The menu selections will scroll automatically.  The other messages are shown below.  For further details regarding the 
functions, please refer to the page indicated. 

 

0=Set Tone ............................. Page 8 
1=Master Mode 
2=Service Check .................... Page 13 
3=Alarm Memory .................... Page 9 
44=Test................................... Page 9 
45=Display Test 
46=Light Control ..................... Page 9 
49=Spanish............................. Page 10 
5=User PIN ............................. Page 10 
6=User Authority..................... Page 10 
7=Detector Reset.................... Page 11 
90=Log Review....................... Page 7 
91=View Settings.................... Page 5 
97=Set Date/Time................... Page 8 
CHIME=Walk Test .................. Page 11 
EXIT=Silent Exit 

 

 

9 1  ADJUSTING THE VIEW / BRIGHTNESS OF THE LCD 

1)  Enter [

r

]-[

9

]-[

1

The LCD Screen will prompt “Please Enter Your Code". 

2)  Enter [

master code

The LCD will now prompt you to raise or lower the viewing angle.  Using the scroll 
keys to the right of the LCD, you can raise or lower the viewing angle of the text. 

 

3) To advance to the 

Brightness option, press 

 [

r

The LCD will prompt you to brighten or dim the LCD lighting.  Use the scroll keys 
again to adjust to desired brightness.  When completed, exit by pressing 

 [

r

]. 

 
 

r

 9 2 

PROGRAMMING CUSTOM MESSAGES IN THE KEYPAD 

NOTES

: The messages (custom, zone, and shutdown) are transferred to other LCD keypads after this mode is exited. 

 

All keypads must be addressed and enrolled for this to happen

.

 Set the keypad numbers with [

r

]-[9]-[4] prior to 

programming custom messages. If a keypad is added after messages are programmed, you should either program 

ALL

 messages in it, or enter custom message programming on an existing keypad and make changes. This is to 

prevent accidentally overwriting existing messages. See [

r

]-[9]-[3] option to prevent overwriting the custom message 

only. 
 

1)  Enter [

r

]-[

9

]-[

2

The LCD Screen will prompt “Please Enter Your Code".

 

2)  Enter [

program code

The LCD will now prompt you to enter message number followed by [

#

].  Zones 1 

through 192 custom messages are message numbers 1-192 respectively. 
Message 193 - Custom message top line. 
Message 194 - Custom message bottom line. 
Message 195 - Shutdown message top line. 
Message 196 - Shutdown message bottom line.  

3) Enter message number 

to edit followed by [

#

The LCD will display the zone number on the top line and the description will be 
shown on the bottom line. Use the instructions on page 2 for editing character data. 
To proceed to the next location, press the 

[Police]

 key.  To return to the previous 

location, press the 

[Fire]

 key.  To re-enter the last location, press the 

[Auxiliary]

 

key. 

4) When completed, exit by pressing [

EXIT

] while the LCD screen is prompting for a zone message #.  Any 

changes will automatically be copied to all other LCD keypads in the system.  

NOTE

: If you desire an LCD 

keypad to have a different custom message, you must enable Custom Message Lock under the [

r

]-[

9

]-[

3

function. 

 

 

Содержание CADDX NX148-E

Страница 1: ...5 SET KEYPAD OPTIONS 6 SET KEYPAD NUMBER AND PARTITION 7 KEYPAD FUNCTIONS 7 READING THE EVENT LOG 7 SET ELAPSED INCREMENTS SINCE LAST AUTOTEST 8 SET SYSTEM TIME AND DATE 8 ADJUST KEYPAD TONE 8 VIEW Z...

Страница 2: ...the bottom line with the numbers 1 8 in the first 8 characters If the number appears this binary switch is on If a minus sign appears where the number should be this switch is off Toggle numbers on o...

Страница 3: ...RUMPUS STAIRS WINDOW BATHROOM DURESS HEAT MICROWAVE SAFE STORAGE WING BEAM EAST HOLDUP MOTION SENSOR STUDY WIRELESS BEDROOM EMERGENCY HOUSE NORTH SHOCK TAMPER YARD BUTTON EXIT INFRARED NURSERY SHOP T...

Страница 4: ...t to unique addresses prior to enrolling modules To enroll the modules enter the Program Mode of the NetworX control panel When the Program Mode is exited the control will enroll the devices The enrol...

Страница 5: ...keypad numbers with r 9 4 prior to programming custom messages If a keypad is added after messages are programmed you should either program ALL messages in it or enter custom message programming on an...

Страница 6: ...rt The current state of the option will be shown in the lower right corner of the display Press r to advance to the next option without making changes Otherwise follow the directions on the bottom lin...

Страница 7: ...on September 25th at 5 27 p m by user 75 The r shows that this event is not programmed to be reported to the central monitoring station POSSIBLE LOG MESSAGES 7 DISPLAY DESCRIPTION TXlobat Transmitter...

Страница 8: ...de Entry A code has been entered First Open First Open Reports when the first partition is disarmed Last Close Last Close Reports when the last partition is armed Sprnklr Sprinkler Instant sprinkler s...

Страница 9: ...r 4 6 The LCD Screen will prompt to Select Light Number 0 9 2 Enter the number of the device to edit The LCD will display the light number on the left On the right side of the display it will prompt...

Страница 10: ...X4 6 8 or 3 digit NX8E user number Remember to use leading zeros i e 03 or A003 for user 3 The LCD will now prompt you for the first in the following list of attributes PROMPTS 1 Outputs used Open Clo...

Страница 11: ...y To set the multi partition mode use the r 9 3 function and answer YES to the question Master keypad NOTE r 1 followed by a code will temporarily access the Master Mode The keypad will revert back to...

Страница 12: ...ash Area Ready to Force Arm Dash Flashing Area Armed Instant Area Dash Area Disarmed Ready to Arm Dash Area Area is Armed To disarm all of the areas press the up scroll key To arm all of the areas pre...

Страница 13: ...this display press r 2 One or more of the following fault messages will be displayed Use the scroll keys to browse through them To exit the service messages press Control Over Current A short circuit...

Страница 14: ...an expansion device has been opened Expansion RF Jammed A radio receiver is being jammed Expansion Trouble An expansion device or keypad is not reporting to the control panel Expansion Siren trouble...

Страница 15: ...225 226 227 228 229 230 231 6 232 233 234 235 236 237 238 239 7 240 241 242 243 244 245 246 247 8 248 249 250 251 252 253 254 255 NX148 E MAXIMUM WIRE RUN Note These numbers are for one keypad at the...

Страница 16: ...0 degrees F CURRENT DRAW 110 mA Maximum 75 mA without Sounder LCD KEYPAD DIMENSIONS 6 4 Wide 5 3 High 1 0 Deep SHIPPING WEIGHT 2 lbs CADDX CONTROLS INC 1420 NORTH MAIN STREET GLADEWATER TEXAS 75647 TO...