Concord systems can accommodate one PIV module per 

partition. For multiple partition installations, each module 

must be connected to a separate phone line and speaker.  

• 

Give your customer the ability to unplug their system by 

connecting the phone line with an RJ-31X jack. This 

ensures your customer can unplug the system in cases of 

malfunction where they must also use the phone.  

• 

Mount the module inside the panel cabinet or use the 

optional plastic wall-mount housing (part no. 60-800).  

• 

Use four-conductor, 22-gauge or larger diameter stranded 

wire to connect the module to the panel.  

• 

Install the module inside the panel cabinet or as close to 

the cabinet as possible.  

• 

Set each bus module with different bus unit numbers 

(must be manually set for Concord panels v1.0-1.6).  

• 

Remember that the module draws a maximum 600 mA 

from the panel’s power supply.  

• 

When using panel power to supply bus or hardwired 

devices, 

do not 

exceed the panel’s total power output. 

Refer to specific panel 

Installation Instructions 

for further 

detail. 

Tools and supplies 

• 

Slotted screwdrivers  

• 

3/8”-drive drill and drill bits  

• 

Wire cutter/stripper  

• 

Screws and anchors (included)  

• 

Optional plastic housing (60-800, not included)  

• 

Four-conductor, 22-gauge or larger stranded wire  

• 

RJ-31X Phone Jack (not included)  

• 

DB-8 Cord (included with Concord cabinet)  

• 

Support standoffs (included with Concord cabinet) 

Installation 

When installing the PIV module, mount the module inside a 

panel cabinet or on a wall. 

Caution: 

To prevent damage to the panel or module, remove 

the panel’s AC power transformer and disconnect the backup 

battery before installation. 

You must be free of static electricity when handling electronic 

equipment. Touch a grounded metal surface before touching a 

circuit board. 

Mounting the Module in a Concord Panel Cabinet:  

1.  Remove panel AC power and disconnect the backup 

battery. 

2.  Install support standoffs (see Figure 2 below). 

Figure 2: Installing support standoffs 

Support

Standoffs

 

3.  On the panel cabinet, slide the top of the backplate on to 

the module’s center and top-left mounting clips (see 

Figure 3 below). 

Figure 3: Mounting the module inside a panel cabinet 

Module Mounting

Clips (6)

Card on Module

Back Plates

Panel Cabinet

(Cover not shown)

Support

Standoff

 

4.  Raise the backplate assembly until it rests on the cabinet’s 

left wall tab and the standoffs align with the backplate’s 

lower holes (see detail in Figure 3 above). 

Mounting the Module with Optional Plastic Housing:

 

1.  Loosen cover screws and remove cover (see Figure 4 on 

page 3). 

2  

SuperBus 2000 Phone Interface/Voice Module Installation Instructions 

Содержание SuperBus 2000 PIV

Страница 1: ...ically learned by the panel Potential identical unit number conflicts and the need to manually set DIP switches are eliminated Older SuperBus panels can communicate with the PIV module by manually setting the module s DIP switches SuperBus 2000 Panels Concord v2 0 later Concord 4 Concord Express v4 SuperBus Panels Concord v1 0 1 6 Features The PIV module includes the following features User adjust...

Страница 2: ...d Four conductor 22 gauge or larger stranded wire RJ 31X Phone Jack not included DB 8 Cord included with Concord cabinet Support standoffs included with Concord cabinet Installation When installing the PIV module mount the module inside a panel cabinet or on a wall Caution To prevent damage to the panel or module remove the panel s AC power transformer and disconnect the backup battery before inst...

Страница 3: ...ollowing guidelines prior to installing an RJ 31X phone jack Do not mount an RJ 31X jack CA 38A in Canada more than five feet away from the panel Connect the panel to a standard analog phone line Ensure the analog line provides 48V DC and can increase from 89V to 130V DC while the line is in use Note Concord panels cannot be used on a digital or PBX phone line These line types are designed only fo...

Страница 4: ...ct the backup battery prior to wiring Wiring Power and Bus All partitions Figure 7 Wiring the PIV module to panel power and Bus terminals Panel Terminals Phone Interface Voice Module Terminal Strip 1 Phone Interface Voice Module Terminal Strip 2 Wiring phone line Note All partitions must be wired to separate phone lines Partition 1 Figure 8 Wiring the PIV module to a phone line partition 1 Phone I...

Страница 5: ...ned to Partition 2 Note Because unit numbers for Concord RF receivers are factory set to 15 do not use this unit number setting Setting DIP Switches On the module locate the DIP switches see Figure 1 on page 1 Next set the desired unit number from 0 to 15 see Figure 12 below before you turn the power on Note DIP switches 1 4 are not used and must be set to OFF Figure 12 Unit number DIP switch sett...

Страница 6: ...f the LED remains off replace the module The status LED remains lit but does not flash 1 Verify the panel recognizes the module see panel Installation Instructions 2 Check for proper wiring connections 3 If the LED fails to flash replace the module The module has a random inconsistent behavior 1 Check for proper wiring connections 2 Verify the panel recognizes the module see panel Installation Ins...

Страница 7: ... to separate outlets on different branch circuits Consult the dealer or an experienced radio TV technician for help FCC Part 68 This equipment complies with part 68 of the FCC Rules Located on this equipment is a label that contains among other information the FCC registration number and the ringer equivalence number REN for this equipment If requested this information must be provided to the tele...

Отзывы: