Chapter 4: Web configuration
92
NS3552-8P-2S-V2 User Manual
Object
Description
Current Link Speed
Provides the current link speed of the port.
Configured Link Speed
Select any available link speed for the given switch port. Draw the
menu bar to select the mode.
All
: Set up all ports with the same setting.
Auto Copper
: Set up auto negotiation for the copper interface.
Auto Fiber
: Set up auto negotiation for the copper interface.
10 Half
: Force sets 10 Mbps/Half-Duplex mode.
10 Full
: Force sets 10 Mbps/Full-Duplex mode.
100M Half
: Force sets 100 Mbps/Half-Duplex mode.
100 Full
: Force sets 100 Mbps/Full-Duplex mode.
1000 Full
: Force sets 1000 Mbps/Full-Duplex mode.
Disable
: Shut down the port manually.
Flow Control
When
Auto Speed
is selected on a port, this section indicates the
flow control capability that is advertised to the link partner. When a
fixed-speed setting is selected, that is what is used. The Current Rx
column indicates if pause frames on the port are obeyed, and the
Current Tx column indicates whether pause frames on the port are
transmitted. The Rx and Tx settings are determined by the result of
the last Auto-Negotiation.
Check the configured column to use flow control. This setting is
related to the setting for Configured Link Speed.
Maximum Frame Size
Enter the maximum frame size allowed for the switch port, including
FCS. The allowed range is 1518 bytes to 9600 bytes.
Excessive Collision Mode
Configure port transmit collision behavior.
Discard
: Discard frame after 16 collisions (default).
Restart
: Restart back off algorithm after 16 collisions.
Power Control
The Usage column shows the current percentage of the power
consumption per port. The Configured column allows for changing the
power savings mode parameters per port.
Disabled
: All power saving mechanisms are disabled.
ActiPHY
: Link down power savings is enabled.
PerfectReach
: Link up power savings is enabled.
Enabled
: Both link up and link down power savings are enabled.
Note:
If setting each port to run at 100M full-, 100M half-, 10M full-, and 10M half-speed
modes, the auto-MDIX function will be disabled.
Buttons
• Click
Save
to save changes.
• Click
Reset
to undo any changes made locally and revert to previously saved
values.
• Click
Refresh
to refresh the page and undo all local changes.
Содержание NS3552-8P-2S-V2
Страница 1: ...NS3552 8P 2S V2 User Manual P N 1073552 EN REV B ISS 25JAN19 ...
Страница 41: ...Chapter 3 Switch management NS3552 8P 2S V2 User Manual 39 ...
Страница 73: ...Chapter 4 Web configuration NS3552 8P 2S V2 User Manual 71 ...
Страница 147: ...Chapter 4 Web configuration NS3552 8P 2S V2 User Manual 145 ...
Страница 153: ...Chapter 4 Web configuration NS3552 8P 2S V2 User Manual 151 Multicast flooding IGMP snooping multicast stream control ...
Страница 511: ......