Wiring the CS350 control panel
Figure 8: Wiring the CS350 control panel
Wiring the HKC control panel
Figure 9: Wiring the HKC control panel
Battery replacement or removal
Caution:
Batteries can explode or cause burns
when incorrectly (dis)assembled or exposed to fire
or high temperatures.
Dispose of used battery according to battery directive
instructions and/or as required by local laws. Keep away from
children.
To replace batteries, disconnect the battery from the siren.
Only replace the battery with the recommended battery. Do not
use a different type of batteries. Use of any other batteries may
present a risk of fire or explosion.
Wiring the Advisor Advanced control panel
Figure 10: Wiring the Advisor Advanced control panel
Specifications
Voltage [1]
10.0 to 14.5 V (12 V nom.)
Standby current
LEDs off
LEDs on alt.
LEDs on cont.
38 mA
57 mA
74 mA
Operating current
(LEDs off) [2]
Sounder
Flash
S flash
350 mA
110 mA
420 mA
Sound output [2]
Average
Peak
112 dB(A) at 1 m
106 dB(A) at 3 m
119 dB(A) at 1 m
112 dB(A) at 3 m
Frequency
1.8 to 3 kHz
Sounder cut off timer
5 or 15 min
Working temperature
Without battery
With battery
−25 to +55°C
0 to +4
5°C
Dimensions
371 × 225 × 56 mm
Weight
1 kg
Recommended battery BS120N-XXL 12 V lead-acid battery
Beacon
Operating current
110 mA
Light output
100.000 peak lumens
Life time
1.000.000 flashes
Flash rate
1 Hz
Spike suppression
network
Standard fitted
All values are typical values measured at 12 V.
[1] To be connected to an external current limited supply. We
recommend using a 5 A power supply.
[2] Using only one piezo saves 120 mA current consumption when
the sounder is activated (sound output will drop by 4 dB).