P/N 1073625-EN
• REV
A
• ISS 17APR19
3 / 9
LED indicators
System
LED
Color
Function
P1
Green
Lit
:
indicates power 1 has power.
P2
Green
Lit
:
indicates power 2 has power.
FAULT
Red
Lit
:
indicates either power 1 or power 2 has
no power.
30W
Orange
Off:
indicates the PoE
usage is less than 14
W.
Blinking:
indicates
that the PoE usage is
around 15
to 29 W.
Lights:
indicates
the PoE usage is
around
/over 30 W.
60W
Orange
Blinking:
indicates
that the PoE usage is
around 45
to 59 W.
Lit:
indicates
the PoE usage is around
/over
60 W.
90W
Orange
Blinking:
indicates
that the PoE usage is
around 75
to 89 W.
Lit:
indicates
the PoE usage is around
/over
90 W.
120W
Orange
Blinking:
indicates
that the PoE usage is
around
100 to 119 W.
Lit:
indicates
the PoE usage is at the
maximum.
Per 802.3at PoE+ 10/100BASE-TX Interface (Port 1 to Port
4)
LED
Color
Function
Link/ACT
Green
Lit
:
indicates the port
is successfully
connecting to the network at
10 Mbps or
100
Mbps.
Blinking
: indicate
s that the port
is actively
sending or receiving data.
PoE in
Use
Orange
Lit
:
indicates the port is providing DC in-line
power.
Off
:
indicates the connected device is not a
PoE powered device (PD)
.
Per 10/100BASE-TX Interface (Port 5 of NS2052-4P-1T)
LED
Color
Function
Link/ACT
Green
Lit
:
indicates the port
is successfully
connecting to the network at 10 or 100
Mbps.
Blinking
: indicate
s that the port
is actively
sending or receiving data.
Per 100FX SFP Slot (Port 5 of MC252-4P-1S)
LED
Color
Function
Link/ACT
Green
Lit
:
indicates the port
is successfully
connecting to the network at 100
Mbps.
Blinking
: indicate
s that the port
is actively
sending or receiving data.
Switch upper panel
The
upper panel of the industrial
PoE+ switch consist
s of
one
terminal block connector within
two DC power inputs
.
Figure
2
below
shows the
upper panel of
the
industrial
PoE+
switch.
Figure 2: Industrial PoE+ switch upper panel
Wiring the power inputs
The
six
-
contact terminal block connector on the top panel of
industrial
PoE+ switch
is used for two DC redundant
power
inputs. F
ollow
the steps below to insert the power wire.
Caution:
When performing procedures like inserting the wires
or tightening the wire-
clamp screws, ensure that
the power is
OFF to prevent
electrical shock.
1.
Insert positive
and negative DC power wires into contacts
1 and 2 for Power 1 or 5, and 6 for Power 2.
2. Tighten the wire-
clamp screws for preventing the
wires
from loosening.
1
2
3
4
5
6
Power 1
Fault
Power 2
+
-
+
-
Notes
:
1.
The wire gauge for the terminal block should be in the
range between 12 and 24 AWG.
2.
The DC power input range is 12
to 48
VDC
.