It is recommended to use Internet Explore 8.0 or 

above to access the Managed Switch. If the Web 

interface of the Managed Switch is not accessible, 

please turn off the anti-virus software or firewall 

and then try it again.

 

Terminal Setup 

To configure the system, connect a serial cable to a 

COM port

 

on a PC or notebook computer and to RJ45 type of serial port 

of the Managed Switch.  
 

 

 

Figure 1:

  Managed Switch Console Connectivity 

 

A terminal program is required to make the software 

connection to the Managed Switch.  

1.  Run terminal program

 

on the OS. 

2.  When the following screen appears, make sure that the 

COM port should be configured as: 

 

 Baud 

 

: 115200 

 Data bits  

: 8 

 Parity 

 

: None  

 Stop bits  

: 1 

 Flow control : None  

 

 

 

 

 

Figure 2:

 COM Port Configuration 

 

Logon to Console 

Once the terminal is connected to the device, power on the 

Managed Switch and the terminal will display “running testing 

procedures”. Then, the following message asks to log-in user 

name and password. The factory default user name and 

password are shown as follows and the login screen in Figure 

3  appears.  

Username: 

admin

 

Password: 

admin

 

            

 

Figure 3: 

POC2502  Managed Switch Console Login Screen 

 

The user can now enter commands to manage the Managed 

Switch. For a detailed description of the commands, please 

refer to the following chapters. 

 

 

1.  For security reasons, please change and 

memorize the new password after this first 

setup. 

2.  Only accept command in lowercase letter 

under console interface. 

Configuring IP Address 

The Managed Switch is shipped with default IP address shown 

below.  

IP Address: 

192.168.0.100 

Subnet Mask:

 255.255.255.0

 

To check the current IP address or modify a new IP address 

for the Switch, please use the procedures as follows: 

 

Show the current IP Address 

1. 

At the 

“POC2502 Series#”

 prompt, enter

 “show ip ”. 

 

2. 

The screen displays the current IP address as shown in 
Figure 3. 

       

 

Figure 3:

 IP Information Screen 

 

2  

IFS POC2502 Series Quick Start Guide 

Содержание POC2502 Series

Страница 1: ... POC2502 Managed Switch and carefully unpack it The box should contain the following items The POC2502 Managed Switch x 1 Quick Installation Guide x 1 Rubber Feet x 4 Power Cord x 1 RS 232 to RJ45 Console Cable x 1 SFP Dust Cap x 2 BNC Female Dust Cap x 8 POC2502 8CXP BNC Female Dust Cap x 16 POC2502 16CXP Warning Sticker x 8 POC2502 8CXP Warning Sticker x 16 POC2502 16CXP Rack mount Accessory Kit...

Страница 2: ...play running testing procedures Then the following message asks to log in user name and password The factory default user name and password are shown as follows and the login screen in Figure 3 appears Username admin Password admin Figure 3 POC2502 Managed Switch Console Login Screen The user can now enter commands to manage the Managed Switch For a detailed description of the commands please refe...

Страница 3: ...rom the RAM to FLASH by writing the command or copying the running config startup config command so that the running configuration sequence becomes the startup configuration file which is called configuration save 1 At the POC2502 Series prompt enter copy running config startup config as shown in Figure 5 Figure 5 The Configuration Screen Starting Web Management The following shows how to start up...

Страница 4: ...t the coaxial cable with one side being the 75ΩBNC plug connector into the Long Reach Ethernet coaxial interface 2 Connect the other end of the cable to a device with Long Reach Ethernet coaxial Extender installed 3 Tight the BNC male connector gently 4 Enable Long Reach Power over Ethernet function for the all POC2502 ports from Web UI 5 Check the LNK LED of the Long Reach Power over Ethernet int...

Страница 5: ...ectricity Do not touch center pin or connect this end to any non IFS POC2502 equipment Saving the Configuration via the Web In the POC2502 Managed Switch the running configuration file stores in the RAM In the current version the running configuration sequence of running config can be saved from the RAM to FLASH by Save Configurations to FLASH function so that the running configuration sequence be...

Страница 6: ...s rebooted you can login the management Web interface within the same subnet of 192 168 0 xx Figure 10 POC2502 8CXP Reset Button This reset would be the same on the POC2502 16CXP 2T 2S Contact information www interlogix com or www utcfssecurityproducts eu For customer support see www interlogix com customer support 2015 United Technologies Corporation Interlogix is part of UTC Climate Controls Sec...

Отзывы: