Configuring IP Address 

3.  At the “

POC2502 Series#

” prompt, enter “

configure

”. 

 

4. At the “

POC2502 Series (config)#

” prompt, enter the 

following command and press 

<Enter>

 as shown in Figure 

4. 

 

POC2502 Series(config)# 

ip address 192.168.1.100 

mask 255.255.255.0 

POC2502 Series(config)# 

ip default-gateway 

192.168.1.254 

The previous command would apply the following settings for 
the Switch. 

IP Address: 192.168.1.100 

Subnet Mask: 255.255.255.0 

Gateway: 192.168.1.254 

  

 

 

 

Figure 4:

 IP Address Screen 

5. Repeat Step 1 to check if the IP address is changed. 

If the IP is successfully configured, the POC2502 Managed 

Switch will apply the new IP address setting immediately. You 

can access the Web interface of the POC2502 Managed 

Switch through the new IP address. 

 

 

If you are not familiar with the console command or 

the related parameter, enter “

?

” anytime in console 

to get the help description. 

Saving the Configuration via the Console 

In the switch, the running configuration file stores in the RAM. 
In the current version, the running configuration sequence 
running-config  can be saved from the RAM to FLASH by 

writing 

the command or 

copying 

the

 running-config startup-

config

  command, so that the running configuration sequence 

becomes the startup configuration file, which is called 
configuration save. 

1. 

At the “

POC2502 Series#

” prompt, enter

 

copy running-

config startup-config

” as shown in Figure 5. 

  

 

Figure 5:

 The Configuration Screen 

 

Starting Web Management

 

The following shows how to start up the 

Web Management

 of 

the POC2502 Managed Switch. Note, the POC2502 Managed 

Switch is configured   through an Ethernet connection. Please 

make sure the manager PC must  be set on the same 

IP 

subnet address

For example, the default IP address of the POC2502 Managed 

Switch is 

192.168.0.100

, then the manager PC should be set 

at 

192.168.0.x

  (where x is a number between 1 and 254, 

except 100), and the default subnet mask is 255.255.255.0. 

 

 

 

 

 

Figure 6

: IP Management Diagram 

Logging in to the Managed Switch                                   

1.  Use Internet Explorer  8.0 or above Web browser  and 

enter IP address 

http://192.168.0.100

 to access the Web 

interface.  

2.  When the following dialog box appears, please enter the 

default user name and password “

admin

”. The login 

screen in Figure 7 appears. 

Default Username: 

admin

 

Default Password: 

admin

 

 

Figure 7:

 Login Screen 

IFS POC2502 Series Quick Start Guide  

Содержание POC2502 Series

Страница 1: ... POC2502 Managed Switch and carefully unpack it The box should contain the following items The POC2502 Managed Switch x 1 Quick Installation Guide x 1 Rubber Feet x 4 Power Cord x 1 RS 232 to RJ45 Console Cable x 1 SFP Dust Cap x 2 BNC Female Dust Cap x 8 POC2502 8CXP BNC Female Dust Cap x 16 POC2502 16CXP Warning Sticker x 8 POC2502 8CXP Warning Sticker x 16 POC2502 16CXP Rack mount Accessory Kit...

Страница 2: ...play running testing procedures Then the following message asks to log in user name and password The factory default user name and password are shown as follows and the login screen in Figure 3 appears Username admin Password admin Figure 3 POC2502 Managed Switch Console Login Screen The user can now enter commands to manage the Managed Switch For a detailed description of the commands please refe...

Страница 3: ...rom the RAM to FLASH by writing the command or copying the running config startup config command so that the running configuration sequence becomes the startup configuration file which is called configuration save 1 At the POC2502 Series prompt enter copy running config startup config as shown in Figure 5 Figure 5 The Configuration Screen Starting Web Management The following shows how to start up...

Страница 4: ...t the coaxial cable with one side being the 75ΩBNC plug connector into the Long Reach Ethernet coaxial interface 2 Connect the other end of the cable to a device with Long Reach Ethernet coaxial Extender installed 3 Tight the BNC male connector gently 4 Enable Long Reach Power over Ethernet function for the all POC2502 ports from Web UI 5 Check the LNK LED of the Long Reach Power over Ethernet int...

Страница 5: ...ectricity Do not touch center pin or connect this end to any non IFS POC2502 equipment Saving the Configuration via the Web In the POC2502 Managed Switch the running configuration file stores in the RAM In the current version the running configuration sequence of running config can be saved from the RAM to FLASH by Save Configurations to FLASH function so that the running configuration sequence be...

Страница 6: ...s rebooted you can login the management Web interface within the same subnet of 192 168 0 xx Figure 10 POC2502 8CXP Reset Button This reset would be the same on the POC2502 16CXP 2T 2S Contact information www interlogix com or www utcfssecurityproducts eu For customer support see www interlogix com customer support 2015 United Technologies Corporation Interlogix is part of UTC Climate Controls Sec...

Отзывы: