7 8
ON
ADDRESS 7
1 2 3 4 5 6 7 8
ON
ADDRESS 8
1 2 3 4 5 6 7 8
ON
ADDRESS 9
1 2 3 4 5 6 7 8
ON
ADDRESS 10
1 2 3 4 5 6 7 8
ON
ADDRESS 11
1 2 3 4 5 6 7 8
ON
ADDRESS 12
1 2 3 4 5 6 7 8
ON
ADDRESS 13
1 2 3 4 5 6 7 8
ON
ADDRESS 14
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
ON
ADDRESS 15--Do not use in Concord RF systems.
Power Up and Bus Communication
When powering the system or verifying bus communications,
follow the procedures listed below:
Note
: To enter program mode and verify unit numbers, you
must connect an alphanumeric touchpad to the Concord panel.
1. Verify all wiring at the panel and module is correct.
2. Connect the panel’s backup battery and plug in the AC
power transformer.
3. Verify the module’s status LED is on.
SuperBus 2000 Phone Interface/Voice Module Installation Instructions
5