Wall-mount plate mounting 

To install the 

industrial 

PoE+ switch on the wall, 

follow the 

steps 

below

1. 

Remove the DIN

-r

ail from the industrial 

PoE+ switch. 

L

oosen 

the screws to remove the DIN

-rail. 

2.  Place the wall-

mount plate

s on the rear panel 

of the 

industrial 

PoE+ switch 

as shown below

 

3.  Use the screws to screw the wall-

mount plate

s on the 

industrial 

PoE+ switch. 

 

4. 

Use the hook holes at the corners of the wall

-

mount plate

to hang the 

industrial 

PoE+ switch on the wall.

 

5.  To remove the wall-

mount p

lates, reverse the steps 

above.

 

Installation Steps 

This section describes the functionalities of the Industrial PoE+ 

components and guides how to install it on the desktop. Basic 

knowledge of networking is assumed. Please read this chapter 

completely before installation.

 

1.  Unpack the 

industrial 

PoE+ switch.

 

2. 

Check the DIN

-

Rail 

that is pre-installed on the 

industrial 

PoE+ switch. 

(Please refer to DIN

-

Rail Mounti

ng section 

for DIN

-

Rail installation

If you want to wall mount the 

industrial 

PoE+ switch

, then please refer to Wall Mount 

Plate Mounting section for specific instructions

3.  To hang the 

industrial 

PoE+ switch 

on the DIN

-

Rail track 

or wal

l, please refer to the Mounting section.

 

4.  Power on the 

industrial 

PoE+ switch. 

(Please refer to the 

Wiring the Power Inputs section

 

for power input)

 The 

power LED on the industrial 

PoE+ switch 

illuminates. 

Please refer to the LED i

ndicato

rs section for LED 

definitions

5.  Prepare the twisted-

pair, straight through Category 5 cable 

for Ethernet connection.

 

6. 

Insert one side of Category 5 cables into the industrial 

PoE+ switch 

Ethernet port (RJ

-45 port) and the other side 

to the network device 

Ethernet port (RJ

-

45 port), ex: 

S

witch, PC, 

or Server. The UTP port (RJ

-

45) LED on the 

industrial 

PoE+ switch 

illuminates

 

when the cable 

is 

connected to the network d

evice. Please refer to the LED 

i

ndicators section for LED definitions

7. 

Insert 

the 

fiber cable from the industrial PoE+ switch

 to the 

fiber network. TX, RX must be paired at both ends

. The 

optical 

port LED on the MC252

-4P-

1S

 

illuminates

 when 

the 

connection is established

 with a network device. 

Please refer to the LED indicators section for LED 

definitions

.  

8.  When all connections are set 

up

 

and the LEDs illuminate, 

the installation is complete. 

Troubleshooting 

This section contains 

issue

-solving 

inform

ation

. If the industrial

 

PoE+ switch 

is not functioning properly, 

en

sure th

at the 

industrial 

PoE+ switch 

was set up according to instructions in 

this manual.

 

 

Issue 

Solution 

The per port LED does 

not illuminate. 

Check the cable connection and try 

swapping out a cable.  

Performance is poor 

Check the speed duplex mode of the 

partner device. The industrial PoE+ 

switch is run in auto-negotiation mode 

and if the partner is set to half duplex, 

then the performance will be poor. 

The per port LED 

illuminates, but the 

traffic is irregular. 

Ensure that the attached device is not 

set to dedicated full duplex. Some 

devices use a physical or software 

switch to change duplex modes. Auto-

negotiation may not recognize this type 

of full-duplex setting. 

The industrial PoE+ 

switch doesn’t 

connect to the network 

Check the per port LED and/or try 

another port on the industrial PoE+ 

switch. Ensure that the cable is installed 

properly and is the correct type. Turn off 

the power and then, after a while, turn 

on the power again. 

Product specifications 

MC252-4P-1S 

Hardware specifications  

Fast Ethernet 

Copper Ports

 

 

Four

 

10/100BASE

-

TX RJ45 auto

-

MDI/MDI

-X ports  

PoE Inject

or Port 

Four

 ports 

with 802.3af/at PoE+ injector function

 

(Port

-1 to Port-4) 

SFP Port

 

One 100BASE

-

FX SFP port

 

Switch Architecture

 

S

tore-and-

Forward 

 

Switch Fabric

 

Gbps

/non-

blocking

 

Switch 

Throughput@64

 

bytes

 

0.74 

Mpps @64 bytes

 

MAC 

Address 

Table 

 

2K entries  

Flow Control 

 

IEEE 802.3x 

p

ause frame for full

-d

uplex

 

Back pressure for 

h

alf

-d

uplex

 

Jumbo Frame

 

10 Kbytes

 

DIP Switch (Po

rt-1 

to Port-4) 

Standard mode: 

30 W PoE transmission distance 

of 

100 

m at speed of 10

/100 

Mbps

VLAN mode: 

"Port-

based VLAN Protection" where 

ports can be isolated from each other via one DIP 

switch. 

Only Port

-5 can visit other ports.  

Extend mode: 

25 W PoE transmission 

distance of 

Содержание IFS MC252-4P-1S

Страница 1: ...rt MC252 4P 1S One 100BASE FX SFP interface One terminal block for master and slave power input Power Range 12 48 VDC redundant power Hardware DIP switch for Standard VLAN and Extend mode selection the Extend mode features a 25 W PoE transmission distance of 250 m at a speed of 10 Mbps Port 1 to Port 4 only Power over Ethernet Complies with IEEE 802 3at Power over Ethernet Plus end span PSE Backwa...

Страница 2: ...olarity 12 48 VDC power supply inputs for high availability applications Environmentally hardened design With the IP40 metal industrial case the industrial PoE switch provides a high level of immunity against electromagnetic interference and heavy electrical surges which are usually found on plant floors or in curb side traffic control cabinets without air conditioning It features a ventilated con...

Страница 3: ...t 5 of NS2052 4P 1T LED Color Function Link ACT Green Lit indicates the port is successfully connecting to the network at 10 or 100 Mbps Blinking indicates that the port is actively sending or receiving data Per 100FX SFP Slot Port 5 of MC252 4P 1S LED Color Function Link ACT Green Lit indicates the port is successfully connecting to the network at 100 Mbps Blinking indicates that the port is acti...

Страница 4: ...tors on the top and a minimum of three inches above and below the switch to allow for proper air flow This device uses a convection flow of hot air which rises and brings cold air in from the bottom and out of the top of the device Do not mount the switch horizontally as this does not allow air to flow up into the device and will result in damage to the switch Do not tie DC1 to DC2 DC2 is for seco...

Страница 5: ...iber network TX RX must be paired at both ends The optical port LED on the MC252 4P 1S illuminates when the connection is established with a network device Please refer to the LED indicators section for LED definitions 8 When all connections are set up and the LEDs illuminate the installation is complete Troubleshooting This section contains issue solving information If the industrial PoE switch i...

Страница 6: ... Power over Ethernet IEEE 802 3at Power over Ethernet Plus Environment Temperature Operating 40 to 75 C Storage 40 to 85 C Humidity 5 to 95 non condensing NS2052 4P 1T Hardware specifications Fast Ethernet Copper Ports Five 10 100BASE TX RJ45 auto MDI MDI X ports Port 1 to Port 5 PoE Injector Port Four ports with 802 3af at PoE injector function Port 1 to Port 4 Switch Architecture Store and Forwa...

Страница 7: ...ressure IEEE 802 3af Power over Ethernet IEEE 802 3at Power over Ethernet Plus Environment Temperature Operating 40 to 75 C Storage 40 to 85 C Humidity 5 to 95 non condensing Appendix Networking connection RJ45 pin assignments 1000Mbps 1000BASE T Contact MDI MDI X 1 BI_DA BI_DB 2 BI_DA BI_DB 3 BI_DB BI_DA 4 BI_DC BI_DD 5 BI_DC BI_DD 6 BI_DB BI_DA 7 BI_DD BI_DC 8 BI_DD BI_DC 10 100Mbps 10 100BASE T...

Страница 8: ...y information please check www firesecurityproducts com policy product warning or scan the following code Contact information and manuals tools firmware For contact information and to download the latest manuals tools and firmware go to the web site of your region Americas www interlogix com EMEA www firesecurityproducts com Manuals are available in several languages Australia New Zealand www utcf...

Страница 9: ... Products marked with this symbol cannot be disposed of as unsorted municipal waste in the European Union For proper recycling return this product to your local supplier upon the purchase of equivalent new equipment or dispose of it at designated collection points For more information see www recyclethis info Contact information North America T 1 855 286 8889 E techsupport interlogix com W www int...

Отзывы: