Classifying a PD according to its power consumption may assist a PoE system in optimizing its power distribution. 

Such a system typically suffers from lack of power resources, so that efficient power management based on 

classification results may reduce total system costs. 

5.3 Start-up 

Once line detection and optional classification stages are completed, the PSE must switch from low voltage to its full 

voltage capacity (44-57 Volts) over a minimal amount of time (above 15 microseconds). 

A gradual startup is required, as a sudden rise in voltage (reaching high frequencies) would introduce noise on the 

data lines. 

Once provision of power is initiated, it is common for inrush current to be experienced at the PSE port, due to the 

PD’s input capacitance. A PD must be designed to cease inrush current consumption (of over 350 mA) within 50 ms 

of power provision startup. 

5.4 Operation 

During normal operation, the PSE provides 44-57 VDC, able to support a minimum of 15.4 watts power. 

Power Overloads 

The IEEE 802.3af standard defines handling of overload conditions. In the event of an overload (a PD drawing a 

higher power level than the allowed 12.95 Watts), or an outright short circuit caused by a failure in cabling or in the 

PD, the PSE must shut down power within 50 to 75 milliseconds, while limiting current drain during this period to 

protect the cabling infrastructure. Immediate voltage drop is avoided to prevent shutdown due to random 

fluctuations. 

5.5 Power Disconnection Scenarios 

The IEEE 802.3af standard requires that devices powered over Ethernet be disconnected safely (i.e. power needs 

be shut down within a short period of time following disconnection of a PD from an active port). 

When a PD is disconnected, there is a danger that it will be replaced by a non-PoE-ready device while power is still 

on. Imagine disconnecting a powered IP phone utilizing 48 VDC, then inadvertently plugging the powered Ethernet 

cable into a non-PoE notebook computer. What’s sure to follow is not a pretty picture. 

The standard defines two means of disconnection, DC Disconnect and AC Disconnect, both of which provide the 

same functionality - the PSE shutdowns power to a disconnected port within 300 to 400ms. The upper boundary is 

a physical human limit for disconnecting one PD and reconnecting another. 

DC Disconnect 

DC Disconnect detection involves measurement of current. Naturally, a disconnected PD stops consuming current, 

which can be inspected by the PSE. The PSE must therefore disconnect power within 300 to 400 ms from the 

current flow stop. The lower time boundary is important to prevent shutdown due to random fluctuations. 

AC Disconnect 

This method is based on the fact that when a valid PD is connected to a port, the AC impedance measured on its 

terminals is significantly lower than in the case of an open port (disconnected PD). 

Содержание IFS ES2001-4P-4T

Страница 1: ...P N 1072680 REV A ISS 09MAY14 IFS ES2001 4P 4T User Manual...

Страница 2: ...ate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications You are cautioned that any changes or modifica...

Страница 3: ...10 2 7 Product Application 11 2 7 1 Connecting end node or switch 11 2 7 2 Typical Uses 12 2 8 Examples of Power over Ethernet Powered Device 13 3 SWITCH OPERATION 14 3 1 Address Table 14 3 2 Learnin...

Страница 4: ...ction Scenarios 20 DC Disconnect 20 AC Disconnect 20 6 TROUBLESHOOTING 22 APPENDIX A NETWORKING CONNECTION 23 A 1 DATA OUT PoE Switch RJ 45 Port Pin Assignments Port 1 to Port 4 23 A 2 Switch s RJ 45...

Страница 5: ...addresses Automatic address learning and address aging Supports Auto MDI MDI X function LED indicators for easy network diagnostic Ethernet standards comply with IEEE 802 3 Ethernet IEEE 802 3u Fast E...

Страница 6: ...Type End Span PoE Power Output Per Port 48V DC 350mA Max 15 4 watts Power Pin Assignment 1 2 3 6 Power Budget 55 watts Standard Conformance EMI Safety FCC Class A CE Operating environment 0 50 degree...

Страница 7: ...ES2001 4P 4T also provides a simple cost effective and highly reliable network connection for data as well as power Furthermore it is the ideal device for bridging among Ethernet Fast Ethernet workgr...

Страница 8: ...l not work till it is powered If your network is system critical please consider using UPS Uninterrupted Power Supply for your device to help prevent data loss or network downtime In some areas instal...

Страница 9: ...ktop Installation To install the Switch on desktop simply follow the next steps Step 1 Attach the rubber feet to the recessed areas on the bottom of the Switch as shown in Figure 2 3 Figure 2 3 Attach...

Страница 10: ...Place your Fast Ethernet Switch on a hard flat surface with the front panel positioned towards your front side Step 2 Attach a rack mount bracket to each side of the Switch with supplied screws attac...

Страница 11: ...surface or fasten the mounting brackets purchased separately with the provided screws in a standard 19 rack 2 Connect the power cord to the power inlet socket of ES2001 4P 4T and the other end into th...

Страница 12: ...UTP Category 5 cable or better Data Grade cabling Use of CAT3 or CAT4 cables with 100Mbps may cause data loss 2 7 2 Typical Uses Providing up to 4 PoE in line power interfaces the Switch can easily bu...

Страница 13: ...ere UPS is installed for un interrupt power system and power control system 6 12 watts Wireless LAN Access Points Museum Sightseeing Airport Hotel Campus Factory Warehouse can install the Access Point...

Страница 14: ...rward is one type of packet forwarding techniques A Store and Forward Ethernet Switching stores the incoming frame in an internal buffer do the complete error checking before transmission Therefore no...

Страница 15: ...ser Manual 15 Reset Detecting the modes does this and speeds at the second of both devices are connected and capable of both 10Base T and 100Base TX devices can connect with the port in either Half or...

Страница 16: ...an device is placed between legacy switch and the powered device Mid Span is tap the unused wire pairs 4 5 and 7 8 to carry power the other four is for data transmit End Span End Span device is direct...

Страница 17: ...and 6 and the pair on pins 1 and 2 can be of either polarity Power Sourcing Equipment PSE Powered Device PD DC DC Converter Spare Pair Figure 2 Power Supplied over the Data Pins When to install PoE Co...

Страница 18: ...and business access systems throughout the facility but they would rather avoid another electrician s payment References IEEE Std 802 3af 2003 Amendment to IEEE Std 802 3 2002 including IEEE Std 802 3...

Страница 19: ...red device has the correct signature resistance of 15 33 K 2 7 10 0 1 8 10 0 Classification Measure which power level class the resistor indicates 14 5 20 5 12 5 25 0 Startup Where the powered device...

Страница 20: ...urrent drain during this period to protect the cabling infrastructure Immediate voltage drop is avoided to prevent shutdown due to random fluctuations 5 5 Power Disconnection Scenarios The IEEE 802 3a...

Страница 21: ...48 VDC operating voltage The returned AC signal amplitude is monitored by the PSE at the port terminals During normal operation the PD s relatively low impedance lowers the returned AC signal while a...

Страница 22: ...Auto negotiation may not recognize this type of full duplex setting Why the Switch doesn t connect to the network Solution Check the LNK ACT LED on the switch Try another port on the Switch Make sure...

Страница 23: ...n Assignments Port 1 to Port 4 PIN NO RJ 45 SIGNAL ASSIGNMENT 1 Output Transmit Data Power 2 Output Transmit Data Power 3 Receive Data Power 4 5 6 Receive Data Power 7 8 A 2 Switch s RJ 45 Pin Assignm...

Страница 24: ...Brown 1 White Orange 2 Orange 3 White Green 4 Blue 5 White Blue 6 Green 7 White Brown 8 Brown SIDE 2 Straight Cable SIDE 1 SIDE2 SIDE 1 1 White Orange 2 Orange 3 White Green 4 Blue 5 White Blue 6 Gre...

Страница 25: ...Please make sure you have the requested diagnostic or log files ready before you contact us by phone or go to www interlogix com customer support Technical Support Europe Middle East and Africa W Sel...

Отзывы: