Chapter 5: Menu reference
Advisor Advanced ATSx500A(-IP) Installation and Programming Manual
187
The entry timers can be programmed from 0 to 255 seconds. 0 means the timer
is not engaged and the alarm is activated immediately when entering the armed
premises. 255 and more means the time is infinite.
Note:
If zones are assigned to more then one area, the longest entry and exit
time is used. See “4 Zones and areas” on page 171.
4.2.n.3.1 Entry time 1
4.2.n.3.2 Entry time 2
Configure entry timers for entry/exit 1 and entry/exit 2 zone types. See “4.2.n.3
Entry time” on page 186 for details on entry timer programming.
4.2.n.3.3 PS Entry time 1
4.2.n.3.4 PS Entry time 2
Configure part set entry timers for entry/exit 1 and entry/exit 2 zone types.
Part set entry timers are configured the same way as full set entry timers. See
“4.2.n.3 Entry time” on page 186 for details on entry timer programming.
4.2.n.4 Other timers
1>Warning time
1
The menu groups additional area timers. See submenus below for details.
4.2.n.4.1 Warning time
1 Warning time
> <
Warning time is a period of time during which the automatic set procedure can be
postponed. After the warning time expires, the system is set.
The set postponing must be allowed in “4.2.n.5.2 Set retry” on page 188.
The warning timer can be programmed from 1 to 15 minutes.
4.2.n.4.2 Prealarm time
2 Prealarm time
> <
Every area has its own prealarm timer. When an alarm is triggered, it only
generates a local alarm, and the prealarm timer is started. If the local alarm is not
acknowledged during the prealarm time, the alarm is reported.
Note:
The entry zone must have activated option “4.1.n.6.14
described on page 176.
Use the PreAlarm time screen to set the prealarm time for the area. Each area
can be programmed with one prealarm time.
The prealarm timers can be programmed from 0 to 255 seconds.
Содержание ATS1500A-IP-LP
Страница 1: ...Advisor Advanced ATSx500A IP Installation and Programming Manual P N 466 2576 EN REV B ISS 16SEP16...
Страница 12: ...Chapter 1 Quick installation and programming 6 Advisor Advanced ATSx500A IP Installation and Programming Manual...
Страница 110: ...Chapter 3 System functions 104 Advisor Advanced ATSx500A IP Installation and Programming Manual...
Страница 300: ...Chapter 6 Software 294 Advisor Advanced ATSx500A IP Installation and Programming Manual...
Страница 306: ...Chapter 7 Troubleshooting 300 Advisor Advanced ATSx500A IP Installation and Programming Manual...
Страница 316: ...Chapter 8 Regulations 310 Advisor Advanced ATSx500A IP Installation and Programming Manual...
Страница 332: ...Appendix A Advisor Advanced events 326 Advisor Advanced ATSx500A IP Installation and Programming Manual...
Страница 348: ...Glossary 342 Advisor Advanced ATSx500A IP Installation and Programming Manual...