background image

 

6 / 6 

 

P/N 1073550-EN • REV B • ISS 01FEB19 

Contact information 

North America 

+1 855.286.8889  

[email protected] 

www.interlogix.com/support 

Latin America 

+1 561-998-6114 

[email protected] 

Europe, Middle East, and Africa 

Select 

Contact Us

 at www.firesecurityproducts.com 

Australia 

[email protected] 

www.utcfs.com.au/support 

 

Содержание NS3552-8P-2S-V2

Страница 1: ...anagement purposes The following equipment is necessary for further management Workstations running Windows XP 2003 Vista 7 8 2008 10 MAC OS X or later Linux UNIX or other platforms are compatible with TCP IP protocols Workstations are installed with Ethernet NIC Network Interface Card Serial port connection Terminal The above workstations come with a COM Port DB9 or USB to RS 232 converter The ab...

Страница 2: ...not mount the switch horizontally as this does not allow air to flow up into the device and will result in damage to the switch Do not tie DC1 to DC2 DC2 is for secondary power redundancy Do not plug DC power into the device while the AC power cord is plugged in This is not a hot swappable switch Hot swapping this device will result in damage DIN rail mounting installation To replace the wall moun...

Страница 3: ...ivity A terminal program is required to make the software connected to the industrial managed switch Windows Hyper Terminal program may be a good choice The Hyper Terminal can be accessed from the Start menu 1 Click Start Programs Accessories Hyper Terminal 2 When the following screen appears ensure that the COM port is configured as shown below Click OK when finished with configuration 3 Log in t...

Страница 4: ...ch through the new IP address Note If unfamiliar with the console command or the related parameter type help in the console to obtain the Help description Starting web management The section describes how to start up the web management function for the industrial managed switch Note that the industrial managed switch is configured through an Ethernet connection Ensure that the manager computer is ...

Страница 5: ...g command After doing this the running configuration sequence becomes the startup configuration file i e the saved configuration To save all applied changes and set the current configuration as a startup configuration the startup configuration file is loaded automatically across a system reboot 1 Click System Save Startup Config 2 Click the Save Configuration button Resetting the switch to default...

Страница 6: ...286 8889 E techsupport interlogix com W www interlogix com support Latin America T 1 561 998 6114 E latam interlogix com Europe Middle East and Africa W Select Contact Us at www firesecurityproducts com Australia E security tech support interlogix com au W www utcfs com au support ...

Отзывы: