P/N 466-

2914 • REV C • ISS 15MAR19 

 

5 / 6 

the cable must be moved accordingly, before you screw in the 
detector. Do not place the housing cover on the detector until 
you have finished the teach-in procedure (see "Configuration" 
section); otherwise, the LEDs that are needed for the teach-in 
procedure will no longer be visible. 

After you put the housing cover on, seal both detector 
components with the supplied stickers. 

When connecting the wires, make sure that the command 
wires are either insulated or connected to a fixed potential, to 
prevent undesired execution of commands. Also make sure 
that solely the installation contractor has access to the 
command wire. Thus it must not be laid to the alarm control 
unit. 

The detector is encapsulated so that it meets protection class 
IP 67, in accordance with IEC 529. The switch for removal 
protection also has the same protection class. 

Configuration 

Note: 

To configure the detector, it has to be connected to a 

power supply. 

Basics 

– command types 

The grade 4 magnetic detector has three different commands: 

• 

Learn-in the unit to the environment 

• 

Learn -in the unit to the magnet 

• 

Reset all values 

All commands are triggered by a brief connection of the 
command wire to the z

ero potential (“contact ground”). 

Figure 11: Overview of learning phases 

 

Standard learn-in procedure 

Both learn-in commands must be executed to learn-in the 
detector. 

Learning-in the unit to the installation environment 

Before learning the unit to the environment, make sure that 
there are no devices or objects in the immediate vicinity of the 
magnetic switch which could create a strong magnetic field and 
disturb the detector in performing its functions. The magnet 
that belongs to the detector may also not be located within the 
immediate vicinity when you learn-in the detector to the 
environment.  

Note: 

You can only learn-in the detector to the environment 

when it is in the “Detector Reset” state. To reset the detector, 
proceed as described in the “Resetting the detector” section. 

To learn-in the unit to the installation environment: 

1.  Contact the command wire to ground to activate the learn-

in procedure for the environment. 

2.  The LED lights up red for several seconds to indicate that 

the 

“Learn-in Environment” command was selected. 

3.  The LED then starts to flash red for several seconds. 

Contact the command wire to ground again to confirm the 
command. If you do not want to execute the command, let 
the confirmation time elapse. 

4.  If you confirm the command in time, the LED stops 

flashing. The detector switches to the “Environment 
Learnt-

In” state, in which you can learn-in the unit to the 

magnet. 

Learning-in the unit to the magnet 

You can only learn-in the detector to the magnet when it is in 
the “Environment Learnt-In” state. To learn-in the detector to 
the environment, proceed as described in the 

“Learning-in the 

unit to the environment” section. 

If an error occurred during the learn-in process of the unit to 
the environment, the detector can be reset without having to 
first learn-in the unit to the magnet. 

This can be achieved by a brief disconnection of the power-
supply. Afterwards, proceed according to the 

“Learning-in the 

unit 

to the installation environment” section. 

Note: 

The magnet must already be correctly installed at this 

time. To improve visibility of the LED while selecting this 
command, you can hold the magnet outside of its closed 
position (open window/ door). In this case, be ready to 
immediately return the magnet to its closed position when 
required to do so. 

To learn-in the unit to the magnet: 

1.  Contact the command wire to ground to activate the learn-

in procedure for the magnet. 

2.  The LED lights up green for several seconds to indicate 

that the “Learn-In Magnet” command was selected. 

3.  The LED then starts to flash green for several seconds. 

Contact the command wire to ground again to confirm the 
command. If you do not want to execute the command, let 
the confirmation time elapse. 

4.  If you confirm the command in time, the LED flashes more 

quickly. Now return the magnet to its closed position (if it is 
not already in that position). If the requirements are met, 
the detector switches to the “Magnet Learnt-In” state, in 
which the monitoring of the mag- net position and the 
signal outputs are activated. 

5.  A red lamp indicates that the magnet was incorrectly 

positioned or that the magnetic field is too small due to 
other reasons. In this case, the detector remains in the 
“Environment Learnt-In” state, and the unit must be learnt-
in to the magnet again. 

Resetting the detector 

A detector reset is required when you need to update the 
previously learnt-in data or adjust the detector to a new magnet 
or installation situation. 

Note: 

Once you reset the detector, all changes you made are 

lost. 

Temporarily disconnect 

Power Supply

 

LED off

 

 

Reset Detector

 

Indication: Orange

 

Learn-In Environment

 

Indication: Red

 

Detector Reset

Default State: LED off

Environment 

-In

Learnt

LED off

 

Magnet

-In

Learnt

Detection Active: LED off

Learn

 

-In Magnet

 

Indication: Green

 

Содержание DC418

Страница 1: ... 2019 UTC Fire Security Americas Corporation Inc 1 of 6 P N 466 2914 REV C ISS 15MAR19 DC418 Magnetic Contact Operation and Installation Manual EN 1 2 Z Y X ...

Страница 2: ...2 of 6 P N 466 2914 REV C ISS 15MAR19 3 4 5 6 7 8 ...

Страница 3: ...BK YE GN BN WH GY Intrusion zone Tamper zone Burglar Alarm System y Intrusion internal zone D 418 C Intrusion External Field Fault D 418 C BK YE GN BN WH GY Rx Termination Resistor Intrusion zone Tamper zone Burglar Alarm System y BU PK RD 12 24 V DC Command input Tampering Removal Protection DC418 DC418 ...

Страница 4: ...s before you begin with the installation Item No Description A 1 Magnetic detector AMK 100 B 1 Magnet AMK 100 C 1 Detector Cover D 1 Magnet Cover E 2 Spacer Disk F 1 Spacer Disk Large G 1 Spacer Disk Magnet H 1 Mounting Bracket J 1 Countersunk Screw M4x12 K 1 Countersunk Sheet Metal Screw 3 5x19 L 2 Dome Head Screw M3x18 M 2 Dome Head Screw M3x8 N 2 Dome Head Screw M3x4 O 2 Dome Head Sheet Metal S...

Страница 5: ...ecute the command let the confirmation time elapse 4 If you confirm the command in time the LED stops flashing The detector switches to the Environment Learnt In state in which you can learn in the unit to the magnet Learning in the unit to the magnet You can only learn in the detector to the magnet when it is in the Environment Learnt In state To learn in the detector to the environment proceed a...

Страница 6: ...5 mm Signal output Electronic switch Transfer resistance closed approx 7 Ω typical Transfer resistance open 10 MΩ Electrical isolation between input and output min 30 V Permitted output current max 50 mA Permitted output voltage max 30 V Measurement speed approx 100 ms Connection cable LIYY9x0 14 mm copper tin plated Cable conductors See Table 1 Cable diameter Ø 5 8 mm Cable length Up to 10 m Cont...

Отзывы: