![Interlogix Alliance AL-4017 Скачать руководство пользователя страница 20](http://html.mh-extra.com/html/interlogix/alliance-al-4017/alliance-al-4017_installation-manual_2076746020.webp)
Alliance AL-4017/AL-4617 Control Panel
Installation Manual
10
Control panel connections
Figure 9
shows the wiring connections on the control panel board. See
Battery capacity
on page 14 for the
appropriate battery type. To wire the panel, use these guidelines:
• The total auxiliary power output is 300 mA (inc12 on Comms) for the AL-4017 and 3 Amps
(inc12 on Comms) for the AL-4617.
• Alarm output is 1 Amp total and the siren output must be programmed for DC output if a bell is used.
• You must install a 1k resistor across the external siren outputs.
• The first and last device on the system bus (Comms) must be terminated.
Figure 9. Controller wiring connections
~
AC (do not short circuit)
Battery
Auxiliary power
~
+
_
+
+
+
_
_
_
SW+
SW-
S+
S-
S+
S-
+
_
+12
0V
D+
D-
T
C
External siren output
Internal siren output (8 ohm 15 watt)
Strobe output (MPI - 35 or EQ)
Comms (system bus)
Tamper input
Bell relay output
AL-4017
NEG
C
POS
(dry contacts)
AL-4617
NC
C
NO
24 VAC, AL-1690 transformer kit for AL-4017/
18 VAC, AL-1672 transformer kit for AL-4617
1k
+
Ademco
AB12M
Grade A
Alliance keypad
or other (bus, LAN
comm) device
* For UL installations this
terminal must not be used
due to the proximity to the
battery connection (< 1/4 in.)
*
Содержание Alliance AL-4017
Страница 1: ...Alliance AL 4017 AL 4617 Control Panel Installation Manual ...
Страница 6: ...Alliance AL 4017 AL 4617 Control Panel Installation Manual vi ...
Страница 8: ...Alliance AL 4017 AL 4617 Control Panel Installation Manual viii ...
Страница 10: ...Alliance AL 4017 AL 4617 Control Panel Installation Manual x ...